{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T16:21:33Z","timestamp":1778170893971,"version":"3.51.4"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2014,6,1]],"date-time":"2014-06-01T00:00:00Z","timestamp":1401580800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014,6]]},"DOI":"10.1016\/j.jcrs.2014.02.032","type":"journal-article","created":{"date-parts":[[2014,5,22]],"date-time":"2014-05-22T04:29:15Z","timestamp":1400732955000},"page":"888-896","source":"Crossref","is-referenced-by-count":42,"title":["Deformation response of paired donor corneas to an air puff: Intact whole globe versus mounted corneoscleral rim"],"prefix":"10.1097","volume":"40","author":[{"given":"Kimberly M.","family":"Metzler","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashraf M.","family":"Mahmoud","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cynthia J.","family":"Roberts","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-5-20210210","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jcrs.2004.10.044","article-title":"Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.","volume":"31","author":"Luce","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R2-5-20210210","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1016\/j.ijleo.2008.03.026","article-title":"The biomechanical modeling of the refractive surgery.","volume":"120","author":"Asejczyk-Widlicka","year":"2009","journal-title":"Optik"},{"key":"R4-5-20210210","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.exer.2006.03.015","article-title":"Biomechanics and wound healing in the cornea.","volume":"83","author":"Dupps","year":"2006","journal-title":"Exp Eye Res"},{"key":"R5-5-20210210","doi-asserted-by":"crossref","first-page":"875","DOI":"10.3928\/1081597X-20090917-09","article-title":"Effects of altered corneal stiffness on native and postoperative LASIK corneal biomechanical behavior: a whole-eye finite element analysis.","volume":"25","author":"Roy","year":"2009","journal-title":"J Refract Surg"},{"key":"R6-5-20210210","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.clae.2008.12.009","article-title":"Comparison of corneal biomechanics in pre and post-refractive surgery and keratoconic eyes by Ocular Response Analyser.","volume":"32","author":"Shah","year":"2009","journal-title":"Cont Lens Anterior Eye"},{"key":"R8-5-20210210","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1016\/j.ajo.2005.12.007","article-title":"Central corneal thickness and corneal hysteresis associated with glaucoma damage.","volume":"141","author":"Congdon","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"R10-5-20210210","doi-asserted-by":"crossref","first-page":"2383","DOI":"10.1007\/s00417-013-2416-2","article-title":"Corneal biomechanics predict the outcome of selective laser trabeculoplasty in medically uncontrolled glaucoma.","volume":"251","author":"Hirneiss","year":"2013","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R11-5-20210210","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/j.ajo.2011.10.032","article-title":"Relationship between corneal biomechanical properties, central corneal thickness, and intraocular pressure across the spectrum of glaucoma.","volume":"153","author":"Kaushik","year":"2012","journal-title":"Am J Ophthalmol"},{"key":"R12-5-20210210","doi-asserted-by":"crossref","first-page":"081010","DOI":"10.1115\/1.3148462","article-title":"Assessment of the ocular response analyzer as a tool for intraocular pressure measurement.","volume":"131","author":"Elsheikh","year":"2009","journal-title":"J Biomech Eng"},{"key":"R13-5-20210210","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1007\/s00417-008-0864-x","article-title":"Factors affecting corneal hysteresis in normal eyes.","volume":"246","author":"Kamiya","year":"2008","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R14-5-20210210","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1016\/j.jcrs.2007.11.051","article-title":"Correlations between corneal hysteresis, intraocular pressure, and corneal central pachymetry.","volume":"34","author":"Touboul","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R16-5-20210210","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.jcrs.2004.09.031","article-title":"Influence of corneal biomechanical properties on intraocular pressure measurement; quantitative analysis.","volume":"31","author":"Liu","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R17-5-20210210","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1097\/IJG.0b013e3180640f40","article-title":"Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure.","volume":"16","author":"Broman","year":"2007","journal-title":"J Glaucoma"},{"key":"R21-5-20210210","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.ophtha.2006.06.047","article-title":"Los Angeles Latino Eye Study Group. Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry.","volume":"114","author":"Francis","year":"2007","journal-title":"Ophthalmology"},{"key":"R23-5-20210210","doi-asserted-by":"crossref","first-page":"1617","DOI":"10.1007\/s00417-010-1471-1","article-title":"Reproducibility of ocular response analyzer measurements and their correlation with central corneal thickness.","volume":"248","author":"Wasielica-Poslednik","year":"2010","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R24-5-20210210","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1016\/S0002-9394(37)90425-2","article-title":"Contribution to the theory and practice of tonometry.","volume":"20","author":"Friedenwald","year":"1937","journal-title":"Am J Ophthalmol"},{"key":"R25-5-20210210","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1111\/j.1442-9071.2012.02809.x","article-title":"Ocular rigidity: biomechanical role, in vivo measurements and clinical significance.","volume":"41","author":"Detorakis","year":"2013","journal-title":"Clin Exp Ophthalmol"},{"key":"R28-5-20210210","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1097\/IJG.0b013e3181aff419","article-title":"Modifications in corneal biomechanics and intraocular pressure after deep sclerectomy.","volume":"19","author":"Iordanidou","year":"2010","journal-title":"J Glaucoma"},{"key":"R29-5-20210210","doi-asserted-by":"crossref","first-page":"2096","DOI":"10.1016\/j.jcrs.2008.08.017","article-title":"Corneal biomechanical properties and intraocular pressure changes after phacoemulsification and intraocular lens implantation.","volume":"34","author":"Kucumen","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R34-5-20210210","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1016\/j.exer.2008.02.006","article-title":"Biomechanical properties of human and porcine corneas.","volume":"86","author":"Elsheikh","year":"2008","journal-title":"Exp Eye Res"},{"issue":"suppl 2","key":"R36-5-20210210","doi-asserted-by":"crossref","first-page":"S109","DOI":"10.1016\/j.survophthal.2007.08.004","article-title":"What biomechanical properties of the cornea are relevant for the clinician?","volume":"52","author":"Kotecha","year":"2007","journal-title":"Surv Ophthalmol"},{"key":"R37-5-20210210","doi-asserted-by":"crossref","first-page":"808","DOI":"10.3928\/1081-597X-20071001-11","article-title":"Determination of the modulus of elasticity of the human cornea.","volume":"23","author":"Elsheikh","year":"2007","journal-title":"J Refract Surg"},{"key":"R38-5-20210210","doi-asserted-by":"crossref","first-page":"1696","DOI":"10.1016\/j.jbiomech.2010.02.031","article-title":"Biaxial mechanical testing of human sclera.","volume":"43","author":"Eilaghi","year":"2010","journal-title":"J Biomech"},{"key":"R39-5-20210210","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1016\/j.exer.2010.02.010","article-title":"Regional variation in the biomechanical properties of the human sclera.","volume":"90","author":"Elsheikh","year":"2010","journal-title":"Exp Eye Res"},{"key":"R40-5-20210210","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/0014-4835(72)90139-X","article-title":"Nonlinear material properties of intact cornea and sclera.","volume":"14","author":"Woo","year":"1972","journal-title":"Exp Eye Res"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335014003976?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335014003976?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2014.02.032","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,15]],"date-time":"2021-06-15T18:17:21Z","timestamp":1623781041000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-201406000-00005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,6]]},"references-count":25,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2014]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2014.02.032","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2014,6]]}}}