{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T19:13:16Z","timestamp":1771355596001,"version":"3.50.1"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2012,10,1]],"date-time":"2012-10-01T00:00:00Z","timestamp":1349049600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2012,10]]},"DOI":"10.1016\/j.jcrs.2012.06.047","type":"journal-article","created":{"date-parts":[[2012,8,22]],"date-time":"2012-08-22T18:47:19Z","timestamp":1345661239000},"page":"1808-1816","source":"Crossref","is-referenced-by-count":38,"title":["Reading performance and patient satisfaction after corneal inlay implantation for presbyopia correction: Two-year follow-up"],"prefix":"10.1097","volume":"38","author":[{"given":"Alois K.","family":"Dexl","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Orang","family":"Seyeddain","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolfgang","family":"Riha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Theresa","family":"R\u00fcckl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Bachernegg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Emesz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Josef","family":"Ruckhofer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G\u00fcnther","family":"Grabner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-18-20210210","first-page":"10","article-title":"Queratoplastia refractiva. Estudios e informaciones.","volume":"2","author":"Barraquer","year":"1949","journal-title":"Oftalmologicas (Barcelona)"},{"key":"R4-18-20210210","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/S0161-6420(88)33169-6","article-title":"Histopathology and clinical behavior of polysulfone intracorneal implants in the baboon model; polysulfone lens implants.","volume":"95","author":"Deg","year":"1988","journal-title":"Ophthalmology"},{"key":"R5-18-20210210","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/S0886-3350(86)80057-8","article-title":"Polysulfone corneal lenses.","volume":"12","author":"Lane","year":"1986","journal-title":"J Cataract Refract Surg"},{"key":"R6-18-20210210","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1016\/j.ophtha.2009.05.019","article-title":"Hydrogel intracorneal inlays for the correction of hyperopia; outcomes and complications after 5 years of follow-up.","volume":"116","author":"Mulet","year":"2009","journal-title":"Ophthalmology"},{"key":"R8-18-20210210","doi-asserted-by":"crossref","first-page":"1525","DOI":"10.1002\/jbm.820291209","article-title":"Polyvinylidene fluoride (PVDF) as a biomaterial: from polymeric raw material to monofilament vascular suture.","volume":"29","author":"Laroche","year":"1995","journal-title":"J Biomed Mater Res"},{"key":"R10-18-20210210","doi-asserted-by":"crossref","first-page":"1921","DOI":"10.1016\/j.jcrs.2008.07.015","article-title":"F, Bayraktar S, Agca A, Yilmaz B, McDonald MB, van de Pol C. Intracorneal inlay for the surgical correction of presbyopia.","volume":"34","author":"Yilmaz","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R12-18-20210210","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/j.jcrs.2010.10.044","article-title":"Reading performance after implantation of a small-aperture corneal inlay for the surgical correction of presbyopia: two-year follow-up.","volume":"37","author":"Dexl","year":"2011","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"R13-18-20210210","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1097\/IIO.0b013e31820f2071","article-title":"Corneal inlays for the treatment of presbyopia.","volume":"51","author":"Waring","year":"2011","journal-title":"Int Ophthalmol Clin"},{"key":"R14-18-20210210","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1016\/j.ajo.2011.08.044","article-title":"Reading performance after implantation of a modified corneal inlay design for the surgical correction of presbyopia: 1-year follow-up.","volume":"153","author":"Dexl","year":"2012","journal-title":"Am J Ophthalmol"},{"key":"R15-18-20210210","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.jcrs.2011.08.031","article-title":"One-year visual outcomes and patient satisfaction after surgical correction of presbyopia with an intracorneal inlay of a new design.","volume":"38","author":"Dexl","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R16-18-20210210","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1016\/j.jcrs.2011.01.027","article-title":"F, Alagoz N, Pekel G, Azman E, Aksoy EF, Cakir H, Bozkurt E, Demirok A. Intracorneal inlay to correct presbyopia: long-term results.","volume":"37","author":"Yilmaz","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R17-18-20210210","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.jcrs.2011.07.027","article-title":"Small-aperture corneal inlay for the correction of presbyopia: 3-year follow-up.","volume":"38","author":"Seyeddain","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R18-18-20210210","doi-asserted-by":"crossref","first-page":"818","DOI":"10.3928\/1081597X-20110706-01","article-title":"Femtosecond laser-assisted corneal pocket creation using a mask for inlay implantation.","volume":"27","author":"Bouzoukis","year":"2011","journal-title":"J Refract Surg"},{"key":"R19-18-20210210","doi-asserted-by":"crossref","first-page":"682","DOI":"10.3928\/1081597X-20091119-01","article-title":"Device for improving quantification of reading acuity and reading speed.","volume":"26","author":"Dexl","year":"2010","journal-title":"J Refract Surg"},{"key":"R21-18-20210210","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1016\/j.jcrs.2010.11.039","article-title":"Postoperative bilateral reading performance with 4 intraocular lens models: six-month results.","volume":"37","author":"Alio","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R22-18-20210210","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1055\/s-0031-1281619","article-title":"Einsatz des Salzburg Reading Desk fur die Presbyopie- und Akkommodationsforschung Application of the Salzburg Reading Desk in accommodation and presbyopic research.","volume":"228","author":"Dexl","year":"2011","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"R24-18-20210210","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1007\/s00417-002-0443-5","article-title":"The validity and reliability of short German sentences for measuring reading speed.","volume":"240","author":"Radner","year":"2002","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R25-18-20210210","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s00417-003-0776-8","article-title":"Reliability of a standardized reading chart system: variance component analysis, test retest and inter-chart reliability.","volume":"242","author":"Stifter","year":"2004","journal-title":"Graefes Arch Clin Exp Ophthalmol"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335012009741?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335012009741?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2012.06.047","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,13]],"date-time":"2021-05-13T17:04:28Z","timestamp":1620925468000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-201210000-00018"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,10]]},"references-count":18,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2012]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2012.06.047","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2012,10]]}}}