{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T14:46:44Z","timestamp":1785854804515,"version":"3.56.0"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2005,3,1]],"date-time":"2005-03-01T00:00:00Z","timestamp":1109635200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2005,3]]},"DOI":"10.1016\/j.jcrs.2004.07.022","type":"journal-article","created":{"date-parts":[[2005,4,15]],"date-time":"2005-04-15T07:25:02Z","timestamp":1113549902000},"page":"534-542","source":"Crossref","is-referenced-by-count":26,"title":["Correlation between the measurement of posterior capsule opacification severity and visual function testing"],"prefix":"10.1097","volume":"31","author":[{"given":"Romina M.J.","family":"Jose","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lloyd E.","family":"Bender","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James F.","family":"Boyce","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Catherine","family":"Heatley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-25-20210210","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.1016\/S0886-3350(97)80022-3","article-title":"Photographic image analysis system of posterior capsule opacification.","volume":"23","author":"Tetz","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R2-25-20210210","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1016\/S0886-3350(97)80023-5","article-title":"High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery.","volume":"23","author":"Pande","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R3-25-20210210","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/S0886-3350(01)01228-7","article-title":"Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification.","volume":"28","author":"Buehl","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R4-25-20210210","doi-asserted-by":"crossref","first-page":"1614","DOI":"10.1016\/S0886-3350(98)80352-0","article-title":"Inhibition of posterior capsule opacification with an immunotoxin specific for lens epithelial cells: 24 month clinical results.","volume":"24","author":"Clark","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R5-25-20210210","first-page":"3882","article-title":"Quantification of posterior capsular opacification in digital images after cataract surgery.","volume":"41","author":"Barman","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R6-25-20210210","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1016\/S0886-3350(99)00259-X","article-title":"Posterior capsule opacification. Part 2: clinical findings.","volume":"25","author":"Tetz","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"R7-25-20210210","doi-asserted-by":"crossref","first-page":"2058","DOI":"10.1016\/j.jcrs.2004.05.010","article-title":"POCOman: new system for quantifying posterior capsule opacification.","volume":"30","author":"Bender","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R8-25-20210210","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/S0886-3350(02)01509-2","article-title":"Comparison of 4 methods for quantifying posterior capsule opacification.","volume":"29","author":"Findl","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R9-25-20210210","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1136\/bjo.83.8.902","article-title":"Automated localisation of the optic disc, fovea, and retinal blood vessels from digital colour fundus images.","volume":"83","author":"Sinthanayothin","year":"1999","journal-title":"Br J Ophthalmol"},{"key":"R11-25-20210210","doi-asserted-by":"crossref","first-page":"4665","DOI":"10.1167\/iovs.02-0634","article-title":"The effect of posterior capsule opacification on visual function.","volume":"44","author":"Meacock","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R12-25-20210210","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1016\/0042-6989(90)90096-4","article-title":"The intraocular straylight function in 129 healthy volunteers; dependence on angle, age and pigmentation.","volume":"30","author":"IJspeert","year":"1990","journal-title":"Vision Res"},{"key":"R13-25-20210210","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1007\/BF00142360","article-title":"Importance of pathological intraocular light scatter for visual disability.","volume":"61","author":"van den Berg","year":"1986","journal-title":"Doc Ophthalmol"},{"key":"R14-25-20210210","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement.","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335004008946?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335004008946?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.ovid.com\/10.1016\/j.jcrs.2004.07.022","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T13:48:05Z","timestamp":1785851285000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/02158034-200503000-00025"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,3]]},"references-count":13,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2005]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2004.07.022","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2005,3]]}}}