{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T07:23:03Z","timestamp":1780471383248,"version":"3.54.1"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2018,2,1]],"date-time":"2018-02-01T00:00:00Z","timestamp":1517443200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["jcrsjournal.org","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,2]]},"DOI":"10.1016\/j.jcrs.2017.11.008","type":"journal-article","created":{"date-parts":[[2018,3,8]],"date-time":"2018-03-08T04:59:26Z","timestamp":1520485166000},"page":"168-174","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":25,"title":["New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism"],"prefix":"10.1097","volume":"44","author":[{"given":"Carmen","family":"Canovas","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aixa","family":"Alarcon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Ros\u00e9n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanjeev","family":"Kasthurirangan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph J.K.","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Douglas D.","family":"Koch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patricia","family":"Piers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R3-9-20210210","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1097\/01.ico.0000126315.05519.0b","article-title":"Evaluation of normal corneas using the scanning-slit topographypachymetry system.","volume":"23","author":"Modis","year":"2004","journal-title":"Cornea"},{"key":"R4-9-20210210","doi-asserted-by":"crossref","first-page":"993","DOI":"10.1016\/j.visres.2005.09.021","article-title":"The shape of the anterior and posterior surface of the aging human cornea.","volume":"46","author":"Dubbelman","year":"2006","journal-title":"Vision Res"},{"key":"R5-9-20210210","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1111\/j.1475-1313.2008.00632.x","article-title":"Correlation between the dioptric power, astigmatism and surface shape of the anterior and posterior corneal surfaces.","volume":"29","author":"Mas","year":"2009","journal-title":"Ophthalmic Physiol Opt"},{"key":"R6-9-20210210","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1016\/j.ajo.2008.12.020","article-title":"Accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement.","volume":"147","author":"Ho","year":"2009","journal-title":"Am J Ophthalmol"},{"key":"R7-9-20210210","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1097\/ICO.0b013e31827bf898","article-title":"Correlation of the corneal toricity between anterior and posterior corneal surfaces in the normal human eye.","volume":"32","author":"Montalban","year":"2013","journal-title":"Cornea"},{"key":"R8-9-20210210","doi-asserted-by":"crossref","first-page":"2080","DOI":"10.1016\/j.jcrs.2012.08.036","article-title":"Contribution of posterior corneal astigmatism to total corneal astigmatism.","volume":"38","author":"Koch","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R9-9-20210210","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1016\/j.jcrs.2016.02.038","article-title":"New regression formula for toric intraocular lens calculations.","volume":"42","author":"Abulafia","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R10-9-20210210","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.ajo.2015.07.011","article-title":"Toric intraocular lens calculations using ratio of anterior to posterior corneal cylinder power.","volume":"160","author":"Eom","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"R11-9-20210210","doi-asserted-by":"crossref","first-page":"98","DOI":"10.3928\/1081597X-20150122-04","article-title":"Adjustment of anterior corneal astigmatism values to incorporate the likely effect of posterior corneal curvature for toric intraocular lens calculation.","volume":"31","author":"Goggin","year":"2015","journal-title":"J Refract Surg"},{"key":"R12-9-20210210","doi-asserted-by":"crossref","first-page":"1803","DOI":"10.1016\/j.jcrs.2013.06.027","article-title":"Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism.","volume":"39","author":"Koch","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R13-9-20210210","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.ophtha.2014.06.027","article-title":"Clinical outcomes of TECNIS toric intraocular lens implantation after cataract removal in patients with corneal astigmatism.","volume":"122","author":"Waltz","year":"2015","journal-title":"Ophthalmology"},{"key":"R14-9-20210210","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","article-title":"A three-part system for refining intraocular lens power calculations.","volume":"14","author":"Holladay","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"R15-9-20210210","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1046\/j.1475-1313.1999.00404.x","article-title":"Hjortdal J Bivariate analysis of surgically induced regular astigmatism. Mathematical analysis and graphical display.","volume":"19","author":"Naeser","year":"1999","journal-title":"Ophthalmic Physiol Opt"},{"key":"R16-9-20210210","doi-asserted-by":"crossref","first-page":"643","DOI":"10.3928\/1081597X-20110317-03","article-title":"AcrySof IQ toric IOL implantation combined with limbal relaxing incision during cataract surgery for eyes with astigmatism 2.50 D.","volume":"27","author":"Ouchi","year":"2011","journal-title":"J Refract Surg"},{"key":"R17-9-20210210","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1097\/ICU.0000000000000225","article-title":"Intraocular lens alignment methods.","volume":"27","author":"Thulasi","year":"2016","journal-title":"Curr Opin Ophthalmol"},{"key":"R18-9-20210210","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1136\/bjophthalmol-2015-306656","article-title":"Factors influencing 1-year rotational stability of AcrySof toric intraocular lenses.","volume":"100","author":"Zhu","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"R20-9-20210210","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1016\/j.jcrs.2014.08.036","article-title":"Prediction of refractive outcomes with toric intraocular lens implantation.","volume":"41","author":"Abulafia","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R21-9-20210210","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.jcrs.2015.11.036","article-title":"Effect of posterior corneal astigmatism on power calculation and alignment of toric intraocular lenses: comparison of methodologies.","volume":"42","author":"Reitblat","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R22-9-20210210","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.jcrs.2016.12.031","article-title":"Comparison of astigmatic prediction errors associated with new calculation methods for toric intraocular lenses.","volume":"43","author":"Ferreira","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R24-9-20210210","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.jcjo.2014.08.003","article-title":"Effect of effective lens position on cylinder power of toric intraocular lenses.","volume":"50","author":"Eom","year":"2015","journal-title":"Can J Ophthalmol"},{"key":"R26-9-20210210","doi-asserted-by":"crossref","first-page":"1977","DOI":"10.1007\/s00417-016-3446-3","article-title":"Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.","volume":"254","author":"Eom","year":"2016","journal-title":"Graefes Arch Clin Exp Ophthalmol"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335018300786?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0886335018300786?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.jcrs.2017.11.008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,15]],"date-time":"2021-06-15T18:31:43Z","timestamp":1623781903000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/02158034-201802000-00009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1016\/j.jcrs.2017.11.008","relation":{},"ISSN":["0886-3350"],"issn-type":[{"value":"0886-3350","type":"print"}],"subject":[],"published":{"date-parts":[[2018,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism","name":"articletitle","label":"Article Title"},{"value":"Journal of Cataract & Refractive Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcrs.2017.11.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 ASCRS and ESCRS Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}