{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T04:38:36Z","timestamp":1792643916842,"version":"4.5.0"},"reference-count":25,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T00:00:00Z","timestamp":1787788800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Dentistry"],"published-print":{"date-parts":[[2027,1]]},"DOI":"10.1016\/j.jdent.2026.107004","type":"journal-article","created":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T15:30:44Z","timestamp":1788190244000},"page":"107004","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["The effect of build angle and intraarch connector design on the accuracy and fit of additively manufactured complete-arch implant-supported interim fixed prostheses"],"prefix":"10.1016","volume":"176","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-8651-6976","authenticated-orcid":false,"given":"Steven","family":"Sonderegger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro Molinero","family":"Mourelle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"Aeschbacher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Burak","family":"Yilmaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6974-1980","authenticated-orcid":false,"given":"Cecilia Santos","family":"Galvao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00fclce","family":"\u00c7akmak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jdent.2026.107004_bib0001","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.prosdent.2017.07.001","article-title":"Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques","volume":"119","author":"Papadiochou","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0002","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103777","article-title":"CAD-CAM removable complete dentures: a systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes","volume":"113","author":"Srinivasan","year":"2021","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0003","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1111\/clr.13801","article-title":"Production time, effectiveness and costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses: a systematic review","volume":"32","author":"M\u00fchlemann","year":"2021","journal-title":"Clin. Oral Implant. Res."},{"key":"10.1016\/j.jdent.2026.107004_bib0004","doi-asserted-by":"crossref","first-page":"129","DOI":"10.5005\/jp-journals-10024-3472","article-title":"Reasons for failure of CAD\/CAM restorations in clinical studies: a systematic review and meta-analysis","volume":"24","author":"Lampl","year":"2023","journal-title":"J. Contemp. Dent. Pract."},{"key":"10.1016\/j.jdent.2026.107004_bib0005","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104697","article-title":"Comparison of intraoral and laboratory scanners to an industrial-grade scanner while analyzing the fabrication trueness of polymer and titanium complete-arch implant-supported frameworks","volume":"138","author":"Yilmaz","year":"2023","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0006","doi-asserted-by":"crossref","first-page":"2691","DOI":"10.3390\/polym14132691","article-title":"Physical and mechanical properties of 3D-printed provisional crowns and fixed dental prosthesis resins compared to CAD\/CAM milled and conventional provisional resins: a systematic review and meta-analysis","volume":"14","author":"Jain","year":"2022","journal-title":"Polymers"},{"key":"10.1016\/j.jdent.2026.107004_bib0007","doi-asserted-by":"crossref","first-page":"S159","DOI":"10.11607\/ijp.8832","article-title":"3D printing of complete dentures: a narrative review","volume":"37","author":"Goodacre","year":"2024","journal-title":"Int. J. Prosthodont."},{"key":"10.1016\/j.jdent.2026.107004_bib0008","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/j.prosdent.2021.05.010","article-title":"Accuracy of marginal fit of an implant-supported framework fabricated by 3D printing versus subtractive manufacturing technique: a systematic review and meta-analysis","volume":"129","author":"Thakur","year":"2023","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0009","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104548","article-title":"Effect of number of supports and build angle on the fabrication and internal fit accuracy of additively manufactured definitive resin-ceramic hybrid crowns","volume":"134","author":"\u00c7akmak","year":"2023","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0010","doi-asserted-by":"crossref","first-page":"261","DOI":"10.2334\/josnusd.23-0115","article-title":"Effect of build orientation on the trueness of occlusal splints fabricated by three-dimensional printing","volume":"65","author":"Cameron","year":"2023","journal-title":"J. Oral Sci."},{"key":"10.1016\/j.jdent.2026.107004_bib0011","doi-asserted-by":"crossref","first-page":"150","DOI":"10.4047\/jap.2022.14.3.150","article-title":"Trueness of 3D printed partial denture frameworks: build orientations and support structure density parameters","volume":"14","author":"Hussein","year":"2022","journal-title":"J. Adv. Prosthodont."},{"key":"10.1016\/j.jdent.2026.107004_bib0012","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.prosdent.2017.11.021","article-title":"Marginal discrepancy of CAD-CAM complete-arch fixed implant-supported frameworks","volume":"120","author":"Yilmaz","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0013","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.106234","article-title":"Printing accuracy and post-mounting dimensional stability of 3D-printed hollow dental models with varying shell thicknesses and cross-arch bars","volume":"164","author":"Wan","year":"2026","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0014","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1111\/cid.13362","article-title":"Trueness and fit of complete-arch implant-supported frameworks in new-generation additively and subtractively manufactured polymers: an in-vitro study","volume":"26","author":"Yilmaz","year":"2024","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"10.1016\/j.jdent.2026.107004_bib0015","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103784","article-title":"Trueness and marginal fit of implant-supported complete-arch fixed prosthesis frameworks made of high-performance polymers and titanium: an explorative in-vitro study","volume":"113","author":"Abou-Ayash","year":"2021","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0016","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.prosdent.2017.04.023","article-title":"In vitro fit of CAD-CAM complete arch screw-retained titanium and zirconia implant prostheses fabricated on 4 implants","volume":"119","author":"Al-Meraikhi","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0017","first-page":"1","article-title":"Effect of build orientation on the fabrication trueness of additively manufactured implant-supported complete arch interim fixed prostheses","author":"Nejat","year":"2024","journal-title":"J. Prosthodont."},{"issue":"4","key":"10.1016\/j.jdent.2026.107004_bib0018","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1111\/jopr.13830","article-title":"Implementation of triple-scan protocol to evaluate the fit of complete-arch implant-supported fixed prostheses","volume":"34","author":"Borga Donmez","year":"2025","journal-title":"J. Prosthodont."},{"key":"10.1016\/j.jdent.2026.107004_bib0019","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1111\/j.1600-0501.2011.02219.x","article-title":"Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study","volume":"23","author":"Papaspyridakos","year":"2012","journal-title":"Clin. Oral Implant. Res."},{"key":"10.1016\/j.jdent.2026.107004_bib0020","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.prosdent.2022.09.010","article-title":"Magnitude of misfit threshold in implant-supported restorations: a systematic review","volume":"132","author":"Abdelrehim","year":"2024","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0021","doi-asserted-by":"crossref","first-page":"783.e1","DOI":"10.1016\/j.prosdent.2025.04.042","article-title":"Additive manufacturing of CAD-CAM complete arch fixed implant restorations supported by six implants: prosthetic screw stability and marginal precision under masticatory simulation","volume":"134","author":"Vel\u00f4so","year":"2025","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0022","doi-asserted-by":"crossref","first-page":"191","DOI":"10.4103\/jips.jips_40_25","article-title":"Marginal gap of three-dimensional printed full-arch frameworks supported by all-on-four and all-on-six implant designs","volume":"25","author":"Silva","year":"2025","journal-title":"J. Indian Prosthodont. Soc."},{"key":"10.1016\/j.jdent.2026.107004_bib0023","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2022.104154","article-title":"Comparison of measured deviations in digital implant scans depending on software and operator","volume":"122","author":"Cakmak","year":"2022","journal-title":"J. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0024","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1016\/j.prosdent.2016.03.012","article-title":"In vitro assessment of the marginal and internal fits of interim implant restorations fabricated with different methods","volume":"116","author":"Park","year":"2016","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107004_bib0025","doi-asserted-by":"crossref","first-page":"753.e1","DOI":"10.1016\/j.prosdent.2025.11.019","article-title":"Precision of measurement methods for assessing the fit of screw-retained implant-supported fixed partial dentures: a systematic review of in vitro studies","volume":"135","author":"He","year":"2026","journal-title":"J. Prosthet. Dent."}],"updated-by":[{"DOI":"10.1016\/j.jdent.2026.107116","type":"erratum","label":"Erratum","source":"publisher","updated":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T00:00:00Z","timestamp":1792627200000}}],"container-title":["Journal of Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300571226006743?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300571226006743?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T13:24:09Z","timestamp":1792243449000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0300571226006743"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2027,1]]},"references-count":25,"alternative-id":["S0300571226006743"],"URL":"https:\/\/doi.org\/10.1016\/j.jdent.2026.107004","relation":{},"ISSN":["0300-5712"],"issn-type":[{"value":"0300-5712","type":"print"}],"subject":[],"published":{"date-parts":[[2027,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The effect of build angle and intraarch connector design on the accuracy and fit of additively manufactured complete-arch implant-supported interim fixed prostheses","name":"articletitle","label":"Article Title"},{"value":"Journal of Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jdent.2026.107004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"107004"}}