{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T13:16:33Z","timestamp":1793106993500,"version":"4.5.0"},"reference-count":55,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T00:00:00Z","timestamp":1760313600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Dentistry"],"published-print":{"date-parts":[[2025,12]]},"DOI":"10.1016\/j.jdent.2025.106180","type":"journal-article","created":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T22:37:38Z","timestamp":1760395058000},"page":"106180","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Influence of three coded healing abutment design on intraoral scan accuracy: a comparative in vitro study"],"prefix":"10.1016","volume":"163","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9157-1903","authenticated-orcid":false,"given":"Bel\u00e9n","family":"Mor\u00f3n-Conejo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana Federica","family":"Stran-Lo Giudice","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6580-1835","authenticated-orcid":false,"given":"Mar\u00eda Paz","family":"Salido","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1810-3724","authenticated-orcid":false,"given":"Santiago","family":"Berrendero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristina","family":"Madrigal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9716-1385","authenticated-orcid":false,"given":"Guillermo","family":"Prad\u00edes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jdent.2025.106180_bib0001","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/j.prosdent.2017.10.029","article-title":"Intraoral scan bodies in implant dentistry: a systematic review","volume":"120","author":"Mizumoto","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0002","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1016\/j.sdentj.2023.08.006","article-title":"Accuracy of digitally coded healing abutments: a systematic review","volume":"35","author":"Talesara","year":"2013","journal-title":"Saudi. Dent. J."},{"key":"10.1016\/j.jdent.2025.106180_bib0003","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1111\/clr.13273","article-title":"The accuracy of different dental impression techniques for implant-supported dental prostheses: a systematic review and meta-analysis","volume":"29","author":"Fl\u00fcgge","year":"2018","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2025.106180_bib0004","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1007\/s00784-011-0564-5","article-title":"Digital evaluation of the reproducibility of implant scanbody fit\u2014An in vitro study","volume":"16","author":"Stimmelmayr","year":"2012","journal-title":"Clin. Oral Invest."},{"key":"10.1016\/j.jdent.2025.106180_bib0005","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1111\/jopr.13131","article-title":"Impact of different scan bodies and scan strategies on the accuracy of digital implant impressions assessed with an intraoral scanner: an In vitro study","volume":"29","author":"Motel","year":"2020","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2025.106180_bib0006","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.prosdent.2022.09.010","article-title":"Magnitude of misfit threshold in implant-supported restorations: a systematic review","volume":"132","author":"Abdelrehim","year":"2014","journal-title":"J. Proshtet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0007","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1067\/mpr.2002.124589","article-title":"Effect of splinting and interproximal contact tightness on load transfer by implant restorations","volume":"87","author":"Guichet","year":"2002","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0008","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1111\/clr.12490","article-title":"New 3D technologies applied to assess the long-term clinical effects of misfit of the full jaw fixed prosthesis on dental implants","volume":"26","author":"Jokstad","year":"2015","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2025.106180_bib0009","first-page":"128","article-title":"Continuous scan strategy (CSS): a novel technique to improve the accuracy of intraoral digital impressions","volume":"28","author":"Imburgia","year":"2020","journal-title":"Eur. J. Prosthodont. Restor. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0010","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1111\/cid.12681","article-title":"CAD\/CAM implant crowns in a digital workflow: five-year follow-up of a prospective clinical trial","volume":"21","author":"Joda","year":"2019","journal-title":"Clin. Implant Dent. Rel. Res."},{"key":"10.1016\/j.jdent.2025.106180_bib0011","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2022.104095","article-title":"Influence of customized over-scan body rings on the intraoral scanning effectiveness of a multiple implant edentulous mandibular model","volume":"122","author":"Garc\u00eda-Mart\u00ednez","year":"2022","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0012","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105152","article-title":"Intraoral scanners in implant prosthodontics. A narrative review","volume":"148","author":"Rutk\u016bnas","year":"2024","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0013","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1186\/s12903-020-01254-9","article-title":"Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study","volume":"20","author":"Mangano","year":"2020","journal-title":"BMC. Oral Health"},{"key":"10.1016\/j.jdent.2025.106180_bib0014","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1111\/jopr.13162","article-title":"Digital versus conventional full-arch implant impressions: a prospective study on 16 edentulous maxillae","volume":"29","author":"Chochlidakis","year":"2020","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2025.106180_bib0015","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1111\/cid.12919","article-title":"The effect of scanner type and scan body position on the accuracy of complete-arch digital implant scans","volume":"22","author":"\u00c7akmak","year":"2020","journal-title":"Clin. ImPlant Dent. Relat. Res."},{"key":"10.1016\/j.jdent.2025.106180_bib0016","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105605","article-title":"Implant-supported full-arch fixed dental prostheses manufactured through a direct digital workflow using a calibrated splinting framework: a retrospective clinical study","volume":"154","author":"Rustichini","year":"2025","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0017","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1016\/j.prosdent.2024.01.017","article-title":"Influence of connected and nonconnected calibrated frameworks on the accuracy of complete arch implant scans obtained by using four intraoral scanners, a desktop scanner, and a photogrammetry system","volume":"134","author":"Revilla-Le\u00f3n","year":"2025","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0018","doi-asserted-by":"crossref","DOI":"10.3390\/jcm11102882","article-title":"Reliability and time efficiency of digital vs. Analog bite registration technique for the manufacture of full-arch fixed implant prostheses","volume":"11","author":"Nuytens","year":"2022","journal-title":"J. Clin. Med."},{"key":"10.1016\/j.jdent.2025.106180_bib0019","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104741","article-title":"Full-arch restoration with the NEXUS IOS\u00ae system: a retrospective clinical evaluation of 37 restorations after a one year of follow-up","volume":"139","author":"Klein","year":"2023","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0020","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1111\/jerd.13074","article-title":"Characteristics of intraoral scan bodies and their influence on impression accuracy: a systematic review","volume":"25","author":"Pachiou","year":"2023","journal-title":"J. Esthet. Restor. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0021","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1016\/j.prosdent.2023.01.018","article-title":"Effect of supramucosal height of a scan body and implant angulation on the accuracy of intraoral scanning: an in vitro study","volume":"131","author":"Sicilia","year":"2024","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0022","doi-asserted-by":"crossref","first-page":"2174","DOI":"10.3390\/jcm9072174","article-title":"Congruence between meshes and library files of implant scanbodies: an In vitro study comparing five intraoral scanners","volume":"9","author":"Mangano","year":"2020","journal-title":"JCM"},{"key":"10.1016\/j.jdent.2025.106180_bib0023","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105336","article-title":"Effects of the intraoral scanner and implant library on the trueness of digital impressions in the full-arch implant scan: a comparative in vitro study","volume":"150","author":"Hauschild","year":"2024","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0024","doi-asserted-by":"crossref","first-page":"591","DOI":"10.11607\/ijp.7379","article-title":"Tolerances in the production of six different implant scan bodies: a comparative study","volume":"34","author":"Lerner","year":"2021","journal-title":"Int. J. Prosthodont."},{"key":"10.1016\/j.jdent.2025.106180_bib0025","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1111\/jopr.13749","article-title":"Intraoral digital implant scans: parameters to improve accuracy","volume":"32","author":"Revilla-Le\u00f3n","year":"2023","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2025.106180_bib0026","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1007\/s00784-019-02965-2","article-title":"Accuracy of full-arch digital impressions: an in vitro and in vivo comparison","volume":"24","author":"Keul","year":"2020","journal-title":"Clin. Oral Invest."},{"key":"10.1016\/j.jdent.2025.106180_bib0027","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105973","article-title":"Factors influencing the intraoral implant scan accuracy: a review of the literature","volume":"161","author":"Grande","year":"2025","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0028","article-title":"One-time versus repeated abutment connection for platform-switched implant: a systematic review and meta-analysis","volume":"12","author":"Wang","year":"2017","journal-title":"PLoS. One"},{"key":"10.1016\/j.jdent.2025.106180_bib0029","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1111\/clr.12818","article-title":"The effect of one-time abutment placement on interproximal bone levels and peri-implant soft tissues: a prospective randomized clinical trial","volume":"28","author":"Molina","year":"2017","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2025.106180_bib0030","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1111\/cid.12541","article-title":"A comparative study of encode protocol versus conventional protocol for restoring single implants: one-year prospective randomized controlled clinical trial","volume":"19","author":"Abduo","year":"2017","journal-title":"Clin. Implant Dent. Rel. Res."},{"key":"10.1016\/j.jdent.2025.106180_bib0031","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105465","article-title":"A novel coded healing abutment for a simplified digital workflow: a retrospective clinical study on 103 patients with a one year follow-up","volume":"152","author":"Mouhyi","year":"2025","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0032","doi-asserted-by":"crossref","first-page":"609","DOI":"10.11607\/ijp.6707","article-title":"Implant-supported three-unit fixed dental prosthesis using coded healing abutments and fabricated using a digital workflow: a 1-year prospective case series study","volume":"33","author":"Pol","year":"2020","journal-title":"Int. J. Prosthodont."},{"key":"10.1016\/j.jdent.2025.106180_bib0033","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/S0022-3913(13)00073-5","article-title":"Using digitally coded healing abutments and an intraoral scanner to fabricate implant-supported, cement-retained restorations","volume":"109","author":"Nayyar","year":"2013","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0034","doi-asserted-by":"crossref","DOI":"10.1111\/j.1708-8208.2011.00344.x","article-title":"The accuracy of an implant impression technique using digitally coded healing abutments","volume":"14","author":"Eliasson","year":"2012","journal-title":"Clin. Implant Dent. Rel. Res"},{"key":"10.1016\/j.jdent.2025.106180_bib0035","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1563\/aaid-joi-D-19-00150","article-title":"Encode protocol versus conventional protocol for single-implant restoration: a prospective 2-year follow-up randomized controlled trial","volume":"47","author":"Abduo","year":"2021","journal-title":"J Oral Implant."},{"key":"10.1016\/j.jdent.2025.106180_bib0036","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1016\/j.prosdent.2020.06.042","article-title":"Accuracy of implant impression techniques with a scannable healing abutment","volume":"28","author":"Jung","year":"2022","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0037","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/S0022-3913(13)60346-7","article-title":"An in vitro comparison of the accuracy of implant impressions with coded healing abutments and different implant angulations","volume":"110","author":"Al-Abdullah","year":"2013","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0038","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1563\/aaid-joi-D-22-00187","article-title":"The use of a coded healing abutment in the restoration of a single, immediately placed implant in the esthetic zone: a clinical case report","volume":"49","author":"Attar","year":"2023","journal-title":"J. Oral Implant."},{"key":"10.1016\/j.jdent.2025.106180_bib0039","doi-asserted-by":"crossref","DOI":"10.1016\/j.prosdent.2025.03.035","article-title":"Complete arch implant scans with standard scan bodies versus scannable healing abutments on scanning accuracy, scanning time, and number of photograms: a comparative clinical study","author":"G\u00f3mez-Polo","year":"2025","journal-title":"J. Proshtet. Dent"},{"key":"10.1016\/j.jdent.2025.106180_bib0040","article-title":"Enhancing implant prosthodontics: in vitro accuracy of coded healing abutments on the edentulous lower jaw, clin","volume":"27","author":"V\u00e1nkos","year":"2025","journal-title":"Implant Dent. Rel. Res"},{"key":"10.1016\/j.jdent.2025.106180_bib0041","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.prosdent.2022.01.018","article-title":"Effect of scan pattern on the scan accuracy of a combined healing abutment scan body system","volume":"131","author":"Yilmaz","year":"2024","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0042","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.prosdent.2019.06.012","article-title":"Effect of coded healing abutment height and position on the trueness of digital intraoral implant scans","volume":"123","author":"Batak","year":"2020","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0043","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1111\/jopr.13749","article-title":"Intraoral digital implant scans: parameters to improve accuracy","volume":"32","author":"Revilla-Le\u00f3n","year":"2023","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2025.106180_bib0044","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104716","article-title":"Trueness and precision of combined healing abutment scan body system scans at different sites of maxilla after multiple repositioning of the scan body","volume":"139","author":"Donmez","year":"2023","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0045","doi-asserted-by":"crossref","first-page":"29","DOI":"10.14368\/jdras.2020.36.1.29","article-title":"Comparison of the accuracy of implant digital impression coping","volume":"36","author":"Ahn","year":"2020","journal-title":"J. Dent. Rehabil. Appl. Sci."},{"key":"10.1016\/j.jdent.2025.106180_bib0046","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2022.104391","article-title":"In vitro comparison of five desktop scanners and an industrial scanner in the evaluation of an intraoral scanner accuracy","volume":"129","author":"Borbola","year":"2023","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0047","doi-asserted-by":"crossref","first-page":"927","DOI":"10.11607\/jomi.3433","article-title":"Three-dimensional accuracy of a digitally coded healing abutment implant impression system","volume":"29","author":"Ng","year":"2014","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"10.1016\/j.jdent.2025.106180_bib0048","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1016\/j.prosdent.2023.01.029","article-title":"Scan accuracy and time efficiency of different implant-supported fixed partial denture situations depending on the intraoral scanner and scanned area: an in vitro study","volume":"131","author":"Donmez","year":"2024","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0049","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1111\/clr.12841","article-title":"Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis","volume":"28","author":"Raico Gallardo","year":"2017","journal-title":"Clin. Oral Impl. Res."},{"key":"10.1016\/j.jdent.2025.106180_bib0050","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1111\/jcpe.13160","article-title":"The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery","volume":"46","author":"Smitkarn","year":"2019","journal-title":"J. Clin. Periodontol."},{"key":"10.1016\/j.jdent.2025.106180_bib0051","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1111\/clr.12638","article-title":"Computer-supported implant planning and guided surgery: a narrative review","volume":"26","author":"Vercruyssen","year":"2015","journal-title":"Clin. Oral Impl. Res."},{"key":"10.1016\/j.jdent.2025.106180_bib0052","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104641","article-title":"Accuracy of single-implant digital impression with various scanbody exposure levels at anterior and posterior regions","volume":"138","author":"Wu","year":"2023","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0053","doi-asserted-by":"crossref","first-page":"201","DOI":"10.17219\/dmp\/127963","article-title":"Retention of a telescopic overdenture on customized abutments after the simulation of 1 year in function","volume":"58","author":"Ramadan","year":"2021","journal-title":"Dent. Med. Probl."},{"key":"10.1016\/j.jdent.2025.106180_bib0054","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1016\/j.prosdent.2023.05.022","article-title":"Evaluation of prosthetic screw loosening in all-on-four implant-supported restorations with two different connection systems","volume":"133","author":"Bekhit","year":"2025","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2025.106180_bib0055","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1111\/clr.14025","article-title":"Influence of the abutment height on marginal bone level changes around two-piece dental implants: meta-analysis and trial sequential analysis of randomized clinical trials","volume":"34","author":"Mu\u00f1oz","year":"2023","journal-title":"Clin. Oral Impl. Res."}],"container-title":["Journal of Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300571225006268?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300571225006268?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T05:24:30Z","timestamp":1763702670000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0300571225006268"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":55,"alternative-id":["S0300571225006268"],"URL":"https:\/\/doi.org\/10.1016\/j.jdent.2025.106180","relation":{},"ISSN":["0300-5712"],"issn-type":[{"value":"0300-5712","type":"print"}],"subject":[],"published":{"date-parts":[[2025,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Influence of three coded healing abutment design on intraoral scan accuracy: a comparative in vitro study","name":"articletitle","label":"Article Title"},{"value":"Journal of Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jdent.2025.106180","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"106180"}}