{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T10:26:32Z","timestamp":1792146392184,"version":"4.4.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2012,10,1]],"date-time":"2012-10-01T00:00:00Z","timestamp":1349049600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2012,10]]},"DOI":"10.1016\/j.jcrs.2012.05.032","type":"journal-article","created":{"date-parts":[[2012,8,15]],"date-time":"2012-08-15T06:00:46Z","timestamp":1345010446000},"page":"1724-1733","source":"Crossref","is-referenced-by-count":58,"title":["Impact of corneal aberrations on through-focus image quality of presbyopia-correcting intraocular lenses using an adaptive optics bench system"],"prefix":"10.1097","volume":"38","author":[{"given":"Len","family":"Zheleznyak","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Myoung Joon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott","family":"MacRae","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geunyoung","family":"Yoon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-6-20210210","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.jcrs.2006.09.020","article-title":"Synchrony dual-optic accommodating intraocular lens. Part 1: optical and biomechanical principles and design considerations.","volume":"33","author":"McLeod","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R3-6-20210210","doi-asserted-by":"crossref","first-page":"2284","DOI":"10.1016\/j.jcrs.2003.07.010","article-title":"Understanding the accommodating intraocular lens.","volume":"29","author":"Rana","year":"2003","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"R4-6-20210210","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/BF02720789","article-title":"Ueber die Accomodation des Auges.","volume":"1","author":"Helmholtz","year":"1855","journal-title":"Albrecht von Graefes Arch Ophthalmol"},{"key":"R5-6-20210210","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1016\/S0886-3350(02)01652-8","article-title":"Intraocular lens movement caused by ciliary muscle contraction.","volume":"29","author":"Findl","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R7-6-20210210","first-page":"12","article-title":"Restoration of accommodation.","volume":"17","author":"Glasser","year":"2006","journal-title":"Curr Opin Ophthalmol"},{"key":"R8-6-20210210","doi-asserted-by":"crossref","first-page":"218","DOI":"10.3928\/1081597X-20080301-02","article-title":"Optical performance measurement and night driving simulation of ReSTOR, ReZoom, and Tecnis multifocal intraocular lenses in a model eye.","volume":"24","author":"Choi","year":"2008","journal-title":"J Refract Surg"},{"key":"R9-6-20210210","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1016\/j.jcrs.2006.02.006","article-title":"History and development of the apodized diffractive intraocular lens.","volume":"32","author":"Davison","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R10-6-20210210","doi-asserted-by":"crossref","first-page":"1841","DOI":"10.1364\/JOSAA.20.001841","article-title":"Optical aberrations of intraocular lenses measured in vivo and in vitro.","volume":"20","author":"Barbero","year":"2003","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"R11-6-20210210","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1016\/j.jcrs.2011.03.033","article-title":"Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system.","volume":"37","author":"Kim","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R13-6-20210210","doi-asserted-by":"crossref","first-page":"6595","DOI":"10.1364\/AO.46.006595","article-title":"Model eyes for evaluation of intraocular lenses.","volume":"46","author":"Norrby","year":"2007","journal-title":"Appl Opt"},{"key":"R14-6-20210210","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/S0002-9394(00)00526-2","article-title":"Influence of astigmatism on multifocal and monofocal intraocular lenses.","volume":"130","author":"Hayashi","year":"2000","journal-title":"Am J Ophthalmol"},{"key":"R15-6-20210210","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/j.jcrs.2010.02.016","article-title":"Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens.","volume":"36","author":"Hayashi","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R16-6-20210210","doi-asserted-by":"crossref","first-page":"1793","DOI":"10.1364\/JOSAA.18.001793","article-title":"Monochromatic aberrations of the human eye in a large population.","volume":"18","author":"Porter","year":"2001","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"R17-6-20210210","doi-asserted-by":"crossref","first-page":"1697","DOI":"10.1364\/JOSAA.17.001697","article-title":"Optical aberrations of the human cornea as a function of age.","volume":"17","author":"Guirao","year":"2000","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"R18-6-20210210","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1016\/j.ajo.2004.01.005","article-title":"Age-related changes in corneal and ocular higher-order wavefront aberrations.","volume":"137","author":"Amano","year":"2004","journal-title":"Am J Ophthalmol"},{"key":"R21-6-20210210","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1016\/j.jcrs.2009.01.034","article-title":"Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye.","volume":"35","author":"Eppig","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R22-6-20210210","doi-asserted-by":"crossref","first-page":"223","DOI":"10.3928\/1081597X-20080301-03","article-title":"Visualization of the retinal image in an eye model with spherical and aspheric, diffractive, and refractive multifocal intraocular lenses.","volume":"24","author":"Terwee","year":"2008","journal-title":"J Refract Surg"},{"key":"R23-6-20210210","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1016\/j.jcrs.2006.01.026","article-title":"Optomechanical eye model with imaging capabilities for objective evaluation of intraocular lenses.","volume":"32","author":"Gobbi","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R24-6-20210210","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.jcrs.2008.10.026","article-title":"Performance of presbyopia-correcting intraocular lenses in distance optical bench tests.","volume":"35","author":"Maxwell","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R26-6-20210210","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.jcrs.2010.08.043","article-title":"Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens.","volume":"37","author":"Alio","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R28-6-20210210","doi-asserted-by":"crossref","first-page":"683","DOI":"10.3928\/1081-597X-20021101-04","article-title":"A new intraocular lens design to reduce spherical aberration of pseudophakic eyes.","volume":"18","author":"Holladay","year":"2002","journal-title":"J Refract Surg"},{"key":"R29-6-20210210","doi-asserted-by":"crossref","first-page":"947","DOI":"10.3928\/1081-597X-20071101-16","article-title":"Correcting highly aberrated eyes using large-stroke adaptive optics.","volume":"23","author":"Sabesan","year":"2007","journal-title":"J Refract Surg"},{"key":"R31-6-20210210","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1016\/S0042-6989(98)00317-4","article-title":"The depth-of-field of the human eye from objective and subjective measurements.","volume":"39","author":"Marcos","year":"1999","journal-title":"Vision Res"},{"key":"R32-6-20210210","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1364\/JOSAA.4.000851","article-title":"Tolerance to visual defocus.","volume":"4","author":"Legge","year":"1987","journal-title":"J Opt Soc Am A"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335012008899?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335012008899?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2012.05.032","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,26]],"date-time":"2022-01-26T16:06:32Z","timestamp":1643213192000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-201210000-00006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,10]]},"references-count":24,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2012]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2012.05.032","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2012,10]]}}}