{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T19:38:58Z","timestamp":1769110738080,"version":"3.49.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","license":[{"start":{"date-parts":[[2008,8,1]],"date-time":"2008-08-01T00:00:00Z","timestamp":1217548800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2008,8]]},"DOI":"10.1016\/j.jcrs.2008.04.018","type":"journal-article","created":{"date-parts":[[2008,7,24]],"date-time":"2008-07-24T09:16:26Z","timestamp":1216890986000},"page":"1362-1366","source":"Crossref","is-referenced-by-count":18,"title":["Effect of a new cohesive ophthalmic viscosurgical device on corneal protection and intraocular pressure in small-incision cataract surgery"],"prefix":"10.1097","volume":"34","author":[{"given":"Thomas","family":"Neumayer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ana","family":"Prinz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Findl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-36-20210210","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0886-3350(96)80272-0","article-title":"Long-term endothelial cell loss following phacoemulsification through a temporal clear corneal incision.","volume":"22","author":"Dick","year":"1996","journal-title":"J Cataract Refract Surg"},{"key":"R2-36-20210210","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1016\/S0886-3350(98)80049-7","article-title":"Endothelial damage with cataract surgery techniques.","volume":"24","author":"Diaz-Valle","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R3-36-20210210","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1038\/eye.1990.53","article-title":"The corneal endothelium.","volume":"4","author":"Tuft","year":"1990","journal-title":"Eye"},{"key":"R4-36-20210210","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1016\/j.ophtha.2003.09.027","article-title":"Central corneal thickness measurements with partial coherence interferometry, ultrasound, and the Orbscan system.","volume":"111","author":"Rainer","year":"2004","journal-title":"Ophthalmology"},{"key":"R5-36-20210210","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.jcrs.2005.12.138","article-title":"Comparison of central corneal thickness measurements with a new optical device and a standard ultrasonic pachymeter.","volume":"32","author":"Nemeth","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R6-36-20210210","doi-asserted-by":"crossref","first-page":"1630","DOI":"10.1016\/S0886-3350(99)00244-8","article-title":"Randomized clinical comparison of Healon GV and Viscoat.","volume":"25","author":"Miller","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"R7-36-20210210","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1016\/S0886-3350(02)01745-5","article-title":"Corneal endothelial cell protection with a dispersive viscoelastic material and an irrigating solution during phacoemulsification: low-cost versus expensive combination.","volume":"29","author":"Kiss","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R8-36-20210210","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/S0002-9394(14)73923-6","article-title":"A comparison of corneal endothelial changes after use of Healon or Viscoat during phacoemulsification.","volume":"115","author":"Koch","year":"1993","journal-title":"Am J Ophthalmol"},{"key":"R9-36-20210210","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1016\/S0886-3350(97)80071-5","article-title":"Corneal endothelial function after extracapsular cataract extraction and phacoemulsification.","volume":"23","author":"Ravalico","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R10-36-20210210","doi-asserted-by":"crossref","first-page":"1505","DOI":"10.1016\/S0886-3350(00)00436-3","article-title":"Corneal thickness and visual acuity after phacoemulsification with 3 viscoelastic materials.","volume":"26","author":"Davis","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R11-36-20210210","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/S0886-3350(13)80214-3","article-title":"Clinical comparison of Provisc and Healon in cataract surgery.","volume":"21","author":"Lehmann","year":"1995","journal-title":"J Cataract Refract Surg"},{"key":"R12-36-20210210","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1001\/archopht.1988.01060140066026","article-title":"Positive correlation of corneal thickness and endothelial cell loss; serial measurements after cataract surgery.","volume":"106","author":"Cheng","year":"1988","journal-title":"Arch Ophthalmol"},{"key":"R13-36-20210210","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1001\/archopht.1986.01050240093047","article-title":"A comparison of the efficacy and toxicity of and intraocular pressure response to viscous solutions in the anterior chamber.","volume":"104","author":"Glasser","year":"1986","journal-title":"Arch Ophthalmol"},{"key":"R14-36-20210210","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/S0886-3350(13)80979-0","article-title":"Prospective comparison of the effects of Occucoat, Viscoat, and Healon on intraocular pressure and endothelial cell loss.","volume":"17","author":"Lane","year":"1991","journal-title":"J Cataract Refract Surg"},{"key":"R15-36-20210210","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1016\/S0886-3350(13)81050-4","article-title":"Protective effects of Healon and Occucoat against air bubble endothelial damage during ultrasonic agitation of the anterior chamber.","volume":"17","author":"Monson","year":"1991","journal-title":"J Cataract Refract Surg"},{"key":"R16-36-20210210","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1097\/ICO.0b013e3180cfe4f1","article-title":"Reliability of a video-based noncontact specular microscope for assessing the corneal endothelium.","volume":"26","author":"Prinz","year":"2007","journal-title":"Cornea"},{"key":"R17-36-20210210","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/S0886-3350(01)00994-4","article-title":"Revisiting early postoperative follow-up after phacoemulsification.","volume":"28","author":"Ahmed","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R18-36-20210210","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/0002-9394(83)90388-4","article-title":"Obstruction of aqueous outflow by sodium hyaluronate in enucleated human eyes.","volume":"95","author":"Berson","year":"1983","journal-title":"Am J Ophthalmol"},{"key":"R19-36-20210210","doi-asserted-by":"crossref","first-page":"1714","DOI":"10.1016\/j.ophtha.2005.05.011","article-title":"Natural course of intraocular pressure after cataract surgery with sodium chondroitin sulfate 4-sodium hyaluronate 3 (Viscoat).","volume":"112","author":"Rainer","year":"2005","journal-title":"Ophthalmology"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335008004690?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335008004690?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2008.04.018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,13]],"date-time":"2021-05-13T16:42:30Z","timestamp":1620924150000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-200808000-00036"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,8]]},"references-count":19,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2008]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2008.04.018","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2008,8]]}}}