{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T06:48:23Z","timestamp":1767854903020,"version":"3.49.0"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","license":[{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["jcrsjournal.org","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2015,9]]},"DOI":"10.1016\/j.jcrs.2015.08.009","type":"journal-article","created":{"date-parts":[[2015,10,26]],"date-time":"2015-10-26T05:03:29Z","timestamp":1445835809000},"page":"2010-2013","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":18,"title":["Anterior haptic flexing and in-the-bag subluxation of an accommodating intraocular lens due to excessive capsular bag contraction"],"prefix":"10.1097","volume":"41","author":[{"given":"Gregory D.","family":"Kramer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liliana","family":"Werner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tobias","family":"Neuhann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manfred","family":"Tetz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nick","family":"Mamalis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-29-20210210","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1016\/S0886-3350(13)80004-1","article-title":"Capsule contraction syndrome.","volume":"19","author":"Davison","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R2-29-20210210","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/S0886-3350(13)80287-8","article-title":"Progressive constriction of the anterior capsular opening following intact capsulorhexis.","volume":"19","author":"Hansen","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R3-29-20210210","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1097\/ICU.0b013e32834cd5be","article-title":"Intraocular lenses for presbyopia correction: past, present, and future.","volume":"23","author":"Lichtinger","year":"2012","journal-title":"Curr Opin Ophthalmol"},{"key":"R5-29-20210210","doi-asserted-by":"crossref","first-page":"1679","DOI":"10.1016\/j.ophtha.2006.12.017","article-title":"Visual performance results after Tetraflex accommodating intraocular lens implantation.","volume":"114","author":"Sanders","year":"2007","journal-title":"Ophthalmology"},{"key":"R6-29-20210210","doi-asserted-by":"crossref","first-page":"1711","DOI":"10.1016\/j.jcrs.2009.05.023","article-title":"Functional reading acuity and performance: comparison of 2 accommodating intraocular lenses.","volume":"35","author":"Brown","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R9-29-20210210","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1016\/j.jcrs.2009.09.042","article-title":"Capsule contraction syndrome with haptic deformation and flexion.","volume":"36","author":"Michael","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R11-29-20210210","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.1016\/j.jcrs.2010.06.029","article-title":"Clinicopathologic correlation of capsulorhexis phimosis with anterior flexing of single-piece hydrophilic acrylic intraocular lens haptics.","volume":"36","author":"Zaugg","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R12-29-20210210","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1007\/s10792-011-9425-0","article-title":"Capsular contraction syndrome following insertion of hydrophilic acrylic lens.","volume":"31","author":"Malik","year":"2011","journal-title":"Int Ophthalmol"},{"key":"R13-29-20210210","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/j.jcrs.2013.10.027","article-title":"Capsulorhexis phimosis with anterior flexing of an accommodating IOL: case report and histopathological analyses.","volume":"40","author":"Epstein","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R15-29-20210210","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.jcrs.2009.06.042","article-title":"Hyperopic shift from posterior migration of hydrophilic acrylic intraocular lens optic.","volume":"36","author":"Qatarneh","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R16-29-20210210","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.jcrs.2006.07.045","article-title":"Hyperopic shift with posterior bowing of a Collamer posterior chamber intraocular lens.","volume":"33","author":"Ozturk","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R17-29-20210210","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1016\/j.jcrs.2014.08.037","article-title":"Pathologic evidence of pseudoexfoliation in cases of in-the-bag intraocular lens subluxation or dislocation.","volume":"41","author":"Liu","year":"2015","journal-title":"J Cataract Refract Surg"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335015009980?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335015009980?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2015.08.009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,15]],"date-time":"2021-06-15T18:22:38Z","timestamp":1623781358000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-201509000-00029"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,9]]},"references-count":12,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2015]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2015.08.009","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2015,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Anterior haptic flexing and in-the-bag subluxation of an accommodating intraocular lens due to excessive capsular bag\u00a0contraction","name":"articletitle","label":"Article Title"},{"value":"Journal of Cataract & Refractive Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcrs.2015.08.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}