{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T00:00:21Z","timestamp":1793404821093,"version":"4.5.0"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","license":[{"start":{"date-parts":[[2017,9,1]],"date-time":"2017-09-01T00:00:00Z","timestamp":1504224000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["jcrsjournal.org","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2017,9]]},"DOI":"10.1016\/j.jcrs.2017.06.040","type":"journal-article","created":{"date-parts":[[2017,10,11]],"date-time":"2017-10-11T15:50:51Z","timestamp":1507737051000},"page":"1140-1148","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":65,"title":["Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation"],"prefix":"10.1097","volume":"43","author":[{"given":"Giacomo","family":"Savini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristian","family":"N\u00e6ser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Domenico","family":"Schiano-Lomoriello","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pietro","family":"Ducoli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-4-20210210","doi-asserted-by":"crossref","first-page":"2080","DOI":"10.1016\/j.jcrs.2012.08.036","article-title":"Contribution of posterior corneal astigmatism to total corneal astigmatism.","volume":"38","author":"Koch","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R2-4-20210210","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1016\/j.ajo.2008.12.020","article-title":"Accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement.","volume":"147","author":"Ho","year":"2009","journal-title":"Am J Ophthalmol"},{"key":"R3-4-20210210","doi-asserted-by":"crossref","first-page":"1645","DOI":"10.1016\/j.jcrs.2014.01.046","article-title":"Influence of posterior corneal astigmatism on total corneal astigmatism in eyes with moderate to high astigmatism.","volume":"40","author":"Savini","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R5-4-20210210","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.3109\/02713683.2014.898376","article-title":"Prediction of residual astigmatism after cataract surgery using swept source fourier domain optical coherence tomography.","volume":"39","author":"Hoffmann","year":"2014","journal-title":"Curr Eye Res"},{"key":"R6-4-20210210","doi-asserted-by":"crossref","first-page":"809","DOI":"10.3109\/02713683.2014.959708","article-title":"Impact of posterior corneal surface on toric intraocular lens (IOL) calculation.","volume":"40","author":"Preussner","year":"2015","journal-title":"Curr Eye Res"},{"key":"R7-4-20210210","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1016\/j.ophtha.2015.01.021","article-title":"Corneal thickness profile and posterior corneal astigmatism in normal corneas.","volume":"122","author":"Ueno","year":"2015","journal-title":"Ophthalmology"},{"key":"R9-4-20210210","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.jcrs.2015.11.036","article-title":"Effect of posterior corneal astigmatism on power calculation and alignment of toric intraocular lenses: comparison of methodologies.","volume":"42","author":"Reitblat","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R10-4-20210210","doi-asserted-by":"crossref","first-page":"699","DOI":"10.3928\/1081597X-20150928-03","article-title":"Comparison of methods to predict residual astigmatism after intraocular lens implantation.","volume":"31","author":"Abulafia","year":"2015","journal-title":"J Refract Surg"},{"key":"R11-4-20210210","doi-asserted-by":"crossref","first-page":"402","DOI":"10.3928\/1081597X-20130515-04","article-title":"A ray tracing approach to calculate toric intraocular lenses.","volume":"29","author":"Hoffmann","year":"2013","journal-title":"J Refract Surg"},{"key":"R13-4-20210210","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/S0002-9394(14)72213-5","article-title":"Assessment of radial aspheres by the Arc-Step algorithm as implemented by the Keratron keratoscope.","volume":"120","author":"Tripoli","year":"1995","journal-title":"Am J Ophthalmol"},{"key":"R14-4-20210210","doi-asserted-by":"crossref","first-page":"2072","DOI":"10.1016\/j.jcrs.2007.07.034","article-title":"Meridional analysis for calculating the expected spherocylindrical refraction in eyes with toric intraocular lenses.","volume":"33","author":"Fam","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R15-4-20210210","doi-asserted-by":"crossref","first-page":"1900","DOI":"10.1016\/j.jcrs.2013.04.047","article-title":"Influence of axial length and corneal power on the astigmatic power of toric intraocular lenses.","volume":"39","author":"Savini","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R18-4-20210210","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1016\/j.jcrs.2016.02.038","article-title":"New regression formula for toric intraocular lens calculations.","volume":"42","author":"Abulafia","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R20-4-20210210","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1097\/ICO.0000000000001224","article-title":"Estimating total corneal astigmatism from anterior corneal data.","volume":"36","author":"Naeser","year":"2017","journal-title":"Cornea"},{"key":"R21-4-20210210","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1046\/j.1475-1313.1999.00404.x","article-title":". Bivariate analysis of surgically induced regular astigmatism. Mathematical analysis and graphical display.","volume":"19","author":"Naeser","year":"1999","journal-title":"Ophthalmic Physiol Opt"},{"key":"R22-4-20210210","doi-asserted-by":"crossref","first-page":"394","DOI":"10.3928\/1081597X-20140429-01","article-title":"Evaluation of factors influencing the remaining astigmatism after toric intraocular lens implantation.","volume":"30","author":"Hirnschall","year":"2014","journal-title":"J Refract Surg"},{"key":"R23-4-20210210","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.jcrs.2012.09.014","article-title":"Fluctuations in corneal curvature limit predictability of intraocular lens power calculation.","volume":"39","author":"Norrby","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R24-4-20210210","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.ajo.2015.07.011","article-title":"Toric intraocular lens calculations using ratio of anterior to posterior corneal cylinder power.","volume":"160","author":"Eom","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"R25-4-20210210","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1016\/j.jcrs.2016.10.004","article-title":"Outcome of adjustment for posterior corneal curvature in toric intraocular lens calculation and selection.","volume":"42","author":"Goggin","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R26-4-20210210","doi-asserted-by":"crossref","first-page":"1684","DOI":"10.1364\/JOSAA.14.001684","article-title":"Anatomically accurate, finite model eye for optical modeling.","volume":"14","author":"Liou","year":"1997","journal-title":"J Opt Soc Am A"},{"key":"R27-4-20210210","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1136\/bjophthalmol-2015-307474","article-title":"Corneal power measured with a rotating Scheimpflug camera.","volume":"100","author":"Naeser","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"R28-4-20210210","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1097\/ICO.0000000000001117","article-title":"Total corneal astigmatism measurements: agreement between 2 Scheimpflug cameras.","volume":"36","author":"Savini","year":"2017","journal-title":"Cornea"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335017305497?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335017305497?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2017.06.040","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,15]],"date-time":"2021-06-15T14:30:25Z","timestamp":1623767425000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-201709000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9]]},"references-count":22,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2017.06.040","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2017,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation","name":"articletitle","label":"Article Title"},{"value":"Journal of Cataract & Refractive Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcrs.2017.06.040","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 ASCRS and ESCRS Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}