{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T18:50:31Z","timestamp":1791658231894,"version":"4.3.4"},"reference-count":53,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:00:00Z","timestamp":1781568000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Dentistry"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.jdent.2026.106837","type":"journal-article","created":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T16:27:32Z","timestamp":1781713652000},"page":"106837","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Three-year clinical outcomes of additively manufactured hybrid composite implant-supported restorations fabricated through tilting stereolithography: a retrospective clinical study"],"prefix":"10.1016","volume":"173","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5488-4268","authenticated-orcid":false,"given":"Francesco Guido","family":"Mangano","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlo","family":"Mangano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henriette","family":"Lerner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marina","family":"Loktionova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olesya","family":"Dudnik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olga","family":"Malanova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alina","family":"Elovskaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Maltseva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrey","family":"Dybov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jdent.2026.106837_bib0001","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103693","article-title":"Digital dentistry","volume":"109","author":"Mangano","year":"2021","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0002","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1111\/prd.12164","article-title":"Digital technology in fixed implant prosthodontics","volume":"73","author":"Joda","year":"2017","journal-title":"Periodontol. 2000"},{"key":"10.1016\/j.jdent.2026.106837_bib0003","doi-asserted-by":"crossref","DOI":"10.1016\/j.identj.2025.109296","article-title":"Digital Dentistry in Clinical practice: a scoping review of current capabilities and future directions","volume":"76","author":"Lam","year":"2026","journal-title":"Int. Dent. J."},{"key":"10.1016\/j.jdent.2026.106837_bib0004","doi-asserted-by":"crossref","first-page":"286","DOI":"10.11607\/jomi.10127","article-title":"Comparison of treatment time for single-implant crowns between digital and conventional workflows for posterior implant restorations: a randomized controlled trial","volume":"39","author":"Jarangkul","year":"2024","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"10.1016\/j.jdent.2026.106837_bib0005","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1111\/clr.14151","article-title":"Clinical evaluation and quantitative occlusal change analysis of posterior implant-supported all-ceramic crowns: a 3-year randomized controlled clinical trial","volume":"34","author":"Zhang","year":"2023","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2026.106837_bib0006","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103875","article-title":"Patient-reported outcome measures (PROMs) comparing digital and conventional workflows for treatment with posterior single-unit implant restorations: a randomized controlled trial","volume":"117","author":"Kunavisarut","year":"2022","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0007","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1111\/clr.13447","article-title":"Time efficiency and quality of outcomes in a model-free digital workflow using digital impression immediately after implant placement: a double-blind self-controlled clinical trial","volume":"30","author":"Pan","year":"2019","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2026.106837_bib0008","first-page":"1","article-title":"Digital versus Analog procedures for the prosthetic restoration of single implants: a randomized controlled trial with 1 year of follow-up","volume":"2018","author":"Mangano","year":"2018","journal-title":"Biomed. Res. Int."},{"key":"10.1016\/j.jdent.2026.106837_bib0009","doi-asserted-by":"crossref","first-page":"733","DOI":"10.11607\/ijp.7074","article-title":"A Randomized Clinical trial comparing the clinical fit of CAD\/CAM monolithic zirconia fixed dental prostheses (FDP) on ti-base abutments based on digital or conventional impression techniques. One year follow-up","volume":"34","author":"Derksen","year":"2021","journal-title":"Int. J. Prosthodont."},{"key":"10.1016\/j.jdent.2026.106837_bib0010","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105465","article-title":"A novel coded healing abutment for a simplified digital workflow: a retrospective clinical study on 103 patients with a one year follow-up","volume":"152","author":"Mouhyi","year":"2025","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0011","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1016\/j.prosdent.2022.11.013","article-title":"Survival and prosthetic complications of monolithic ceramic implant-supported single crowns and fixed partial dentures: a systematic review with meta-analysis","volume":"132","author":"Lemos","year":"2024","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0012","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1111\/jerd.13188","article-title":"Implant-supported single all-ceramic crowns made from prefabricated (stock) or individualized CAD\/CAM zirconia abutments: a 5 year randomized clinical trial","volume":"36","author":"Wittneben","year":"2024","journal-title":"J. Esthet. Restor. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0013","article-title":"Qualitative aspects and minimum requirements of milling machines in digital dentistry: a narrative review","volume":"1","author":"Ruggiero","year":"2025","journal-title":"Digital Dent J"},{"key":"10.1016\/j.jdent.2026.106837_bib0014","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1111\/jopr.13922","article-title":"Zirconia full-arch implant prostheses: survival, complications, and prosthetic space dimensions with 115 edentulous jaws","volume":"34","author":"Papaspyridakos","year":"2025","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2026.106837_bib0015","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1111\/cid.12885","article-title":"Clinical and laboratory passive fit assessment of implant-supported zirconia restorations fabricated using conventional and digital workflow","volume":"22","author":"Rutkunas","year":"2020","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"10.1016\/j.jdent.2026.106837_bib0016","doi-asserted-by":"crossref","DOI":"10.1155\/2016\/9840594","article-title":"Digitally oriented Materials\": focus on lithium disilicate ceramics","volume":"2016","author":"Zarone","year":"2016","journal-title":"Int. J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0017","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2026.106577","article-title":"Clinical performance of digitally planned lithium disilicate restorations for peg-shaped maxillary lateral incisors: a 5-year retrospective study","volume":"167","author":"Mangano","year":"2026","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0018","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105350","article-title":"Clinical outcome of monolithic zirconia on bonded or mechanically retained prefabricated titanium-base: a 4-year retrospective study","volume":"150","author":"Fiore","year":"2024","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0019","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1186\/s12903-020-1062-4","article-title":"Artificial intelligence in fixed implant prosthodontics: a retrospective study of 106 implant-supported monolithic zirconia crowns inserted in the posterior jaws of 90 patients","volume":"20","author":"Lerner","year":"2020","journal-title":"BMC. Oral Health"},{"key":"10.1016\/j.jdent.2026.106837_bib0020","doi-asserted-by":"crossref","first-page":"2465","DOI":"10.1007\/s00784-023-04983-7","article-title":"Three-dimensional (3D) printing in dental practice: applications, areas of interest, and level of evidence","volume":"27","author":"Balhaddad","year":"2023","journal-title":"Clin. Oral Investig."},{"issue":"S1","key":"10.1016\/j.jdent.2026.106837_bib0021","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/jopr.13477","article-title":"Additive manufacturing technologies: current status and future perspectives","volume":"31","author":"Alammar","year":"2022","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2026.106837_bib0022","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.dental.2023.12.004","article-title":"3D-printed and conventional provisional single crown fabrication on anterior implants: a randomized clinical trial","volume":"40","author":"de Souza","year":"2024","journal-title":"Dent. Mater."},{"key":"10.1016\/j.jdent.2026.106837_bib0023","article-title":"Four-piece CAD-CAM surgical guide for computer-guided surgery of immediate complete denture and implant-retained overdenture","volume":"2","author":"Yongyosrungrueng","year":"2025","journal-title":"Digital Dent J"},{"key":"10.1016\/j.jdent.2026.106837_bib0024","article-title":"Influence of temperature on the dimensional stability of DLP- and FDM-printed dental casts with different base designs","volume":"2","author":"Khaw","year":"2025","journal-title":"Digital Dent J"},{"key":"10.1016\/j.jdent.2026.106837_bib0025","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103630","article-title":"3D printing parameters, supporting structures, slicing, and post-processing procedures of vat- polymerization additive manufacturing technologies: a narrative review","volume":"109","author":"Piedra-Cascon","year":"2021","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0026","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103792","article-title":"Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: an in vitro study","volume":"113","author":"Lerner","year":"2021","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0027","doi-asserted-by":"crossref","first-page":"1","DOI":"10.11607\/prd.7886","article-title":"3D-Printed zirconia and lithium disilicate in dentistry and their clinical applications","volume":"38","author":"Lin","year":"2025","journal-title":"Int. J. Prosthodont."},{"key":"10.1016\/j.jdent.2026.106837_bib0028","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2024.106601","article-title":"The physical-mechanical properties of 3D-printed versus conventional milled zirconia for dental clinical applications: a systematic review with meta-analysis","volume":"156","author":"Alghauli","year":"2024","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.jdent.2026.106837_bib0029","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103886","article-title":"Lithography-based Ceramic manufacturing (LCM) versus milled Zirconia blocks under uniaxial compressive loading: an in vitro comparative study","volume":"116","author":"Gatto","year":"2022","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0030","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.106174","article-title":"From blueprints to reality: a narrative review of evidence-based 3D printers in dentistry","volume":"164","author":"Shujaat","year":"2026","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0031","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105527","article-title":"Comparison of fit and trueness of single-unit and short-span fixed dental restorations fabricated by additive and subtractive manufacturing-A systematic review and meta-analysis","volume":"153","author":"N\u00e9meth","year":"2025","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0032","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.106315","article-title":"Influence of different post-washing parameters on the properties of additively-manufactured dental devices - A systematic review","volume":"165","author":"Wang","year":"2026","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0033","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.prosdent.2023.03.020","article-title":"Influence of print orientation on the intaglio surface accuracy (trueness and precision) of tilting stereolithography definitive resin-ceramic crowns","volume":"133","author":"Revilla-Leon","year":"2025","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0034","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105702","article-title":"Trueness of multichromatic versus monochromatic veneers printed using tilted stereolithography technology at different build angles? An in vitro study","volume":"156","author":"Alharbi","year":"2025","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0035","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105875","article-title":"Influence of preparation design and build orientation on the accuracy of ceramic-filled composite veneers printed using Tilted Stereolithography technology. An in vitro study","volume":"161","author":"Osman","year":"2025","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0036","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104792","article-title":"Trueness, precision, time-efficiency and cost analysis of chairside additive and subtractive versus lab-based workflows for manufacturing single crowns: an in vitro study","volume":"141","author":"Mangano","year":"2024","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0037","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105095","article-title":"3D-printed short-span hybrid composite implant-supported restorations fabricated through tilting stereolithography: a retrospective clinical study on 85 patients with 1 year of follow-up","volume":"147","author":"Mangano","year":"2024","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0038","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105999","article-title":"Additively manufactured hybrid composite implant-supported restorations: a retrospective clinical study of 145 patients with up to 2 years of follow-up","volume":"161","author":"Mangano","year":"2025","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0039","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s00784-026-06883-y","article-title":"Performance of posterior 3D printed resin-matrix ceramic crowns fabricated in a fully digital workflow: a two-year prospective clinical study","volume":"30","author":"Del Pi\u00f1al Pell\u00f3n","year":"2026","journal-title":"Clin. Oral Investig."},{"key":"10.1016\/j.jdent.2026.106837_bib0040","first-page":"1","article-title":"Additively manufactured definitive crown resins on premolar and molar teeth: 2-year results of a prospective clinical study","volume":"38","author":"Sonkaya","year":"2025","journal-title":"Int. J. Prosthodont."},{"key":"10.1016\/j.jdent.2026.106837_bib0041","doi-asserted-by":"crossref","DOI":"10.3389\/fdmed.2024.1390600","article-title":"3D-printed resin composite posterior fixed dental prosthesis: a prospective clinical trial up to 1 year","volume":"5","author":"Hobbi","year":"2024","journal-title":"Front. Dent. Med."},{"key":"10.1016\/j.jdent.2026.106837_bib0042","doi-asserted-by":"crossref","first-page":"26","DOI":"10.15171\/joddd.2018.005","article-title":"Immediate functional loading of single implants: a multicenter study with 4 years of follow-up","volume":"12","author":"Raes","year":"2018","journal-title":"J. Dent. Res. Dent. Clin. Dent. Prospects."},{"key":"10.1016\/j.jdent.2026.106837_bib0043","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1111\/clr.12923","article-title":"Short (6- mm) dental implants versus sinus floor elevation and placement of longer (\u226510- mm) dental implants: a randomized controlled trial with a 3-year follow-up","volume":"28","author":"Bechara","year":"2017","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2026.106837_bib0044","doi-asserted-by":"crossref","DOI":"10.1155\/2016\/9393219","article-title":"Soft tissue stability around single implants inserted to replace maxillary lateral incisors: a 3D evaluation","volume":"2016","author":"Mangano","year":"2016","journal-title":"Int. J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0045","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105317","article-title":"Guided versus freehand single implant placement: a 3-year parallel randomized clinical trial","volume":"149","author":"Lops","year":"2024","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0046","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1111\/clr.12439","article-title":"Fixed restorations supported by Morse-taper connection implants: a retrospective clinical study with 10-20 years of follow-up","volume":"26","author":"Mangano","year":"2015","journal-title":"Clin. Oral Implants Res."},{"key":"10.1016\/j.jdent.2026.106837_bib0047","doi-asserted-by":"crossref","first-page":"448","DOI":"10.11607\/jomi.3327","article-title":"Clinical outcome of narrow-diameter (3.3-mm) locking-taper implants: a prospective study with 1 to 10 years of follow-up","volume":"29","author":"Mangano","year":"2014","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"10.1016\/j.jdent.2026.106837_bib0048","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2026.106531","article-title":"3D-printed resins intended for long-term restoration vs. conventionally used materials: a systematic review and network meta-analysis of in vitro studies","volume":"167","author":"Lalvay","year":"2026","journal-title":"J. Dent."},{"issue":"0","key":"10.1016\/j.jdent.2026.106837_bib0049","doi-asserted-by":"crossref","first-page":"1","DOI":"10.11607\/ijp.9569","article-title":"Comparison of implant-supported permanent crowns produced w\u0131th different 3D printed resins in terms of product\u0131on accuracy, marginal fit and internal fit: a comparative in vitro study","volume":"0","author":"Herguner","year":"2026","journal-title":"Int. J. Prosthodont."},{"issue":"0","key":"10.1016\/j.jdent.2026.106837_bib0050","doi-asserted-by":"crossref","first-page":"1","DOI":"10.11607\/ijp.9565","article-title":"Evaluation of mechanical and physical properties of implant- supported crowns produced from different 3D-printed permanent resin materials: an In vitro comparative study","volume":"0","author":"Cilesiz","year":"2026","journal-title":"Int. J. Prosthodont."},{"key":"10.1016\/j.jdent.2026.106837_bib0051","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1111\/jopr.70024","article-title":"Marginal and internal fit of permanent crowns produced by different three-dimensional printing systems: a micro-computed tomography and digital three-dimensional analysis","volume":"35","author":"Arslan","year":"2026","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2026.106837_bib0052","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1111\/jerd.13371","article-title":"Advances in dental restorations: a comprehensive review of machinable and 3D-printed ceramic-reinforced composites","volume":"37","author":"Duarte","year":"2025","journal-title":"J. Esthet. Restor. Dent."},{"key":"10.1016\/j.jdent.2026.106837_bib0053","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105887","article-title":"Assessing the performance of 3D-printed resin composite posterior fixed dental prostheses: a 3-year prospective clinical trial","volume":"160","author":"Hobbi","year":"2025","journal-title":"J. Dent."}],"container-title":["Journal of Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300571226005075?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300571226005075?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T18:45:56Z","timestamp":1791657956000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0300571226005075"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":53,"alternative-id":["S0300571226005075"],"URL":"https:\/\/doi.org\/10.1016\/j.jdent.2026.106837","relation":{},"ISSN":["0300-5712"],"issn-type":[{"value":"0300-5712","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Three-year clinical outcomes of additively manufactured hybrid composite implant-supported restorations fabricated through tilting stereolithography: a retrospective clinical study","name":"articletitle","label":"Article Title"},{"value":"Journal of Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jdent.2026.106837","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"106837"}}