{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:03:18Z","timestamp":1786118598661,"version":"build-2736575974"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2007,3,1]],"date-time":"2007-03-01T00:00:00Z","timestamp":1172707200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2007,3]]},"DOI":"10.1016\/j.jcrs.2006.11.012","type":"journal-article","created":{"date-parts":[[2007,2,23]],"date-time":"2007-02-23T11:36:58Z","timestamp":1172230618000},"page":"510-515","source":"Crossref","is-referenced-by-count":80,"title":["Corneal wound architecture and integrity after phacoemulsification"],"prefix":"10.1097","volume":"33","author":[{"given":"John P.","family":"Berdahl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John J.","family":"DeStafeno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Terry","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-36-20210210","doi-asserted-by":"crossref","first-page":"1456","DOI":"10.1016\/S0886-3350(96)80147-7","article-title":"Prospective evaluation of early visual and refractive effects with small clear corneal incision for cataract surgery.","volume":"22","author":"Lyle","year":"1996","journal-title":"J Cataract Refract Surg"},{"key":"R2-36-20210210","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1016\/j.jcrs.2003.07.011","article-title":"Optimizing refractive lens exchange with bimanual microincision phacoemulsification.","volume":"30","author":"Fine","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R3-36-20210210","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1097\/01.icu.0000193069.32369.e1","article-title":"Update on bimanual microincisional cataract surgery.","volume":"17","author":"Weikert","year":"2006","journal-title":"Curr Opin Ophthalmol"},{"key":"R4-36-20210210","doi-asserted-by":"crossref","first-page":"2342","DOI":"10.1016\/S0161-6420(03)00733-4","article-title":"Dynamic morphology of clear corneal cataract incisions.","volume":"110","author":"McDonnell","year":"2003","journal-title":"Ophthalmology"},{"key":"R5-36-20210210","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1001\/archopht.123.5.643","article-title":"Ingress of India ink into the anterior chamber through sutureless clear corneal cataract wounds.","volume":"123","author":"Taban","year":"2005","journal-title":"Arch Ophthalmol"},{"issue":"suppl 2","key":"R6-36-20210210","doi-asserted-by":"crossref","first-page":"S62","DOI":"10.1016\/j.survophthal.2004.01.003","article-title":"Dynamic morphology of sutureless cataract woundseffect of incision angle and location.","volume":"49","author":"Taban","year":"2004","journal-title":"Surv Ophthalmol"},{"key":"R7-36-20210210","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1146\/annurev.micro.55.1.105","article-title":"Big bacteria.","volume":"55","author":"Schulz","year":"2001","journal-title":"Annu Rev Microbiol"},{"key":"R9-36-20210210","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1046\/j.1442-9071.2001.d01-20.x","article-title":"Endophthalmitis in the western Sydney region: a case-control study.","volume":"29","author":"Lertsumitkul","year":"2001","journal-title":"Clin Exp Ophthalmol"},{"key":"R10-36-20210210","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/S0886-3350(02)01483-9","article-title":"Bacterial endophthalmitis after small-incision cataract surgery; effect of incision placement and intraocular lens type.","volume":"29","author":"Nagaki","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R12-36-20210210","doi-asserted-by":"crossref","first-page":"1562","DOI":"10.1001\/archopht.1991.01080110098044","article-title":"Infectious endophthalmitis following sutureless cataract surgery.","volume":"109","author":"Stonecipher","year":"1991","journal-title":"Arch Ophthalmol"},{"key":"R13-36-20210210","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1016\/S0002-9394(14)71805-7","article-title":"Total detachment of Descemets membrane after small-incision cataract extraction.","volume":"114","author":"Macsai","year":"1992","journal-title":"Am J Ophthalmol"},{"key":"R15-36-20210210","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1016\/j.jcrs.2005.03.051","article-title":"Clear corneal paracentesis: a case of chronic wound leakage in a patient having bimanual phacoemulsification.","volume":"31","author":"Stratas","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R16-36-20210210","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1016\/S0886-3350(02)01276-2","article-title":"Microphacoemulsification with WhiteStar; a wound-temperature study.","volume":"28","author":"Soscia","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R17-36-20210210","doi-asserted-by":"crossref","first-page":"2199","DOI":"10.1016\/S0886-3350(03)00330-4","article-title":"Feasibility of sleeveless bimanual phacoemulsification with the Millennium microsurgical system.","volume":"29","author":"Braga-Mele","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R18-36-20210210","doi-asserted-by":"crossref","first-page":"934","DOI":"10.1016\/S0886-3350(01)00822-7","article-title":"Feasibility of ultrasound cataract surgery with a 1.4 mm incision.","volume":"27","author":"Tsuneoka","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R20-36-20210210","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1016\/S0886-3350(02)01917-X","article-title":"Efficacy and wound-temperature gradient of Whitestar phacoemulsification through a 1.2 mm incision.","volume":"29","author":"Donnenfeld","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R21-36-20210210","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1016\/S0886-3350(02)01277-4","article-title":"Bimanual phacoemulsification through 2 stab incisions; a wound-temperature study.","volume":"28","author":"Soscia","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R22-36-20210210","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/S0886-3350(01)01235-4","article-title":"Ultrasonic phacoemulsification using a 1.4 mm incision: clinical results.","volume":"28","author":"Tsuneoka","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R24-36-20210210","doi-asserted-by":"crossref","first-page":"1997","DOI":"10.1016\/j.ophtha.2005.06.024","article-title":"Outcomes of microincision cataract surgery versus coaxial phacoemulsification.","volume":"112","author":"Alio","year":"2005","journal-title":"Ophthalmology"},{"key":"R25-36-20210210","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.1016\/j.jcrs.2005.01.026","article-title":"Retinal image quality after microincision intraocular lens implantation.","volume":"31","author":"Alio","year":"2005","journal-title":"J Cataract Refract Surg"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335007000065?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335007000065?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.ovid.com\/10.1016\/j.jcrs.2006.11.012","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T16:28:29Z","timestamp":1786033709000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/02158034-200703000-00036"}},"subtitle":["Evaluation of coaxial, microincision coaxial, and microincision bimanual techniques"],"short-title":[],"issued":{"date-parts":[[2007,3]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2007]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2006.11.012","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2007,3]]}}}