{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:03:43Z","timestamp":1786118623810,"version":"build-2736575974"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2007,5,1]],"date-time":"2007-05-01T00:00:00Z","timestamp":1177977600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2007,5]]},"DOI":"10.1016\/j.jcrs.2007.01.020","type":"journal-article","created":{"date-parts":[[2007,4,27]],"date-time":"2007-04-27T07:13:59Z","timestamp":1177658039000},"page":"796-799","source":"Crossref","is-referenced-by-count":13,"title":["Capsulorhexis contraction after cataract surgery: Comparison of sharp anterior edge and modified anterior edge acrylic intraocular lenses"],"prefix":"10.1097","volume":"33","author":[{"given":"Charlotte","family":"Corydon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Lindholt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ellen B.","family":"Knudsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jesper","family":"Graakjaer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas J.","family":"Corydon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mikael","family":"Dam-Johansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-27-20210210","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0886-3350(13)80870-X","article-title":"Development, advantages, and methods of the continuous circular capsulorhexis technique.","volume":"16","author":"Gimbel","year":"1990","journal-title":"J Cataract Refract Surg"},{"key":"R2-27-20210210","doi-asserted-by":"crossref","first-page":"1362","DOI":"10.1016\/S0886-3350(99)00227-8","article-title":"Capsule contraction after continuous curvilinear capsulorhexis: poly(methyl methacrylate) versus silicone intraocular lenses.","volume":"25","author":"Cochener","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"R3-27-20210210","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/S0002-9394(14)70169-2","article-title":"Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation.","volume":"123","author":"Hayashi","year":"1997","journal-title":"Am J Ophthalmol"},{"key":"R4-27-20210210","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/S0886-3350(13)80340-9","article-title":"Postoperative complications of capsulorhexis.","volume":"19","author":"Masket","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R5-27-20210210","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.1016\/S0886-3350(98)80018-7","article-title":"Measuring the anterior capsule opening after cataract surgery to assess capsule shrinkage.","volume":"24","author":"Kimura","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R6-27-20210210","doi-asserted-by":"crossref","first-page":"1613","DOI":"10.1016\/S0886-3350(02)01378-0","article-title":"Changes in the area of the anterior capsule opening after intraocular lens implantation.","volume":"28","author":"Park","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R7-27-20210210","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1016\/S0886-3350(02)01371-8","article-title":"Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification.","volume":"28","author":"Buehl","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R8-27-20210210","doi-asserted-by":"crossref","first-page":"1875","DOI":"10.1016\/j.jcrs.2004.01.042","article-title":"Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction.","volume":"30","author":"Sacu","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R9-27-20210210","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.1016\/S0886-3350(02)01427-X","article-title":"Comparison of AcrySof MA30BA and Sensar AR40 acrylic intraocular lenses.","volume":"28","author":"Casprini","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R10-27-20210210","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/S0886-3350(97)80346-X","article-title":"Change in capsulorhexis size after implantation of three types of intraocular lenses.","volume":"23","author":"Gonvers","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R11-27-20210210","doi-asserted-by":"crossref","first-page":"1532","DOI":"10.1016\/S0886-3350(97)80025-9","article-title":"Anterior capsule stability in eyes with intraocular lenses made of poly(methyl methacrylate), silicone, and AcrySof.","volume":"23","author":"Ursell","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R12-27-20210210","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1016\/j.ophtha.2004.11.013","article-title":"Intraocular lens factors that may affect anterior capsule contraction.","volume":"112","author":"Hayashi","year":"2005","journal-title":"Ophthalmology"},{"key":"R13-27-20210210","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.1136\/bjo.82.12.1429","article-title":"Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome.","volume":"82","author":"Hayashi","year":"1998","journal-title":"Br J Ophthalmol"},{"key":"R14-27-20210210","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1016\/S0161-6420(98)97028-2","article-title":"Anterior capsule contraction and intraocular lens dislocation after implant surgery in eyes with retinitis pigmentosa.","volume":"105","author":"Hayashi","year":"1998","journal-title":"Ophthalmology"},{"key":"R15-27-20210210","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/S0886-3350(01)00901-4","article-title":"Risk factors for contraction of the anterior capsule opening after cataract surgery.","volume":"28","author":"Kato","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R16-27-20210210","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/S0886-3350(98)80325-8","article-title":"Adhesiveness of AcrySof to a collagen film.","volume":"24","author":"Nagata","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R17-27-20210210","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1136\/bjo.80.5.469","article-title":"In vivo human lens epithelial cell proliferation on the anterior surface of PMMA intraocular lenses.","volume":"80","author":"Pande","year":"1996","journal-title":"Br J Ophthalmol"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335007002507?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335007002507?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.ovid.com\/10.1016\/j.jcrs.2007.01.020","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T16:33:04Z","timestamp":1786033984000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/02158034-200705000-00027"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,5]]},"references-count":17,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2007]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2007.01.020","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2007,5]]}}}