{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T18:57:46Z","timestamp":1757703466870},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","license":[{"start":{"date-parts":[[2010,11,1]],"date-time":"2010-11-01T00:00:00Z","timestamp":1288569600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2010,11]]},"DOI":"10.1016\/j.jcrs.2010.05.017","type":"journal-article","created":{"date-parts":[[2010,10,27]],"date-time":"2010-10-27T08:32:14Z","timestamp":1288168334000},"page":"1862-1866","source":"Crossref","is-referenced-by-count":22,"title":["Comparative analysis of white-to-white and angle-to-angle distance measurements with partial coherence interferometry and optical coherence tomography"],"prefix":"10.1097","volume":"36","author":[{"given":"Gabor","family":"Nemeth","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ziad","family":"Hassan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eszter","family":"Szalai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andras","family":"Berta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laszlo","family":"Modis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R3-11-20210210","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1016\/S0886-3350(98)80253-8","article-title":"Staar Collamer posterior chamber phakic intraocular lens to correct myopia and hyperopia.","volume":"24","author":"Rosen","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R4-11-20210210","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.survophthal.2005.08.011","article-title":"Phakic intraocular lenses.","volume":"50","author":"Lovisolo","year":"2005","journal-title":"Surv Ophthalmol"},{"key":"R5-11-20210210","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/01.cco.0000188624.54743.c7","article-title":"Phakic intraocular lenses.","volume":"17","author":"Chang","year":"2006","journal-title":"Curr Opin Ophthalmol"},{"key":"R6-11-20210210","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.jcrs.2004.04.051","article-title":"Clinical results of ZSAL-4 angle-supported phakic intraocular lenses in 190 myopic eyes.","volume":"31","author":"Leccisotti","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R7-11-20210210","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1097\/00055735-200408000-00012","article-title":"Advances in phakic intraocular lenses: indications, efficacy, safety, and new designs.","volume":"15","author":"Alio","year":"2004","journal-title":"Curr Opin Ophthalmol"},{"key":"R8-11-20210210","doi-asserted-by":"crossref","first-page":"336","DOI":"10.3928\/1081-597X-20000501-07","article-title":"Relationship between anterior chamber depth, refractive state, corneal diameter, and axial length.","volume":"16","author":"Hosny","year":"2000","journal-title":"J Refract Surg"},{"key":"R9-11-20210210","doi-asserted-by":"crossref","first-page":"1982","DOI":"10.1016\/j.jcrs.2003.10.041","article-title":"Correlation between different measurements within the eye relative to phakic intraocular lens implantation.","volume":"30","author":"Werner","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R10-11-20210210","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.jcrs.2003.06.004","article-title":"Comparison of manual and automated methods to determine horizontal corneal diameter.","volume":"30","author":"Baumeister","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R11-11-20210210","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/S0886-3350(00)00830-0","article-title":"Predicting sulcus size using ocular measurements.","volume":"27","author":"Pop","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R12-11-20210210","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.jcrs.2007.10.010","article-title":"Corneal diameter measurements by corneal topography and angle-to-angle measurements by optical coherence tomography: evaluation of equivalence.","volume":"34","author":"Pinero","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R13-11-20210210","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1016\/j.jcrs.2007.11.034","article-title":"Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurements.","volume":"34","author":"Kim","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R14-11-20210210","doi-asserted-by":"crossref","first-page":"1713","DOI":"10.1016\/j.jcrs.2005.02.040","article-title":"Magnetic resonance imaging and Orbscan assessment of the anterior chamber.","volume":"31","author":"Fea","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R15-11-20210210","doi-asserted-by":"crossref","first-page":"454","DOI":"10.3928\/1081-597X-20040901-08","article-title":"Very high frequency ultrasound biometry of the anterior and posterior chamber diameter.","volume":"20","author":"Rondeau","year":"2004","journal-title":"J Refract Surg"},{"key":"R16-11-20210210","doi-asserted-by":"crossref","first-page":"185","DOI":"10.3928\/1081597X-20090201-03","article-title":"Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using Artemis VHF digital ultrasound.","volume":"25","author":"Reinstein","year":"2009","journal-title":"J Refract Surg"},{"key":"R17-11-20210210","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1016\/j.jcrs.2006.08.023","article-title":"Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurements.","volume":"32","author":"Kohnen","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R19-11-20210210","first-page":"35","article-title":"Anterior chamber phakic intraocular lenses.","volume":"3","author":"Baikoff","year":"2000","journal-title":"Operative Tech Cataract Refract Surg"},{"key":"R21-11-20210210","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1016\/S0886-3350(03)00065-8","article-title":"Implantable contact lens for moderate to high myopia; relationship of vaulting to cataract formation.","volume":"29","author":"Gonvers","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R22-11-20210210","doi-asserted-by":"crossref","first-page":"294","DOI":"10.3928\/1081-597X-19980501-13","article-title":"Posterior chamber phakic intraocular lens for myopia of 8 to 19 diopters.","volume":"14","author":"Zaldivar","year":"1998","journal-title":"J Refract Surg"},{"key":"R25-11-20210210","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1055\/s-2000-10583","article-title":"Besonderheiten der Kataraktchirurgie bei 79 Patienten mit relativem anterioren Mikrophthalmus (RAM): eine Ubersicht zur Anatomie, assoziierten Pathologie und Komplikationen Cataract surgery in 79 patients with relative anterior microphthalmos (RAM): a review on anatomy, associated pathology and complications.","volume":"216","author":"Auffarth","year":"2000","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"R27-11-20210210","doi-asserted-by":"crossref","first-page":"1625","DOI":"10.1001\/archopht.1989.01070020703032","article-title":"Simple microphthalmos.","volume":"107","author":"Weiss","year":"1989","journal-title":"Arch Ophthalmol"},{"key":"R29-11-20210210","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","article-title":"A three-part system for refining intraocular lens power calculations.","volume":"14","author":"Holladay","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"R30-11-20210210","doi-asserted-by":"crossref","first-page":"1722","DOI":"10.1016\/j.jcrs.2005.02.030","article-title":"Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer.","volume":"31","author":"Baikoff","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R33-11-20210210","first-page":"259","article-title":"White-to-white corneal diameter; normal values in healthy humans obtained with the Orbscan II topography system.","volume":"24","author":"Rufer","year":"2005","journal-title":"Cornea"},{"key":"R34-11-20210210","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/j.jcrs.2007.10.043","article-title":"Evaluation of the relationship between corneal diameter and lens diameter.","volume":"34","author":"Khng","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R36-11-20210210","doi-asserted-by":"crossref","first-page":"1961","DOI":"10.1016\/S0886-3350(01)01214-7","article-title":"Reproducibility of optical biometry using partial coherence interferometry; intraobserver and interobserver reliability.","volume":"27","author":"Vogel","year":"2001","journal-title":"J Cataract Refract Surg"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335010011946?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335010011946?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2010.05.017","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,12]],"date-time":"2021-11-12T19:10:29Z","timestamp":1636744229000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-201011000-00011"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11]]},"references-count":25,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2010]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2010.05.017","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2010,11]]}}}