{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T16:32:24Z","timestamp":1785861144604,"version":"3.56.0"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2006,6,1]],"date-time":"2006-06-01T00:00:00Z","timestamp":1149120000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2006,6]]},"DOI":"10.1016\/j.jcrs.2006.02.018","type":"journal-article","created":{"date-parts":[[2006,6,29]],"date-time":"2006-06-29T13:50:10Z","timestamp":1151589010000},"page":"999-1006","source":"Crossref","is-referenced-by-count":32,"title":["Age-related behavior of posterior chamber lenses in myopic phakic eyes during accommodation measured by anterior segment partial coherence interferometry"],"prefix":"10.1097","volume":"32","author":[{"given":"Barbara A.M.","family":"Lege","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wolfgang","family":"Haigis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas F.","family":"Neuhann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus H.","family":"Bauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-30-20210210","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/S0886-3350(96)80215-X","article-title":"Posterior chamber myopia lenses in phakic eyes.","volume":"22","author":"Fechner","year":"1996","journal-title":"J Cataract Refract Surg"},{"key":"R3-30-20210210","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/S0886-3350(96)80007-1","article-title":"Collamer intraocular contact lens to correct high myopia.","volume":"22","author":"Assetto","year":"1996","journal-title":"J Cataract Refract Surg"},{"key":"R4-30-20210210","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1016\/j.ophtha.2004.03.026","article-title":"United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopia; three-year follow-up.","volume":"111","year":"2004","journal-title":"Ophthalmology"},{"key":"R5-30-20210210","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1016\/S0886-3350(98)80253-8","article-title":"Staar Collamer posterior chamber phakic intraocular lens to correct myopia and hyperopia.","volume":"24","author":"Rosen","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R7-30-20210210","doi-asserted-by":"crossref","first-page":"673","DOI":"10.3928\/1081-597X-20021101-03","article-title":"Incidence of lens opacities and clinically significant cataracts with the Implantable Contact Lens: comparison of two lens designs; the ICL in Treatment of Myopia (ITM) Study Group.","volume":"18","author":"Sanders","year":"2002","journal-title":"J Refract Surg"},{"key":"R8-30-20210210","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.1016\/S0886-3350(98)80361-1","article-title":"Cataract formation after posterior chamber phakic intraocular lens implantation.","volume":"24","author":"Trindade","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R9-30-20210210","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1016\/j.jcrs.2004.03.035","article-title":"Phakic posterior chamber intraocular lens for high myopia.","volume":"30","author":"Pineda-Fernandez","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R11-30-20210210","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/S0886-3350(01)01218-4","article-title":"Implantable contact lens for high myopia.","volume":"28","author":"Uusitalo","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R12-30-20210210","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1016\/S0886-3350(03)00065-8","article-title":"Implantable contact lens for moderate to high myopia; relationship of vaulting to cataract formation.","volume":"29","author":"Gonvers","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R13-30-20210210","doi-asserted-by":"crossref","first-page":"2269","DOI":"10.1016\/j.jcrs.2004.07.018","article-title":"Long-term results of implantation of phakic posterior chamber intraocular lenses.","volume":"30","author":"Lackner","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R14-30-20210210","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1117\/12.938523","article-title":"Ophthalmic laser interferometer.","volume":"658","author":"Fercher","year":"1986","journal-title":"Proc SPIE"},{"key":"R15-30-20210210","doi-asserted-by":"crossref","first-page":"6637","DOI":"10.1364\/AO.31.006637","article-title":"Measurement of corneal thickness by low-coherence interferometry.","volume":"31","author":"Hitzenberger","year":"1992","journal-title":"Appl Opt"},{"key":"R16-30-20210210","first-page":"1304","article-title":"Submicrometer precision biometry of the anterior segment of the human eye.","volume":"38","author":"Drexler","year":"1997","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R17-30-20210210","doi-asserted-by":"crossref","first-page":"2789","DOI":"10.1016\/S0042-6989(97)00066-7","article-title":"Biometric investigation of changes in the anterior eye segment during accommodation.","volume":"37","author":"Drexler","year":"1997","journal-title":"Vision Res"},{"key":"R18-30-20210210","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.ophtha.2003.05.013","article-title":"Effect of accommodation and pupil size on the movement of a posterior chamber lens in the phakic eye.","volume":"111","author":"Petternel","year":"2004","journal-title":"Ophthalmology"},{"key":"R20-30-20210210","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1016\/j.ajo.2004.06.009","article-title":"Position of angle-supported, iris-fixated, and ciliary sulcus-implanted myopic phakic intraocular lenses evaluated by Scheimpflug photography.","volume":"138","author":"Baumeister","year":"2004","journal-title":"Am J Ophthalmol"},{"key":"R21-30-20210210","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1007\/s00417-002-0551-2","article-title":"Monitoring accommodative ciliary muscle function using three-dimensional ultrasound.","volume":"240","author":"Stachs","year":"2002","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R22-30-20210210","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.survophthal.2005.08.011","article-title":"Phakic intraocular lenses.","volume":"50","author":"Lovisolo","year":"2005","journal-title":"Surv Ophthalmol"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335006001647?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335006001647?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.ovid.com\/10.1016\/j.jcrs.2006.02.018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T15:39:29Z","timestamp":1785857969000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/02158034-200606000-00030"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,6]]},"references-count":18,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2006]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2006.02.018","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2006,6]]}}}