{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T04:40:51Z","timestamp":1775623251690,"version":"3.50.1"},"reference-count":12,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Virology"],"published-print":{"date-parts":[[2021,1]]},"DOI":"10.1016\/j.jcv.2020.104712","type":"journal-article","created":{"date-parts":[[2020,12,4]],"date-time":"2020-12-04T12:31:55Z","timestamp":1607085115000},"page":"104712","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":63,"special_numbering":"C","title":["Evaluation of rapid antigen detection kit from the WHO Emergency Use List for detecting SARS-CoV-2"],"prefix":"10.1016","volume":"134","author":[{"given":"Gannon C.K.","family":"Mak","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephen S.Y.","family":"Lau","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kitty K.Y.","family":"Wong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nancy L.S.","family":"Chow","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.S.","family":"Lau","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edman T.K.","family":"Lam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rickjason C.W.","family":"Chan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominic N.C.","family":"Tsang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcv.2020.104712_bib0005","series-title":"Interim Guidance","article-title":"Antigen-detection in the diagnosis of SARS-CoV-2 infection using rapid immunoassays","author":"WHO","year":"2020"},{"issue":"1","key":"10.1016\/j.jcv.2020.104712_bib0010","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1042\/EBC20150012","article-title":"Lateral flow assays","volume":"60","author":"Koczula","year":"2016","journal-title":"Essays Biochem."},{"key":"10.1016\/j.jcv.2020.104712_bib0015","doi-asserted-by":"crossref","DOI":"10.1016\/j.jcv.2020.104654","article-title":"Urgent need of rapid tests for SARS CoV-2 antigen detection: evaluation of the SD-Biosensor antigen test for SARS-CoV-2","author":"Cerutti","year":"2020","journal-title":"J. Clin. Virol."},{"key":"10.1016\/j.jcv.2020.104712_bib0020","article-title":"SARS CoV-2 surveillance and exposure in the perioperative setting with universal testing and personal protective equipment (PPE) policies","author":"Aslam","year":"2020","journal-title":"Clin. Infect. Dis."},{"key":"10.1016\/j.jcv.2020.104712_bib0025","article-title":"Performance of a novel diagnostic assay for rapid SARS-CoV-2 antigen detection in nasopharynx samples","author":"Liotti","year":"2020","journal-title":"Clin. Microbiol. Infect."},{"key":"10.1016\/j.jcv.2020.104712_bib0030","series-title":"WHO Emergency Use Listing for in Vitro Diagnostics (IVDs) Detecting SARS-CoV-2","author":"WHO","year":"2020"},{"key":"10.1016\/j.jcv.2020.104712_bib0035","doi-asserted-by":"crossref","DOI":"10.1016\/j.jcv.2020.104500","article-title":"Evaluation of rapid antigen test for detection of SARS-CoV-2 virus","volume":"129","author":"Mak","year":"2020","journal-title":"J. Clin. Virol."},{"key":"10.1016\/j.jcv.2020.104712_bib0040","doi-asserted-by":"crossref","DOI":"10.1016\/j.jcv.2020.104684","article-title":"Analytical sensitivity and clinical sensitivity of the three rapid antigen detection kits for detection of SARS-CoV-2 virus","volume":"133","author":"Mak","year":"2020","journal-title":"J. Clin. Virol."},{"key":"10.1016\/j.jcv.2020.104712_bib0045","doi-asserted-by":"crossref","DOI":"10.1016\/j.jcv.2020.104659","article-title":"Panbio antigen rapid test is reliable to diagnose SARS-CoV-2 infection in the first 7 days after the onset of symptoms","author":"Linares","year":"2020","journal-title":"J. Clin. Virol."},{"key":"10.1016\/j.jcv.2020.104712_bib0050","article-title":"Evaluation of the Panbio Covid-19 rapid antigen detection test device for the screening of patients with Covid-19","author":"Fenollar","year":"2020","journal-title":"J. Clin. Microbiol."},{"key":"10.1016\/j.jcv.2020.104712_bib0055","article-title":"Real-life validation of the Panbio COVID-19 Antigen Rapid Test (Abbott) in community-dwelling subjects with symptoms of potential SARS-CoV-2 infection","author":"Gremmels","year":"2020","journal-title":"Preprints"},{"key":"10.1016\/j.jcv.2020.104712_bib0060","series-title":"SARS-CoV-2 Antigen Detecting Rapid Diagnostic Test Implementation Projects","author":"WHO","year":"2020"}],"container-title":["Journal of Clinical Virology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1386653220304546?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1386653220304546?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,25]],"date-time":"2025-10-25T03:13:06Z","timestamp":1761361986000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1386653220304546"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":12,"alternative-id":["S1386653220304546"],"URL":"https:\/\/doi.org\/10.1016\/j.jcv.2020.104712","relation":{},"ISSN":["1386-6532"],"issn-type":[{"value":"1386-6532","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of rapid antigen detection kit from the WHO Emergency Use List for detecting SARS-CoV-2","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Virology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcv.2020.104712","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"104712"}}