{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T09:25:52Z","timestamp":1792661152714,"version":"4.5.0"},"reference-count":78,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","license":[{"start":{"date-parts":[[2012,12,1]],"date-time":"2012-12-01T00:00:00Z","timestamp":1354320000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2012,12]]},"DOI":"10.1016\/j.jcrs.2012.10.022","type":"journal-article","created":{"date-parts":[[2012,11,27]],"date-time":"2012-11-27T20:23:29Z","timestamp":1354047809000},"page":"2167-2183","source":"Crossref","is-referenced-by-count":141,"title":["Characterization of corneal structure in keratoconus"],"prefix":"10.1097","volume":"38","author":[{"given":"David P.","family":"Pi\u00f1ero","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan C.","family":"Nieto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Lopez-Miguel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R4-17-20210210","doi-asserted-by":"crossref","first-page":"539","DOI":"10.3928\/1081-597X-20060601-05","article-title":"Corneal higher order aberrations: a method to grade keratoconus.","volume":"22","author":"Alio","year":"2006","journal-title":"J Refract Surg"},{"key":"R5-17-20210210","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.clae.2004.12.001","article-title":"Corneal wavefront aberration measurements to detect keratoconus patients.","volume":"28","author":"Gobbe","year":"2005","journal-title":"Contact Lens Anterior Eye"},{"key":"R6-17-20210210","doi-asserted-by":"crossref","first-page":"263","DOI":"10.3928\/1081-597X-20020501-09","article-title":"Validation of the estimation of corneal aberrations from videokeratography in keratoconus.","volume":"18","author":"Barbero","year":"2002","journal-title":"J Refract Surg"},{"key":"R8-17-20210210","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/S1532-0464(02)00513-0","article-title":"Neural network-based system for early keratoconus detection from corneal topography.","volume":"35","author":"Accardo","year":"2002","journal-title":"J Biomed Inform"},{"key":"R9-17-20210210","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/S0886-3350(97)80344-6","article-title":"Corneal topography using the Holladay Diagnostic Summary.","volume":"23","author":"Holladay","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R10-17-20210210","doi-asserted-by":"crossref","first-page":"595","DOI":"10.3928\/1081-597X-19960701-11","article-title":"Measurement of irregular astigmatism using semimeridian data from videokeratographs.","volume":"12","author":"Borderie","year":"1996","journal-title":"J Refract Surg"},{"key":"R11-17-20210210","first-page":"164","article-title":"Automated topographic screening for keratoconus in refractive surgery candidates.","volume":"22","author":"Kalin","year":"1996","journal-title":"CLAO J"},{"key":"R12-17-20210210","doi-asserted-by":"crossref","first-page":"400","DOI":"10.3928\/1081-597X-19891101-10","article-title":"Computer-assisted corneal topography in keratoconus.","volume":"5","author":"Rabinowitz","year":"1989","journal-title":"Refract Corneal Surg"},{"key":"R13-17-20210210","doi-asserted-by":"crossref","first-page":"372","DOI":"10.3928\/1081-597X-19891101-06","article-title":"Quantitative descriptors of corneal shape derived from computer-assisted analysis of photokeratographs.","volume":"5","author":"Dingeldein","year":"1989","journal-title":"Refract Corneal Surg"},{"key":"R14-17-20210210","doi-asserted-by":"crossref","first-page":"1534","DOI":"10.1016\/j.ophtha.2008.02.020","article-title":"Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconussubclinical keratoconus.","volume":"115","author":"De Sanctis","year":"2008","journal-title":"Ophthalmology"},{"key":"R15-17-20210210","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1016\/j.jcrs.2007.11.054","article-title":"Comparative evaluation of refractive surgery candidates with Placido topography, Orbscan II, Pentacam, and wavefront analysis.","volume":"34","author":"Nilforoushan","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R16-17-20210210","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.jcrs.2007.12.036","article-title":"Comparison of and correlation between anterior and posterior corneal elevation maps in normal eyes and keratoconus-suspect eyes.","volume":"34","author":"Schlegel","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R17-17-20210210","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.ajo.2006.11.062","article-title":"Defining subclinical keratoconus using corneal first-surface higher-order aberrations.","volume":"143","author":"Buhren","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"R18-17-20210210","doi-asserted-by":"crossref","first-page":"774","DOI":"10.3928\/1081-597X-20071001-06","article-title":"Higher order aberrations and topography in early and suspected keratoconus.","volume":"23","author":"Jafri","year":"2007","journal-title":"J Refract Surg"},{"key":"R19-17-20210210","doi-asserted-by":"crossref","first-page":"825","DOI":"10.3928\/1081-597X-20071001-13","article-title":"Evaluation of higher order ocular aberrations in patients with keratoconus.","volume":"23","author":"Lim","year":"2007","journal-title":"J Refract Surg"},{"key":"R20-17-20210210","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1016\/S0161-6420(00)00159-7","article-title":"Changes in anterior and posterior corneal curvatures in keratoconus.","volume":"107","author":"Tomidokoro","year":"2000","journal-title":"Ophthalmology"},{"key":"R21-17-20210210","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1016\/j.ajo.2006.11.044","article-title":"Identification of scanning slit-beam topographic parameters important in distinguishing normal from keratoconic corneal morphologic features.","volume":"143","author":"Sonmez","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"R22-17-20210210","doi-asserted-by":"crossref","first-page":"1642","DOI":"10.1016\/S0161-6420(02)01121-1","article-title":"Role of Orbscan II in screening keratoconus suspects before refractive corneal surgery.","volume":"109","author":"Rao","year":"2002","journal-title":"Ophthalmology"},{"key":"R24-17-20210210","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1016\/j.jcrs.2006.06.025","article-title":"Corneal-thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus.","volume":"32","author":"Ambrosio","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R25-17-20210210","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1097\/00003226-200301000-00002","article-title":"Study of corneal topographic patterns with single continuous suturing techniques in penetrating keratoplasty.","volume":"22","author":"Sharma","year":"2003","journal-title":"Cornea"},{"key":"R27-17-20210210","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1016\/S0886-3350(97)80242-8","article-title":"Characteristics of normal corneal topography using the EyeSys corneal analysis system.","volume":"23","author":"Alvi","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R28-17-20210210","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/S0886-3350(97)80345-8","article-title":"Rasterstereography-based classification of normal corneas.","volume":"23","author":"Naufal","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R30-17-20210210","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1097\/00003226-199101000-00002","article-title":"Corneal topography of keratoconus.","volume":"10","author":"Wilson","year":"1991","journal-title":"Cornea"},{"key":"R31-17-20210210","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/S0886-3350(99)00355-7","article-title":"Keratoconus evaluation using the Orbscan Topography System.","volume":"26","author":"Auffarth","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R32-17-20210210","doi-asserted-by":"crossref","first-page":"1184","DOI":"10.1016\/S0886-3350(98)80009-6","article-title":"Axial, instantaneous, and refractive formulas in computerized videokeratography of normal corneas.","volume":"24","author":"Bafna","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R33-17-20210210","first-page":"22","article-title":"Comparison of axial and instantaneous videokeratographic data in keratoconus and utility in contact lens curvature prediction.","volume":"24","author":"Szczotka","year":"1998","journal-title":"CLAO J"},{"key":"R34-17-20210210","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1016\/S0002-9394(14)70388-5","article-title":"Tangential vs sagittal videokeratographs in the early detection of keratoconus.","volume":"122","author":"Rabinowitz","year":"1996","journal-title":"Am J Ophthalmol"},{"key":"R35-17-20210210","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1097\/00003226-199505000-00006","article-title":"Analysis of the inherent error of the TMS-1 Topographic Modeling System in mapping a radially aspheric surface.","volume":"14","author":"Roberts","year":"1995","journal-title":"Cornea"},{"key":"R36-17-20210210","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1097\/00006324-199511000-00004","article-title":"Accuracy of videokeratography for instantaneous radius in keratoconus.","volume":"72","author":"Chan","year":"1995","journal-title":"Optom Vis Sci"},{"key":"R38-17-20210210","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/S0161-6420(01)00888-0","article-title":"The Universal Standard Scale; proposed improvements to the American National Standards Institute (ANSI) scale for corneal topography.","volume":"109","author":"Smolek","year":"2002","journal-title":"Ophthalmology"},{"key":"R40-17-20210210","doi-asserted-by":"crossref","first-page":"1723","DOI":"10.1016\/S0161-6420(93)31410-7","article-title":"Standarized color-coded maps for corneal topography.","volume":"100","author":"Wilson","year":"1993","journal-title":"Ophthalmology"},{"key":"R41-17-20210210","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1016\/j.jcrs.2006.11.004","article-title":"Asphericity of the anterior human cornea with different corneal diameters.","volume":"33","author":"Gonzalez-Meijome","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R43-17-20210210","first-page":"107","article-title":"Mean topography of the normal corneas.","volume":"57","author":"Clark","year":"1974","journal-title":"Aust J Optom"},{"key":"R44-17-20210210","first-page":"183","article-title":"Mathematical model of the corneal contour.","volume":"26","author":"Mandell","year":"1971","journal-title":"Br J Physiol Opt"},{"key":"R46-17-20210210","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1016\/j.jcrs.2009.11.012","article-title":"Corneal volume, pachymetry, and correlation of anterior and posterior corneal shape in subclinical and different stages of clinical keratoconus.","volume":"36","author":"Pinero","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R49-17-20210210","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1016\/j.ophtha.2006.10.022","article-title":"Vertical D; a novel topographic pattern in some keratoconus suspects.","volume":"114","author":"Abad","year":"2007","journal-title":"Ophthalmology"},{"key":"R50-17-20210210","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/S0161-6420(99)00084-6","article-title":"Comparison of topographic indices that correlate with visual acuity in videokeratography.","volume":"107","author":"Shiotani","year":"2000","journal-title":"Ophthalmology"},{"key":"R51-17-20210210","doi-asserted-by":"crossref","first-page":"371","DOI":"10.3928\/1081-597X-19950901-14","article-title":"Videokeratographic indices to aid in screening for keratoconus.","volume":"11","author":"Rabinowitz","year":"1995","journal-title":"J Refract Surg"},{"key":"R53-17-20210210","first-page":"480","article-title":"KISA index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus. J Cataract Refract Surg. 1999;25:1327-1335.","volume":"26","author":"Rabinowitz","year":"2000","journal-title":"errata"},{"key":"R54-17-20210210","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/00055735-199508000-00010","article-title":"Corneal topography.","volume":"6","author":"Rabinowitz","year":"1995","journal-title":"Curr Opin Ophthalmol"},{"key":"R56-17-20210210","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1001\/archopht.1995.01100070044023","article-title":"Comparison of methods for detecting keratoconus using videokeratography.","volume":"113","author":"Maeda","year":"1995","journal-title":"Arch Ophthalmol"},{"key":"R58-17-20210210","first-page":"75","article-title":"The use of Pentacam for keratoconus diagnosis and progress evaluation. Polish.","volume":"113","author":"Kopacz","year":"2011","journal-title":"Klin Oczna"},{"key":"R60-17-20210210","doi-asserted-by":"crossref","first-page":"582","DOI":"10.3928\/1081597X-20080601-06","article-title":"Comparison of Zernike and Fourier wavefront reconstruction algorithms in representing corneal aberration of normal and abnormal eyes.","volume":"24","author":"Yoon","year":"2008","journal-title":"J Refract Surg"},{"key":"R62-17-20210210","doi-asserted-by":"crossref","first-page":"2350","DOI":"10.1016\/j.jcrs.2005.05.025","article-title":"Goodness-of-prediction of Zernike polynomials fitting to corneal surfaces.","volume":"31","author":"Smolek","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R64-17-20210210","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1097\/OPX.0b013e3182279ff8","article-title":"Placido-based indices of corneal irregularity.","volume":"88","author":"Ramos-Lopez","year":"2011","journal-title":"Optom Vis Sci"},{"key":"R65-17-20210210","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1016\/j.jcrs.2006.02.060","article-title":"Corneal elevation indices in normal and keratoconic eyes.","volume":"32","author":"Fam","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R67-17-20210210","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1016\/j.jcrs.2010.10.046","article-title":"Keratoconus-integrated characterization considering anterior corneal aberrations, internal astigmatism, and corneal biomechanics.","volume":"37","author":"Alio","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R68-17-20210210","doi-asserted-by":"crossref","first-page":"507","DOI":"10.3928\/1081-597X-20000901-04","article-title":"Corneal first surface optical aberrations and visual performance.","volume":"16","author":"Applegate","year":"2000","journal-title":"J Refract Surg"},{"key":"R72-17-20210210","doi-asserted-by":"crossref","first-page":"1114","DOI":"10.1016\/j.jcrs.2004.11.051","article-title":"Clinical comparison of 6 aberrometers. Part 1: technical specifications.","volume":"31","author":"Rozema","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R73-17-20210210","doi-asserted-by":"crossref","first-page":"24","DOI":"10.3928\/1081-597X-20030101-05","article-title":"Corneal topographic and pachymetric screening of keratorefractive patients.","volume":"19","author":"Ambrosio","year":"2003","journal-title":"J Refract Surg"},{"key":"R74-17-20210210","doi-asserted-by":"crossref","first-page":"1708","DOI":"10.1016\/j.jcrs.2007.06.020","article-title":"Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam system.","volume":"33","author":"Emre","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R76-17-20210210","doi-asserted-by":"crossref","first-page":"753","DOI":"10.3928\/1081597X-20110721-01","article-title":"Novel pachymetric parameters based on corneal tomography for diagnosing keratoconus.","volume":"27","author":"Ambrosio","year":"2011","journal-title":"J Refract Surg"},{"key":"R77-17-20210210","doi-asserted-by":"crossref","first-page":"2159","DOI":"10.1016\/j.ophtha.2008.08.004","article-title":"Keratoconus diagnosis with optical coherence tomography pachymetry mapping.","volume":"115","author":"Li","year":"2008","journal-title":"Ophthalmology"},{"key":"R78-17-20210210","doi-asserted-by":"crossref","first-page":"604","DOI":"10.3928\/1081597X-20090610-06","article-title":"Corneal epithelial thickness profile in the diagnosis of keratoconus.","volume":"25","author":"Reinstein","year":"2009","journal-title":"J Refract Surg"},{"key":"R80-17-20210210","doi-asserted-by":"crossref","first-page":"522","DOI":"10.3109\/02713683.2011.553306","article-title":"Reduction in corneal volume with severity of keratoconus.","volume":"36","author":"Mannion","year":"2011","journal-title":"Curr Eye Res"},{"key":"R81-17-20210210","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1111\/j.1475-1313.2009.00642.x","article-title":"Determination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyes.","volume":"29","author":"Cervino","year":"2009","journal-title":"Ophthalmic Physiol Opt"},{"key":"R83-17-20210210","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.1016\/j.jcrs.2007.04.021","article-title":"Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes.","volume":"33","author":"Ortiz","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R84-17-20210210","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jcrs.2004.10.044","article-title":"Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.","volume":"31","author":"Luce","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R86-17-20210210","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1016\/j.ophtha.2009.09.023","article-title":"Corneal biomechanical metrics and anterior segment parameters in mild keratoconus.","volume":"117","author":"Fontes","year":"2010","journal-title":"Ophthalmology"},{"key":"R87-17-20210210","doi-asserted-by":"crossref","first-page":"202","DOI":"10.3928\/1081597X-20120103-03","article-title":"Improved keratoconus detection by ocular response analyzer testing after consideration of corneal thickness as a confounding factor.","volume":"28","author":"Galletti","year":"2012","journal-title":"J Refract Surg"},{"key":"R88-17-20210210","doi-asserted-by":"crossref","first-page":"2144","DOI":"10.1016\/j.jcrs.2011.06.029","article-title":"Early biomechanical keratoconus pattern measured with an ocular response analyzer: curve analysis.","volume":"37","author":"Touboul","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R89-17-20210210","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1016\/j.ophtha.2003.12.024","article-title":"Videokeratographic anomalies in familial keratoconus.","volume":"111","author":"Levy","year":"2004","journal-title":"Ophthalmology"},{"key":"R90-17-20210210","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/S0161-6420(93)31673-8","article-title":"Videokeratography of the fellow eye in unilateral keratoconus.","volume":"100","author":"Rabinowitz","year":"1993","journal-title":"Ophthalmology"},{"key":"R91-17-20210210","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1001\/archopht.1990.01070050063032","article-title":"Computer-assisted corneal topography in family members of keratoconus.","volume":"108","author":"Rabinowitz","year":"1990","journal-title":"Arch Ophthalmol"},{"key":"R92-17-20210210","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.jcrs.2010.12.049","article-title":"O, Cetinkor V, Ozkan M, Kanpolat A. Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes.","volume":"37","author":"Ucakhan","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R93-17-20210210","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1016\/j.jcrs.2009.12.046","article-title":"Anterior chamber characteristics of keratoconus assessed by rotating Scheimpflug imaging.","volume":"36","author":"Kovacs","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R94-17-20210210","doi-asserted-by":"crossref","first-page":"2198","DOI":"10.1016\/j.ophtha.2006.06.032","article-title":"Topography-guided surface ablation for Forme Frustre Keratoconus.","volume":"113","author":"Koller","year":"2006","journal-title":"Ophthalmology"},{"key":"R95-17-20210210","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/S0161-6420(02)01727-X","article-title":"Risk factors and prognosis for corneal ectasia after LASIK.","volume":"110","author":"Randleman","year":"2003","journal-title":"Ophthalmology"},{"key":"R96-17-20210210","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1016\/j.ophtha.2005.11.023","article-title":"Corneal ectasia after photorefractive keratectomy for low myopia.","volume":"113","author":"Malecaze","year":"2006","journal-title":"Ophthalmology"},{"key":"R97-17-20210210","doi-asserted-by":"crossref","first-page":"438","DOI":"10.3928\/1081-597X-20000701-06","article-title":"Results of photorefractive keratectomy in keratoconus suspects at 4 years.","volume":"16","author":"Bilgihan","year":"2000","journal-title":"J Refract Surg"},{"key":"R98-17-20210210","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.clae.2005.10.002","article-title":"Atypical unilateral superior keratoconus in young males.","volume":"28","author":"Weed","year":"2005","journal-title":"Cont Lens Anterior Eye"},{"key":"R99-17-20210210","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1097\/00003226-199711000-00016","article-title":"Superior keratoconus.","volume":"16","author":"Prisant","year":"1997","journal-title":"Cornea"},{"key":"R100-17-20210210","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.jcrs.2004.06.087","article-title":"Surface and Orbscan II slit-scanning elevation topography in circumscribed posterior keratoconus.","volume":"31","author":"Charles","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R101-17-20210210","first-page":"551","article-title":"Keratoconus posticus.","volume":"50","author":"Butler","year":"1930","journal-title":"Trans Ophthalmol Soc U K"},{"key":"R102-17-20210210","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1097\/00003226-199207000-00014","article-title":"Corneal topography of posterior keratoconus.","volume":"11","author":"Mannis","year":"1992","journal-title":"Cornea"},{"key":"R103-17-20210210","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1097\/01.icl.0000189193.28870.81","article-title":"Factors influencing lid pressure on the cornea.","volume":"32","author":"Collins","year":"2006","journal-title":"Eye Contact Lens"},{"key":"R104-17-20210210","first-page":"114","article-title":"Differentiating contact lens induced warpage from true keratoconus using corneal topography.","volume":"25","author":"Lebow","year":"1999","journal-title":"CLAO J"},{"key":"R105-17-20210210","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/00003226-200301000-00006","article-title":"Keratoconus-like topographic changes in keratoconjunctivitis sicca.","volume":"22","author":"de Paiva","year":"2003","journal-title":"Cornea"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335012014782?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335012014782?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2012.10.022","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T12:29:07Z","timestamp":1643718547000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-201212000-00017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,12]]},"references-count":78,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2012]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2012.10.022","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2012,12]]}}}