{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T19:06:16Z","timestamp":1780340776419,"version":"3.54.1"},"reference-count":15,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal-cot.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Orthopaedics and Trauma"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1016\/j.jcot.2026.103451","type":"journal-article","created":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T23:21:39Z","timestamp":1776468099000},"page":"103451","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Biomechanical comparison of tendon graft suturing techniques in arthroscopic ligament reconstruction using a novel knotless method in a cadaveric model"],"prefix":"10.1016","volume":"77","author":[{"given":"Killi Madhu","family":"Babu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"Gipson Samuel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-5362-7817","authenticated-orcid":false,"given":"Anirudh","family":"Dwajan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deepak Ranjan","family":"Patro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"6","key":"10.1016\/j.jcot.2026.103451_bib1","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1177\/1941738118803616","article-title":"Trends in incidence of ACL reconstruction and concomitant procedures among commercially insured individuals in the United States, 2002-2014","volume":"10","author":"Herzog","year":"2018","journal-title":"Sport Health"},{"issue":"16","key":"10.1016\/j.jcot.2026.103451_bib2","doi-asserted-by":"crossref","first-page":"1331","DOI":"10.2106\/JBJS.16.00595","article-title":"The burden of musculoskeletal conditions","volume":"98","author":"Weinstein","year":"2016","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"10.1016\/j.jcot.2026.103451_bib3","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/s00402-017-2830-8","article-title":"Superior biomechanical properties and tying time with the modified prusik knot and wittstein suture loop compared with the krackow stitch","volume":"138","author":"Hong","year":"2018","journal-title":"Arch Orthop Trauma Surg"},{"issue":"5","key":"10.1016\/j.jcot.2026.103451_bib4","doi-asserted-by":"crossref","first-page":"764","DOI":"10.2106\/00004623-198668050-00020","article-title":"A new stitch for ligament-tendon fixation. Brief note","volume":"68","author":"Krackow","year":"1986","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"10.1016\/j.jcot.2026.103451_bib5","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/j.arthro.2007.11.020","article-title":"Krackow locking stitch versus nonlocking premanufactured loop stitch for soft-tissue fixation: a biomechanical study","volume":"24","author":"Deramo","year":"2008","journal-title":"Arthroscopy"},{"issue":"12","key":"10.1016\/j.jcot.2026.103451_bib6","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1016\/j.arthro.2010.05.013","article-title":"Krackow locking stitch versus locking premanufactured loop stitch for soft-tissue fixation: a biomechanical study","volume":"26","author":"White","year":"2010","journal-title":"Arthroscopy"},{"issue":"12","key":"10.1016\/j.jcot.2026.103451_bib7","doi-asserted-by":"crossref","first-page":"3003","DOI":"10.1177\/0363546514550989","article-title":"Biomechanical comparison of krackow locking stitch versus nonlocking loop stitch with varying number of throws","volume":"42","author":"Hahn","year":"2014","journal-title":"Am J Sports Med"},{"issue":"4","key":"10.1016\/j.jcot.2026.103451_bib8","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1007\/s00167-006-0176-9","article-title":"Modified prusik knot versus whipstitch technique for soft tissue fixation in anterior cruciate ligament reconstruction: a biomechanical analysis","volume":"15","author":"Krappinger","year":"2007","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"6","key":"10.1016\/j.jcot.2026.103451_bib9","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1016\/j.arthro.2015.01.011","article-title":"Evaluation of 3 needleless grasping suture techniques for soft-tissue graft fixation: a porcine biomechanical study","volume":"31","author":"Hong","year":"2015","journal-title":"Arthroscopy"},{"issue":"5","key":"10.1016\/j.jcot.2026.103451_bib10","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/j.arthro.2011.10.014","article-title":"The modified finger-trap suture technique: a biomechanical comparison of a novel suture technique for graft fixation","volume":"28","author":"Su","year":"2012","journal-title":"Arthroscopy"},{"issue":"11","key":"10.1016\/j.jcot.2026.103451_bib11","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1007\/s00402-016-2551-4","article-title":"Biomechanical comparison between the modified rolling-hitch and the modified finger-trap suture techniques","volume":"136","author":"Camarda","year":"2016","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.jcot.2026.103451_bib12","series-title":"StatPearls. Treasure Island, FL","article-title":"Suture hypersensitivity","author":"Titley-Diaz","year":"2026"},{"issue":"6","key":"10.1016\/j.jcot.2026.103451_bib13","doi-asserted-by":"crossref","first-page":"e2079","DOI":"10.1016\/j.eats.2017.08.031","article-title":"Hamstring graft preparation techniques for anterior cruciate ligament reconstruction","volume":"6","author":"Vinagre","year":"2017","journal-title":"Arthrosc Tech"},{"issue":"4","key":"10.1016\/j.jcot.2026.103451_bib14","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1007\/s43465-023-00847-0","article-title":"Peroneus longus graft harvest: a technique note","volume":"57","author":"Arora","year":"2023","journal-title":"Indian J Orthop"},{"issue":"2","key":"10.1016\/j.jcot.2026.103451_bib15","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1007\/s12565-019-00508-z","article-title":"Effects of different cadaver preservation methods on muscles and tendons: a morphometric, biomechanical and histological study","volume":"95","author":"Beger","year":"2020","journal-title":"Anat Sci Int"}],"container-title":["Journal of Clinical Orthopaedics and Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0976566226001189?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0976566226001189?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T18:39:49Z","timestamp":1780339189000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0976566226001189"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":15,"alternative-id":["S0976566226001189"],"URL":"https:\/\/doi.org\/10.1016\/j.jcot.2026.103451","relation":{},"ISSN":["0976-5662"],"issn-type":[{"value":"0976-5662","type":"print"}],"subject":[],"published":{"date-parts":[[2026,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical comparison of tendon graft suturing techniques in arthroscopic ligament reconstruction using a novel knotless method in a cadaveric model","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Orthopaedics and Trauma","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcot.2026.103451","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Delhi Orthopedic Association. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"103451"}}