{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T03:52:47Z","timestamp":1791085967602,"version":"4.1.0"},"reference-count":37,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100023915","name":"Chulalongkorn University Faculty of Dentistry","doi-asserted-by":"publisher","award":["DRF 70_004"],"award-info":[{"award-number":["DRF 70_004"]}],"id":[{"id":"10.13039\/501100023915","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Dentistry"],"published-print":{"date-parts":[[2027,1]]},"DOI":"10.1016\/j.jdent.2026.107060","type":"journal-article","created":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T00:10:28Z","timestamp":1790035828000},"page":"107060","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Implant\u2013soft tissue registration trueness across alignment protocols in intraoral photogrammetry"],"prefix":"10.1016","volume":"176","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3393-5094","authenticated-orcid":false,"given":"Siraphob","family":"Techapiroontong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-6979-6149","authenticated-orcid":false,"given":"Veerit","family":"Tanvarasethee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8109-3338","authenticated-orcid":false,"given":"Wacharasak","family":"Tumrasvin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2631-7722","authenticated-orcid":false,"given":"Jae-Hyun","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9347-1132","authenticated-orcid":false,"given":"Nareudee","family":"Limpuangthip","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"9","key":"10.1016\/j.jdent.2026.107060_bib0001","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000018950","article-title":"Eleven-year follow-up of reconstruction with autogenous iliac bone graft and implant-supported fixed complete denture for severe maxillary atrophy: a case report","volume":"99","author":"Lee","year":"2020","journal-title":"Medicine"},{"issue":"3","key":"10.1016\/j.jdent.2026.107060_bib0002","article-title":"The all-on-four treatment concept: systematic review","volume":"9","author":"Soto-Penaloza","year":"2017","journal-title":"J. Clin. Exp. Dent."},{"issue":"6","key":"10.1016\/j.jdent.2026.107060_bib0003","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1016\/j.prosdent.2021.12.020","article-title":"Implant survival rate and marginal bone loss with the all-on-4 immediate-loading strategy: a clinical retrospective study with 1 to 4 years of follow-up","volume":"130","author":"Yang","year":"2023","journal-title":"J. Prosthet. Dent."},{"issue":"10","key":"10.1016\/j.jdent.2026.107060_bib0004","doi-asserted-by":"crossref","first-page":"3452","DOI":"10.3390\/jcm12103452","article-title":"Evaluation of prosthetic marginal fit and implant survival rates for conventional and digital workflows in full-arch immediate loading rehabilitations: a retrospective clinical study","volume":"12","author":"De Angelis","year":"2023","journal-title":"J. Clin. Med."},{"issue":"4","key":"10.1016\/j.jdent.2026.107060_bib0005","doi-asserted-by":"crossref","first-page":"212","DOI":"10.4047\/jap.2022.14.4.212","article-title":"Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction","volume":"14","author":"Carneiro Pereira","year":"2022","journal-title":"J. Adv. Prosthodont."},{"issue":"5","key":"10.1016\/j.jdent.2026.107060_bib0006","doi-asserted-by":"crossref","first-page":"997","DOI":"10.11607\/jomi.9441","article-title":"Accuracy of impression techniques for dental implants placed in five different orientations","volume":"37","author":"Kim","year":"2022","journal-title":"Int. J. Oral Maxillofac. Implant.s"},{"issue":"1","key":"10.1016\/j.jdent.2026.107060_bib0007","doi-asserted-by":"crossref","first-page":"52","DOI":"10.4012\/dmj.2019-224","article-title":"Progress in digital dentistry: the practical use of intraoral scanners","volume":"39","author":"Suese","year":"2020","journal-title":"Dent. Mater. J."},{"issue":"8","key":"10.1016\/j.jdent.2026.107060_bib0008","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.3390\/jcm8081187","article-title":"Repeatability of intraoral scanners for complete arch scan of partially edentulous dentitions: an in vitro study","volume":"8","author":"Lee","year":"2019","journal-title":"J. Clin. Med."},{"issue":"5","key":"10.1016\/j.jdent.2026.107060_bib0009","doi-asserted-by":"crossref","first-page":"898.e1","DOI":"10.1016\/j.prosdent.2024.06.010","article-title":"Enhancing scanning accuracy of digital implant scans: a systematic review on application methods of scan bodies","volume":"132","author":"Wan","year":"2024","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107060_bib0010","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.104854","article-title":"Impact of scanning distance on the accuracy of a photogrammetry system","volume":"142","author":"Revilla-Le\u00f3n","year":"2024","journal-title":"J. Dent."},{"issue":"1","key":"10.1016\/j.jdent.2026.107060_bib0011","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.prosdent.2024.01.008","article-title":"Influence of implant reference on the scanning accuracy of complete arch implant scans captured by using a photogrammetry system","volume":"133","author":"Revilla-Le\u00f3n","year":"2025","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107060_bib0012","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1016\/j.prosdent.2025.07.027","article-title":"Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems and a noncalibrated splinting technique: a clinical study","volume":"135","author":"Revilla-Le\u00f3n","year":"2026","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107060_bib0013","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105654","article-title":"Accuracy of intraoral photogrammetry versus direct digital implant impressions in the fully edentulous lower jaw: an in vitro study","volume":"156","author":"Brako\u010d","year":"2025","journal-title":"J. Dent."},{"issue":"8","key":"10.1016\/j.jdent.2026.107060_bib0014","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1111\/clr.14445","article-title":"Accuracy of a novel intraoral photogrammetry technique for complete-arch implant impressions: an in vitro study","volume":"36","author":"Fu","year":"2025","journal-title":"Clin. Oral Implant. Res."},{"key":"10.1016\/j.jdent.2026.107060_bib0015","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.106269","article-title":"Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro study","volume":"165","author":"Mangano","year":"2026","journal-title":"J. Dent."},{"issue":"3","key":"10.1016\/j.jdent.2026.107060_bib0016","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1016\/j.prosdent.2025.04.037","article-title":"Registration accuracy of soft tissue information scan captured using an intraoral scanner and implant position scan recorded using extraoral and intraoral photogrammetry systems","volume":"135","author":"Revilla-Le\u00f3n","year":"2026","journal-title":"J. Prosthet. Dent."},{"issue":"4","key":"10.1016\/j.jdent.2026.107060_bib0017","doi-asserted-by":"crossref","first-page":"1259.e1","DOI":"10.1016\/j.prosdent.2025.06.015","article-title":"Alignment accuracy of soft tissue and implant position scans captured by using four intraoral scanners and an intraoral photogrammetry system with and without coded healing abutments","volume":"134","author":"Revilla-Le\u00f3n","year":"2025","journal-title":"J. Prosthet. Dent."},{"issue":"1","key":"10.1016\/j.jdent.2026.107060_bib0018","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1111\/j.1532-849X.1999.tb00005.x","article-title":"Classification system for complete edentulism. The American college of prosthodontics","volume":"8","author":"McGarry","year":"1999","journal-title":"J. Prosthodont."},{"issue":"2","key":"10.1016\/j.jdent.2026.107060_bib0019","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.prosdent.2025.03.041","article-title":"Accuracy of intraoral photogrammetry in complete arch digital implant scanning: an in vivo prospective comparative study","volume":"135","author":"Eldabe","year":"2026","journal-title":"J. Prosthet. Dent."},{"issue":"4","key":"10.1016\/j.jdent.2026.107060_bib0020","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1016\/j.prosdent.2025.06.036","article-title":"Implant scanning workflow for fabricating implant-supported prostheses by using an intraoral photogrammetry system to capture implant position and automatically align soft tissue scan","volume":"135","author":"G\u00f3mez-Polo","year":"2026","journal-title":"J. Prosthet. Dent."},{"key":"10.1016\/j.jdent.2026.107060_bib0021","unstructured":"Coded Scan Body Scanning [Internet]. Hangzhou (China): Shining 3D; 2024. Available from: https:\/\/docs.shining3d.com\/intraoralscan\/3.5.2\/elite\/en-us\/scan-scanbody\/. Accessed 8 August 2026."},{"key":"10.1016\/j.jdent.2026.107060_bib0022","unstructured":"International Organization for Standardization. ISO 5725\u20131:1994. Accuracy (trueness and precision) of Measurement Methods and Results - Part 1: General principles and Definitions. Available from: https:\/\/www.iso.org\/obp\/ui\/#iso:std:iso:5725:-1:ed-1:v1:en."},{"key":"10.1016\/j.jdent.2026.107060_bib0023","unstructured":"International Organization for Standardization. ISO 20896\u20131:2019. Dentistry \u2014 Digital impression Devices \u2014 Part 1: Methods for Assessing Accuracy: Available from: https:\/\/www.iso.org\/standard\/69402.html."},{"issue":"5","key":"10.1016\/j.jdent.2026.107060_bib0024","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1111\/clr.14252","article-title":"Accuracy of edentulous full-arch implant impression: an in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry","volume":"35","author":"Cheng","year":"2024","journal-title":"Clin. Oral Implants Res."},{"issue":"6","key":"10.1016\/j.jdent.2026.107060_bib0025","doi-asserted-by":"crossref","first-page":"319","DOI":"10.4047\/jap.2024.16.6.319","article-title":"Effect of scan path on accuracy of complete arch intraoral scan","volume":"16","author":"Choi","year":"2024","journal-title":"J. Adv. Prosthodont."},{"issue":"S2","key":"10.1016\/j.jdent.2026.107060_bib0026","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1111\/jopr.13749","article-title":"Intraoral digital implant scans: parameters to improve accuracy","volume":"32","author":"Revilla-Le\u00f3n","year":"2023","journal-title":"J. Prosthodont."},{"issue":"1","key":"10.1016\/j.jdent.2026.107060_bib0027","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.prosdent.2023.09.029","article-title":"Assessment of distortion of intraoral scans of edentulous mandibular arch made with a 2-step scanning strategy: a clinical study","volume":"134","author":"Russo","year":"2025","journal-title":"J. Prosthet. Dent."},{"issue":"4","key":"10.1016\/j.jdent.2026.107060_bib0028","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1111\/cid.12919","article-title":"The effect of scanner type and scan body position on the accuracy of complete-arch digital implant scans","volume":"22","author":"\u00c7akmak","year":"2020","journal-title":"Clin. Implant Dent. Relat. Res."},{"issue":"1","key":"10.1016\/j.jdent.2026.107060_bib0029","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.prosdent.2021.05.019","article-title":"Trueness and precision of complete-arch photogrammetry implant scanning assessed with a coordinate-measuring machine","volume":"129","author":"Revilla-Le\u00f3n","year":"2023","journal-title":"J. Prosthet. Dent."},{"issue":"1","key":"10.1016\/j.jdent.2026.107060_bib0030","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1186\/s12903-025-06029-8","article-title":"Comparison of photogrammetric imaging, intraoral scanning and conventional impression accuracy of full-arch dental implant rehabilitation: an in vitro study","volume":"25","author":"Abuduwaili","year":"2025","journal-title":"BMC. Oral. Health."},{"key":"10.1016\/j.jdent.2026.107060_bib0031","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2022.104266","article-title":"Comparison of different artificial landmarks and scanning patterns on the complete-arch implant intraoral digital scans","volume":"125","author":"Kanjanasavitree","year":"2022","journal-title":"J. Dent."},{"issue":"1","key":"10.1016\/j.jdent.2026.107060_bib0032","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.jds.2023.09.009","article-title":"Accuracy comparison of scan segmental sequential ranges with two intraoral scanners for maxilla and mandible","volume":"19","author":"Liu","year":"2024","journal-title":"J. Dent. Sci."},{"issue":"1","key":"10.1016\/j.jdent.2026.107060_bib0033","doi-asserted-by":"crossref","first-page":"1428","DOI":"10.1186\/s12903-024-05199-1","article-title":"Effect of saliva on accuracy of digital dental implant transfer using two different materials of intraoral scan bodies with different exposed lengths","volume":"24","author":"Tawfik","year":"2024","journal-title":"BMC. Oral. Health."},{"key":"10.1016\/j.jdent.2026.107060_bib0034","series-title":"Cap Scan Body [Internet]","year":"2025"},{"issue":"3","key":"10.1016\/j.jdent.2026.107060_bib0035","doi-asserted-by":"crossref","first-page":"279","DOI":"10.4103\/jips.jips_108_22","article-title":"Accuracy between intraoral and extraoral scanning: three-dimensional deviation and effect of distance between implants from two scanning methods","volume":"22","author":"Pereira","year":"2022","journal-title":"J. Indian Prosthodont. Soc."},{"issue":"1","key":"10.1016\/j.jdent.2026.107060_bib0036","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.prosdent.2016.01.006","article-title":"Method to improve passive fit of frameworks on implant-supported prostheses: an in vitro study","volume":"116","author":"Manzella","year":"2016","journal-title":"J. Prosthet. Dent."},{"issue":"3","key":"10.1016\/j.jdent.2026.107060_bib0037","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.prosdent.2022.09.010","article-title":"Magnitude of misfit threshold in implant-supported restorations: a systematic review","volume":"132","author":"Abdelrehim","year":"2024","journal-title":"J. Prosthet. Dent."}],"container-title":["Journal of Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300571226007293?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300571226007293?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T03:10:30Z","timestamp":1791083430000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0300571226007293"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2027,1]]},"references-count":37,"alternative-id":["S0300571226007293"],"URL":"https:\/\/doi.org\/10.1016\/j.jdent.2026.107060","relation":{},"ISSN":["0300-5712"],"issn-type":[{"value":"0300-5712","type":"print"}],"subject":[],"published":{"date-parts":[[2027,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Implant\u2013soft tissue registration trueness across alignment protocols in intraoral photogrammetry","name":"articletitle","label":"Article Title"},{"value":"Journal of Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jdent.2026.107060","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"107060"}}