{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T20:14:03Z","timestamp":1793045643895,"version":"4.5.0"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","license":[{"start":{"date-parts":[[2014,7,1]],"date-time":"2014-07-01T00:00:00Z","timestamp":1404172800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["jcrsjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2014,7]]},"DOI":"10.1016\/j.jcrs.2013.11.034","type":"journal-article","created":{"date-parts":[[2014,6,20]],"date-time":"2014-06-20T17:21:10Z","timestamp":1403284870000},"page":"1155-1162","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":25,"title":["Collagen copolymer toric phakic intraocular lens for myopic astigmatism: One-year follow-up"],"prefix":"10.1097","volume":"40","author":[{"given":"Jos\u00e9 F.","family":"Alfonso","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos","family":"Lisa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bel\u00e9n","family":"Alfonso-Bartolozzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cari","family":"P\u00e9rez-Vives","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Mont\u00e9s-Mic\u00f3","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-16-20210210","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.jcrs.2012.09.024","article-title":"Efficacy and predictability of laser in situ keratomileusis for low astigmatism of 0.75 diopter or less.","volume":"39","author":"Frings","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R2-16-20210210","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.jcrs.2012.08.054","article-title":"Laser in situ keratomileusis for high astigmatism in myopic and hyperopic eyes.","volume":"39","author":"Ivarsen","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R3-16-20210210","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/S0161-6420(02)01447-1","article-title":"Toric phakic intraocular lens; European multicenter study.","volume":"110","author":"Dick","year":"2003","journal-title":"Ophthalmology"},{"key":"R4-16-20210210","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1016\/j.jcrs.2006.02.058","article-title":"Iris-fixated toric phakic intraocular lens: three-year follow-up.","volume":"32","author":"Tehrani","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R5-16-20210210","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1016\/j.ophtha.2007.08.022","article-title":"Five-year follow-up of 399 phakic Artisan-Verisyse implantation for myopia, hyperopia, andor astigmatism.","volume":"115","author":"Guell","year":"2008","journal-title":"Ophthalmology"},{"key":"R7-16-20210210","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1016\/j.ophtha.2004.03.026","article-title":"United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopia; three-year follow-up.","volume":"111","year":"2004","journal-title":"Ophthalmology"},{"key":"R8-16-20210210","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.ophtha.2006.08.049","article-title":"Toric Implantable Oollamer Lens for moderate to high myopic astigmatism.","volume":"114","author":"Sanders","year":"2007","journal-title":"Ophthalmology"},{"key":"R9-16-20210210","doi-asserted-by":"crossref","first-page":"S939","DOI":"10.3928\/1081597X-20090915-08","article-title":"Axis alignment and rotational stability after implantation of the toric implantable collamer lens for myopic astigmatism.","volume":"25","author":"Hashem","year":"2009","journal-title":"J Refract Surg"},{"key":"R10-16-20210210","doi-asserted-by":"crossref","first-page":"403","DOI":"10.3928\/1081597X-20090422-01","article-title":"Postoperative astigmatism and axis stability after implantation of the STAAR Toric Implantable Collamer Lens.","volume":"25","author":"Park","year":"2009","journal-title":"J Refract Surg"},{"key":"R11-16-20210210","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1111\/j.1442-9071.2010.02273.x","article-title":"Toric implantable collamer lens for patients with moderate to severe myopic astigmatism: 12-month follow-up.","volume":"38","author":"Bhikoo","year":"2010","journal-title":"Clin Exp Ophthalmol"},{"key":"R12-16-20210210","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1016\/j.jcrs.2009.10.052","article-title":"Collagen copolymer toric posterior chamber phakic intraocular lens for myopic astigmatism; one-year follow-up.","volume":"36","author":"Alfonso","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R13-16-20210210","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1016\/j.jcrs.2010.02.022","article-title":"Collagen copolymer toric posterior chamber phakic intraocular lenses to correct high myopic astigmatism.","volume":"36","author":"Alfonso","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R14-16-20210210","doi-asserted-by":"crossref","first-page":"2287","DOI":"10.1016\/j.ophtha.2010.03.054","article-title":"One-year follow-up of posterior chamber toric phakic intraocular lens implantation for moderate to high myopic astigmatism.","volume":"117","author":"Kamiya","year":"2010","journal-title":"Ophthalmology"},{"key":"R15-16-20210210","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1097\/ICO.0b013e31802cbf3c","article-title":"Comparison of implantable collamer lens (ICL) and laser-assisted in situ keratomileusis (LASIK) for low myopia.","volume":"25","author":"Sanders","year":"2006","journal-title":"Cornea"},{"key":"R16-16-20210210","doi-asserted-by":"crossref","first-page":"106","DOI":"10.3928\/1081597X-20111018-02","article-title":"Kim T-i. Comparison of higher order aberrations after Implantable Collamer Lens implantation and wavefront-guided LASEK in high myopia.","volume":"28","author":"Shin","year":"2012","journal-title":"J Refract Surg"},{"key":"R17-16-20210210","doi-asserted-by":"crossref","first-page":"39","DOI":"10.5301\/ejo.5000188","article-title":"Optical and visual quality comparison of implantable Collamer lens and laser in situ keratomileusis for myopia using an adaptive optics visual simulator.","volume":"23","author":"Perez-Vives","year":"2013","journal-title":"Eur J Ophthalmol"},{"key":"R18-16-20210210","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/S0886-3350(00)00797-5","article-title":"Power vector analysis of the optical outcome of refractive surgery.","volume":"27","author":"Thibos","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R19-16-20210210","doi-asserted-by":"crossref","first-page":"765","DOI":"10.3928\/1081597X-20110617-01","article-title":"Implantable Collamer posterior chamber intraocular lenses: a review of potential complications.","volume":"27","author":"Fernandes","year":"2011","journal-title":"J Refract Surg"},{"key":"R20-16-20210210","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1016\/j.jcrs.2003.09.047","article-title":"ICL in Treatment of Myopia Study Group. Corneal endothelial assessment after ICL implantation.","volume":"30","author":"Edelhauser","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R21-16-20210210","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1016\/j.jcrs.2003.09.019","article-title":"Pupillary block glaucoma secondary to posterior chamber phakic intraocular lens implantation for high myopia.","volume":"30","author":"Smallman","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R22-16-20210210","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0002-9394(02)01414-9","article-title":"Refractory intraocular pressure increase after phakic posterior chamber intraocular lens implantation.","volume":"134","author":"Sanchez-Galeana","year":"2002","journal-title":"Am J Ophthalmol"},{"key":"R23-16-20210210","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/S0161-6420(02)01973-5","article-title":"Lens opacities after posterior chamber phakic intraocular lens implantation.","volume":"110","author":"Sanchez-Galeana","year":"2003","journal-title":"Ophthalmology"},{"key":"R24-16-20210210","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1016\/j.jcrs.2010.11.040","article-title":"Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: five-year follow-up.","volume":"37","author":"Alfonso","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R25-16-20210210","doi-asserted-by":"crossref","first-page":"1827","DOI":"10.1007\/s00417-010-1322-0","article-title":"Three-year follow-up of subjective vault following myopic implantable collamer lens implantation.","volume":"248","author":"Alfonso","year":"2010","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R26-16-20210210","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.jcrs.2011.07.035","article-title":"Central vault after phakic intraocular lens implantation: correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age.","volume":"38","author":"Alfonso","year":"2012","journal-title":"J Cataract Refract Surg"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335014005215?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335014005215?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2013.11.034","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,15]],"date-time":"2021-06-15T18:16:22Z","timestamp":1623780982000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-201407000-00016"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,7]]},"references-count":25,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2014]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2013.11.034","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2014,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Collagen copolymer toric phakic intraocular lens for myopic astigmatism: One-year follow-up","name":"articletitle","label":"Article Title"},{"value":"Journal of Cataract & Refractive Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcrs.2013.11.034","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}