{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T08:23:45Z","timestamp":1787905425637,"version":"build-2784847793"},"reference-count":42,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,2,14]],"date-time":"2024-02-14T00:00:00Z","timestamp":1707868800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Dentistry"],"published-print":{"date-parts":[[2024,4]]},"DOI":"10.1016\/j.jdent.2024.104885","type":"journal-article","created":{"date-parts":[[2024,2,10]],"date-time":"2024-02-10T19:10:36Z","timestamp":1707592236000},"page":"104885","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":18,"special_numbering":"C","title":["Novel complete-arch pillar system (CAPS) to register implant position and maxillomandibular relationship in one single visit"],"prefix":"10.1016","volume":"143","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9760-0114","authenticated-orcid":false,"given":"Philippe","family":"Nuytens","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6184-6654","authenticated-orcid":false,"given":"Francesco","family":"Grande","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6194-0931","authenticated-orcid":false,"given":"Rani","family":"D'haese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3989-4163","authenticated-orcid":false,"given":"Ziad","family":"Salameh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7422-1549","authenticated-orcid":false,"given":"Luca","family":"Lepidi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jdent.2024.104885_bib0001","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1111\/jerd.12993","article-title":"A guide for maximizing the accuracy of intraoral digital scans: part 2\u2013patient factors","volume":"35","author":"Revilla-Le\u00f3n","year":"2022","journal-title":"J. Esthet. Restor. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0002","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1111\/jopr.13211","article-title":"Digital vs conventional implant impressions: a systematic review and meta-analysis","volume":"29","author":"Papaspyridakos","year":"2020","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2024.104885_bib0003","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1016\/j.prosdent.2021.09.001","article-title":"Factors that influence the accuracy of intraoral scanning of total edentulous arches rehabilitated with multiple implants: a systematic review","volume":"129","author":"Carneiro Pereira","year":"2023","journal-title":"J. Prosth. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0004","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.prosdent.2019.06.014","article-title":"Digital scanning for complete-arch implant-supported restorations: a systematic review","volume":"124","author":"Wulfman","year":"2020","journal-title":"J. Prosth. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0005","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1111\/jopr.13749","article-title":"Intraoral digital implant scans: parameters to improve accuracy","volume":"32","author":"Revilla-Le\u00f3n","year":"2023","journal-title":"J Prosthodont"},{"key":"10.1016\/j.jdent.2024.104885_bib0006","doi-asserted-by":"crossref","first-page":"731","DOI":"10.11607\/jomi.9248","article-title":"Effect of scan pattern on the accuracy of complete-arch digital implant impressions with two intraoral scanners","volume":"37","author":"Li","year":"2022","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"10.1016\/j.jdent.2024.104885_bib0007","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.prosdent.2019.02.008","article-title":"Effect of scan pattern on complete-arch scans with 4 digital scanners","volume":"123","author":"Latham","year":"2020","journal-title":"J. Prosth. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0008","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1111\/jopr.13774","article-title":"Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: a systematic review","volume":"32","author":"G\u00f3mez-Polo","year":"2023","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2024.104885_bib0009","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1111\/clr.13273","article-title":"The accuracy of different dental impression techniques for implant-supported dental prostheses: a systematic review and meta-analysis","volume":"29","author":"Fl\u00fcgge","year":"2018","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2024.104885_bib0010","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1111\/jopr.13135","article-title":"Clinical study of the influence of ambient light scanning conditions on the accuracy (trueness and precision) of an intraoral scanner","volume":"29","author":"Revilla-Le\u00f3n","year":"2020","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2024.104885_bib0011","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1111\/jopr.13358","article-title":"Influence of liquid on the tooth surface on the accuracy of intraoral scanners: an in vitro study","volume":"31","author":"Chen","year":"2022","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2024.104885_bib0012","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1016\/j.prosdent.2021.08.018","article-title":"Techniques to improve the accuracy of complete-arch implant intraoral digital scans: a systematic review","volume":"129","author":"Paratelli","year":"2023","journal-title":"J. Prosth. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0013","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1111\/jopr.13750","article-title":"Additively manufactured devices with varying designs and sizes for acquiring initial intraoral implant scans","volume":"32","author":"Guirao","year":"2023","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2024.104885_bib0014","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1111\/clr.13598","article-title":"Improved scanning accuracy with newly designed scan bodies: an in vitro study comparing digital versus conventional impression techniques for complete-arch implant rehabilitation","volume":"31","author":"Huang","year":"2020","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2024.104885_bib0015","first-page":"128","article-title":"Continuous Scan Strategy (CSS): a novel technique to improve the accuracy of intraoral digital impressions","volume":"28","author":"Imburgia","year":"2020","journal-title":"Eur. J. Prosthodont. Restor. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0016","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1111\/jerd.13070","article-title":"Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant-supported full arch fixed prosthesis","volume":"35","author":"Ashraf","year":"2023","journal-title":"J. Esthet. Restor. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0017","first-page":"19","article-title":"Effect of splinting scan bodies on trueness of complete-arch implant impression using different intraoral scanners: an in vitro study","volume":"26","author":"Retana","year":"2023","journal-title":"Int. J. Comput. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0018","article-title":"Calibrated splinting framework for complete-arch intraoral implant digital scans manufactured by combining milled and additively manufacturing technologies: a dental technique","author":"Llansana","year":"2022","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0019","article-title":"Accuracy of intraoral scan with prefabricated aids and stereophotogrammetry compared with open tray impressions for complete-arch implant-supported prosthesis: a clinical study","author":"Fu","year":"2023","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2024.104885_bib0020","article-title":"Registration of maxillomandibular relationship through a fully digital workflow for complete-mouth rehabilitation with screw-retained fixed implant-supported prostheses: a clinical report","author":"Ramadan","year":"2023","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0021","doi-asserted-by":"crossref","first-page":"672","DOI":"10.5005\/jp-journals-10024-1597","article-title":"A time-saving method for transferring occlusal vertical dimension and centric relation of complete denture to a full-arch implant prosthesis","volume":"15","author":"Parnia","year":"2014","journal-title":"J. Contemp. Dent. Pract."},{"key":"10.1016\/j.jdent.2024.104885_bib0022","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1016\/j.prosdent.2020.04.008","article-title":"Digital maxillomandibular relationship registration for an edentulous maxilla: a dental technique","volume":"125","author":"Griseto","year":"2021","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0023","doi-asserted-by":"crossref","first-page":"2882","DOI":"10.3390\/jcm11102882","article-title":"Reliability and time efficiency of digital vs. analog bite registration technique for the manufacture of full-arch fixed implant prostheses","volume":"11","author":"Nuytens","year":"2022","journal-title":"J. Clin. Med."},{"key":"10.1016\/j.jdent.2024.104885_bib0024","article-title":"Face oriented digital workflow for transferring intraoral and extraoral data of edentulous arch rehabilitated with multiple implants: a clinical technique","author":"Nuytens","year":"2023","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0025","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1067\/mpr.2001.114279","article-title":"Use of a patient's old complete denture to determine vertical dimension of occlusion","volume":"85","author":"Bissasu","year":"2001","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0026","article-title":"Impact of intraoral scanner, scanning strategy, and scanned arch on the scan accuracy of edentulous arches: an in vitro study","author":"Jamjoom","year":"2023","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0027","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/s12548-011-0014-7","article-title":"Myostabilized centric relation","volume":"4","author":"Orthlieb","year":"2011","journal-title":"J. Stomat. Occ. Med."},{"key":"10.1016\/j.jdent.2024.104885_bib0028","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.prosdent.2005.06.012","article-title":"Comparing condylar positions achieved through bimanual manipulation to condylar positions achieved through masticatory muscle contraction against an anterior deprogrammer: a pilot study","volume":"94","author":"McKee","year":"2005","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0029","article-title":"Misfit simulation on implant prostheses with different combinations of engaging and nonengaging titanium bases. Part 2: Screw resistance test","author":"Rutkunas","year":"2022","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0030","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/S0022-3913(99)70229-5","article-title":"Clinical methods for evaluating implant framework fit","volume":"81","author":"Kan","year":"1999","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0031","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1034\/j.1600-0501.1995.060306.x","article-title":"Accuracy of implant-supported prostheses in the edentulous jaw: analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique","volume":"6","author":"Jemt","year":"1995","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2024.104885_bib0032","article-title":"Occlusal considerations for full-arch implant-supported prostheses: a guideline","volume":"2","author":"Yoon","year":"2022","journal-title":"Dent. Rev."},{"key":"10.1016\/j.jdent.2024.104885_bib0033","doi-asserted-by":"crossref","first-page":"323","DOI":"10.11607\/prd.3295","article-title":"Increasing the vertical dimension of occlusion: A multicenter retrospective clinical comparative study on 100 patients with fixed tooth-supported, mixed, and implant-supported full-arch rehabilitations","volume":"38","author":"Fabbri","year":"2018","journal-title":"Int. J. Periodontics Restorative Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0034","first-page":"497","article-title":"Altered vertical dimension of occlusion: a comparative retrospective pilot study of tooth- and implant-supported restorations","volume":"24","author":"Ormianer","year":"2009","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"10.1016\/j.jdent.2024.104885_bib0035","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1016\/0022-3913(68)90083-8","article-title":"The consistency of the swallowing technique in determining occlusal vertical relation in edentulous patients","volume":"19","author":"Ismail","year":"1968","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0036","doi-asserted-by":"crossref","first-page":"123","DOI":"10.2298\/VSP1502123I","article-title":"Determination of vertical dimension of occlusion by using the phonetic vowel \u201cO\u201d and \u201cE","volume":"72","author":"Marko","year":"2015","journal-title":"Vojnosanit Pregl"},{"key":"10.1016\/j.jdent.2024.104885_bib0037","unstructured":"G.A. Zarb, G.E. Carlsson, C.L. Bolender, Boucher's prosthodontic treatment for edentulous patients, eleventh ed., Mosby, St. Louis, 1997."},{"key":"10.1016\/j.jdent.2024.104885_bib0038","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/0022-3913(88)90182-5","article-title":"Determination of occlusal vertical dimension: a literature review","volume":"59","author":"Fayz","year":"1988","journal-title":"J Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0039","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104702","article-title":"Effect of novel prefabricated auxiliary devices attaching to scan bodies on the accuracy of intraoral scanning of complete-arch with multiple implants: an in-vitro study","volume":"138","author":"Wu","year":"2023","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0040","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.prosdent.2019.01.003","article-title":"Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses","volume":"123","author":"Mizumoto","year":"2020","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2024.104885_bib0041","doi-asserted-by":"crossref","first-page":"369","DOI":"10.4047\/jap.2022.14.6.369","article-title":"Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration","volume":"14","author":"Mei","year":"2022","journal-title":"J. Adv. Prosthodont."},{"key":"10.1016\/j.jdent.2024.104885_bib0042","article-title":"E, Evaluation of repeatability of different alignment methods to obtain digital interocclusal records: an in vitro study","author":"Garikano","year":"2022","journal-title":"J. Prosthet. Dent."}],"container-title":["Journal of Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300571224000551?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300571224000551?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,4]],"date-time":"2025-10-04T00:40:03Z","timestamp":1759538403000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0300571224000551"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":42,"alternative-id":["S0300571224000551"],"URL":"https:\/\/doi.org\/10.1016\/j.jdent.2024.104885","relation":{},"ISSN":["0300-5712"],"issn-type":[{"value":"0300-5712","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Novel complete-arch pillar system (CAPS) to register implant position and maxillomandibular relationship in one single visit","name":"articletitle","label":"Article Title"},{"value":"Journal of Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jdent.2024.104885","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"104885"}}