{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T12:30:24Z","timestamp":1791549024961,"version":"4.3.4"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["jcrsjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2015,1]]},"DOI":"10.1016\/j.jcrs.2014.04.030","type":"journal-article","created":{"date-parts":[[2014,11,7]],"date-time":"2014-11-07T22:42:11Z","timestamp":1415400131000},"page":"90-97","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":19,"title":["Capsular bag performance of a hydrophobic acrylic 1-piece intraocular lens"],"prefix":"10.1097","volume":"41","author":[{"given":"Oliver","family":"Findl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nino","family":"Hirnschall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yutaro","family":"Nishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincenzo","family":"Maurino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alja","family":"Crnej","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-15-20210210","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1016\/j.jcrs.2004.04.063","article-title":"Change in IOL position and capsular bag size with an angulated intraocular lens early after cataract surgery.","volume":"31","author":"Koeppl","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R2-15-20210210","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/S0886-3350(03)00459-0","article-title":"Effect of haptic design on change in axial lens position after cataract surgery.","volume":"30","author":"Wirtitsch","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R3-15-20210210","doi-asserted-by":"crossref","first-page":"1974","DOI":"10.1016\/S0886-3350(02)02049-7","article-title":"Postoperative change in effective lens position of a 3-piece acrylic intraocular lens.","volume":"29","author":"Koeppl","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R4-15-20210210","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1016\/S0886-3350(98)80103-X","article-title":"Accurate determination of effective lens position and lens-capsule distance with 4 intraocular lenses.","volume":"24","author":"Findl","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R5-15-20210210","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","article-title":"Sources of error in intraocular lens power calculation.","volume":"34","author":"Norrby","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R6-15-20210210","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/S0886-3350(13)80699-2","article-title":"Effects of intraocular lens position errors on postoperative refractive error.","volume":"16","author":"Erickson","year":"1990","journal-title":"J Cataract Refract Surg"},{"key":"R7-15-20210210","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1111\/j.1475-1313.2005.00314.x","article-title":"A theoretical study of intraocular lens tilt and decentration on perceptual image quality.","volume":"25","author":"Turuwhenua","year":"2005","journal-title":"Ophthalmic Physiol Opt"},{"key":"R9-15-20210210","doi-asserted-by":"crossref","first-page":"683","DOI":"10.3928\/1081-597X-20021101-04","article-title":"A new intraocular lens design to reduce spherical aberration of pseudophakic eyes.","volume":"18","author":"Holladay","year":"2002","journal-title":"J Refract Surg"},{"key":"R10-15-20210210","doi-asserted-by":"crossref","first-page":"374","DOI":"10.3928\/1081-597X-20070401-10","article-title":"Theoretical comparison of aberration-correcting customized and aspheric intraocular lenses.","volume":"23","author":"Piers","year":"2007","journal-title":"J Refract Surg"},{"key":"R12-15-20210210","doi-asserted-by":"crossref","first-page":"1976","DOI":"10.1016\/j.jcrs.2008.07.029","article-title":"Effect of intraocular lens design on posterior capsule opacification.","volume":"34","author":"Buehl","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R13-15-20210210","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1016\/j.jcrs.2004.09.053","article-title":"Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification.","volume":"31","author":"Buehl","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R14-15-20210210","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1016\/j.ajo.2007.02.017","article-title":"Long-term effect of optic edge design in a silicone intraocular lens on posterior capsule opacification.","volume":"143","author":"Buehl","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"R15-15-20210210","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.ajo.2005.08.048","article-title":"Comparison of three methods of measuring corneal thickness and anterior chamber depth.","volume":"141","author":"Buehl","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"R16-15-20210210","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/S0886-3350(02)01822-9","article-title":"Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes.","volume":"29","author":"Kriechbaum","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R20-15-20210210","doi-asserted-by":"crossref","first-page":"1529","DOI":"10.1016\/j.jcrs.2010.03.043","article-title":"Reproducibility of intraocular lens decentration and tilt measurement using a clinical Purkinje meter.","volume":"36","author":"Nishi","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R21-15-20210210","doi-asserted-by":"crossref","first-page":"1988","DOI":"10.1016\/j.jcrs.2011.05.035","article-title":"Posterior capsule opacification and capsular bag performance of a microincision intraocular lens.","volume":"37","author":"Gangwani","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R23-15-20210210","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/S0886-3350(01)01228-7","article-title":"Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification.","volume":"28","author":"Buehl","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R24-15-20210210","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/S0886-3350(02)01509-2","article-title":"Comparison of 4 methods for quantifying posterior capsule opacification.","volume":"29","author":"Findl","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R25-15-20210210","doi-asserted-by":"crossref","first-page":"306","DOI":"10.3928\/1081597X-20080301-14","article-title":"Postoperative changes in refraction and anterior chamber depth in different multifocal intraocular lenses.","volume":"24","author":"Schmickler","year":"2008","journal-title":"J Refract Surg"},{"key":"R26-15-20210210","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.jcrs.2004.06.042","article-title":"Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule.","volume":"31","author":"Hayashi","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R27-15-20210210","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/j.ophtha.2005.10.064","article-title":"Prospective intrapatient comparison of 6.0-millimeter optic single-piece and 3-piece hydrophobic acrylic foldable intraocular lenses.","volume":"113","author":"Nejima","year":"2006","journal-title":"Ophthalmology"},{"key":"R28-15-20210210","doi-asserted-by":"crossref","first-page":"1768","DOI":"10.1016\/j.jcrs.2011.04.028","article-title":"Impact of intraocular lens haptic design and orientation on decentration and tilt.","volume":"37","author":"Crnej","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R29-15-20210210","doi-asserted-by":"crossref","first-page":"1915","DOI":"10.1016\/j.jcrs.2005.06.046","article-title":"Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.","volume":"31","author":"Kurz","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R30-15-20210210","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.1016\/j.ajo.2005.07.026","article-title":"Tilt and decentration of three-piece foldable high-refractive silicone and hydrophobic acrylic intraocular lenses with 6-mm optics in an intraindividual comparison.","volume":"140","author":"Baumeister","year":"2005","journal-title":"Am J Ophthalmol"},{"key":"R31-15-20210210","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/j.jcrs.2004.06.022","article-title":"Comparison of tilt and decentration of 1-piece and 3-piece hydrophobic acrylic intraocular lenses.","volume":"31","author":"Mutlu","year":"2005","journal-title":"J Cataract Refract Surg"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335014013091?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335014013091?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2014.04.030","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,21]],"date-time":"2022-04-21T19:58:10Z","timestamp":1650571090000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-201501000-00015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2014.04.030","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2015,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Capsular bag performance of a\u00a0hydrophobic acrylic 1-piece intraocular\u00a0lens","name":"articletitle","label":"Article Title"},{"value":"Journal of Cataract & Refractive Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcrs.2014.04.030","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}