{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T21:53:39Z","timestamp":1791496419446,"version":"4.3.4"},"reference-count":36,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,7,6]],"date-time":"2024-07-06T00:00:00Z","timestamp":1720224000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100012544","name":"China Medical University","doi-asserted-by":"publisher","award":["CMU112-S-10"],"award-info":[{"award-number":["CMU112-S-10"]}],"id":[{"id":"10.13039\/501100012544","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Dental Sciences"],"published-print":{"date-parts":[[2024,10]]},"DOI":"10.1016\/j.jds.2024.07.005","type":"journal-article","created":{"date-parts":[[2024,7,12]],"date-time":"2024-07-12T21:36:39Z","timestamp":1720820199000},"page":"2007-2017","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"title":["Optimal positions of clear aligner attachments to achieve lower canine tipping and bodily movement using finite element analysis"],"prefix":"10.1016","volume":"19","author":[{"given":"Pin-Yu","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heng-Li","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian-Hong","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5533-2059","authenticated-orcid":false,"given":"Jui-Ting","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jds.2024.07.005_bib1","doi-asserted-by":"crossref","DOI":"10.1115\/1.4000154","article-title":"Load response of periodontal ligament: assessment of fluid flow, compressibility, and effect of pore pressure","volume":"132","author":"Bergomi","year":"2010","journal-title":"J Biomech Eng"},{"key":"10.1016\/j.jds.2024.07.005_bib2","doi-asserted-by":"crossref","DOI":"10.1115\/1.2900415","article-title":"A visco-hyperelastic-damage constitutive model for the analysis of the biomechanical response of the periodontal ligament","volume":"130","author":"Natali","year":"2008","journal-title":"J Biomech Eng"},{"key":"10.1016\/j.jds.2024.07.005_bib3","series-title":"Contemporary orthodontics","author":"Proffit","year":"2019"},{"key":"10.1016\/j.jds.2024.07.005_bib4","doi-asserted-by":"crossref","first-page":"563","DOI":"10.22974\/jkda.2016.54.7.008","article-title":"Clinical limitations and its solutions of the clear overlay appliance treatment","volume":"54","author":"Bae","year":"2016","journal-title":"J Korean Dent Assoc"},{"key":"10.1016\/j.jds.2024.07.005_bib5","doi-asserted-by":"crossref","first-page":"881","DOI":"10.2319\/061614-436.1","article-title":"Efficacy of clear aligners in controlling orthodontic tooth movement: a systematic review","volume":"85","author":"Rossini","year":"2015","journal-title":"Angle Orthod"},{"key":"10.1016\/j.jds.2024.07.005_bib6","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1053\/j.sodo.2016.10.005","article-title":"Improving the predictability of clear aligners","volume":"23","author":"Bowman","year":"2017","journal-title":"Semin Orthod"},{"key":"10.1016\/j.jds.2024.07.005_bib7","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1007\/s40846-022-00741-4","article-title":"The stress and deformation effect of novel rapid maxillary expanders by finite element analysis","volume":"42","author":"Lu","year":"2022","journal-title":"J Med Biol Eng"},{"key":"10.1016\/j.jds.2024.07.005_bib8","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.ajodo.2020.04.028","article-title":"Efficacy of invisalign attachments: a retrospective study","volume":"160","author":"Karras","year":"2021","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.jds.2024.07.005_bib9","doi-asserted-by":"crossref","first-page":"454","DOI":"10.2319\/050714-330.1","article-title":"Initial force systems during bodily tooth movement with plastic aligners and composite attachments: a three-dimensional finite element analysis","volume":"85","author":"Gomez","year":"2015","journal-title":"Angle Orthod"},{"key":"10.1016\/j.jds.2024.07.005_bib10","doi-asserted-by":"crossref","first-page":"e533","DOI":"10.3390\/ma15020533","article-title":"Effects of composite attachments on orthodontic clear aligners therapy: a systematic review","volume":"15","author":"Nucera","year":"2022","journal-title":"Materials"},{"key":"10.1016\/j.jds.2024.07.005_bib11","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1093\/ejo\/25.6.569","article-title":"Experimental and numerical determination of initial tooth mobility and material properties of the periodontal ligament in rat molar specimens","volume":"25","author":"Kawarizadeh","year":"2003","journal-title":"Eur J Orthod"},{"key":"10.1016\/j.jds.2024.07.005_bib12","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1007\/s00056-002-0067-8","article-title":"Determination of the elasticity parameters of the human periodontal ligament and the location of the center of resistance of single-rooted teeth a study of autopsy specimens and their conversion into finite element models","volume":"63","author":"Poppe","year":"2002","journal-title":"J Orofac Orthop"},{"key":"10.1016\/j.jds.2024.07.005_bib13","article-title":"Mandible integrity and material properties of the periodontal ligament during orthodontic tooth movement: a finite-element study","volume":"10","author":"Huang","year":"2020","journal-title":"Appl Sci"},{"key":"10.1016\/j.jds.2024.07.005_bib14","doi-asserted-by":"crossref","first-page":"5661","DOI":"10.1007\/s00784-021-03868-x","article-title":"Biomechanical analysis of occlusal modes on the periodontal ligament while orthodontic force applied","volume":"25","author":"Tsai","year":"2021","journal-title":"Clin Oral Invest"},{"key":"10.1016\/j.jds.2024.07.005_bib15","doi-asserted-by":"crossref","DOI":"10.3390\/ma14174926","article-title":"Efficient design of a clear aligner attachment to induce bodily tooth movement in orthodontic treatment using finite element analysis","volume":"14","author":"Hong","year":"2021","journal-title":"Materials"},{"key":"10.1016\/j.jds.2024.07.005_bib16","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.ajodo.2015.01.022","article-title":"Mandibular canine intrusion with the segmented arch technique: a finite element method study","volume":"147","author":"Caballero","year":"2015","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"10.1016\/j.jds.2024.07.005_bib17","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1016\/j.joms.2007.12.029","article-title":"Use of miniscrews and miniplates in orthodontics","volume":"66","author":"Leung","year":"2008","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.jds.2024.07.005_bib18","doi-asserted-by":"crossref","first-page":"247","DOI":"10.2319\/020719-86.1","article-title":"Clear aligner orthodontic therapy of rotated mandibular round-shaped teeth: a finite element study","volume":"90","author":"Cortona","year":"2020","journal-title":"Angle Orthod"},{"key":"10.1016\/j.jds.2024.07.005_bib19","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2020.104045","article-title":"Mechanical behaviour of 3D printed vs thermoformed clear dental aligner materials under non-linear compressive loading using FEM","volume":"112","author":"Jindal","year":"2020","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.jds.2024.07.005_bib20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2019\/1075097","article-title":"Effects of attachment of plastic aligner in closing of diastema of maxillary dentition by finite element method","volume":"2019","author":"Yokoi","year":"2019","journal-title":"J Healthc Eng"},{"key":"10.1016\/j.jds.2024.07.005_bib21","article-title":"Optimal position of attachment for removable thermoplastic aligner on the lower canine using finite element analysis","volume":"13","author":"Kim","year":"2020","journal-title":"Materials"},{"key":"10.1016\/j.jds.2024.07.005_bib22","doi-asserted-by":"crossref","first-page":"65","DOI":"10.4041\/kjod.2016.46.2.65","article-title":"Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor","volume":"46","author":"Li","year":"2016","journal-title":"Korean J Orthod"},{"key":"10.1016\/j.jds.2024.07.005_bib23","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0188707","article-title":"Inclusion of periodontal ligament fibres in mandibular finite element models leads to an increase in alveolar bone strains","volume":"12","author":"McCormack","year":"2017","journal-title":"PLoS One"},{"key":"10.1016\/j.jds.2024.07.005_bib24","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1093\/ejo\/cjv050","article-title":"Effect of material variation on the biomechanical behaviour of orthodontic fixed appliances: a finite element analysis","volume":"38","author":"Papageorgiou","year":"2016","journal-title":"Eur J Orthod"},{"key":"10.1016\/j.jds.2024.07.005_bib25","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1111\/clr.12059","article-title":"In\u00a0vitro bone strain analysis of implant following occlusal overload","volume":"25","author":"Kan","year":"2014","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.jds.2024.07.005_bib26","series-title":"Basic and applied bone biology","first-page":"203","article-title":"Mechanical adaptation","author":"Robling","year":"2019"},{"key":"10.1016\/j.jds.2024.07.005_bib27","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.odw.2017.09.001","article-title":"A method for evaluation of the effects of attachments in aligner-type orthodontic appliance: three-dimensional finite element analysis","volume":"76","author":"Goto","year":"2019","journal-title":"Orthod Waves"},{"key":"10.1016\/j.jds.2024.07.005_bib28","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1016\/j.jds.2021.01.011","article-title":"Effects of different aligner materials and attachments on orthodontic behavior","volume":"16","author":"Ho","year":"2021","journal-title":"J Dent Sci"},{"key":"10.1016\/j.jds.2024.07.005_bib29","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1016\/j.jds.2021.10.003","article-title":"N-acetylcysteine promotes cyclic mechanical stress-induced osteogenic differentiation of periodontal ligament stem cells by down-regulating Nrf2 expression","volume":"17","author":"Xi","year":"2022","journal-title":"J Dent Sci"},{"key":"10.1016\/j.jds.2024.07.005_bib30","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/S0889-5406(88)80010-6","article-title":"The effect of age on tooth movement and mineral density in the alveolar tissues of the rat","volume":"93","author":"Bridges","year":"1998","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"10.1016\/j.jds.2024.07.005_bib31","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/S8756-3282(99)00009-5","article-title":"Histomorphometric study of bone reactions during orthodontic tooth movement in rats","volume":"24","author":"Verna","year":"1999","journal-title":"Bone"},{"key":"10.1016\/j.jds.2024.07.005_bib32","first-page":"253","article-title":"The effect of protracted tetracycline treatment on bone growth and maturation","volume":"180","author":"Simmons","year":"1983","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.jds.2024.07.005_bib33","doi-asserted-by":"crossref","first-page":"342","DOI":"10.3181\/00379727-176-41880","article-title":"Mineralization in rat metaphyseal bone exhibits a circadian stage dependency","volume":"176","author":"Russell","year":"1984","journal-title":"Proc Soc Exp Biol Med"},{"key":"10.1016\/j.jds.2024.07.005_bib34","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1007\/s00784-010-0410-1","article-title":"Bone density changes around teeth during orthodontic treatment","volume":"15","author":"Hsu","year":"2011","journal-title":"Clin Oral Invest"},{"key":"10.1016\/j.jds.2024.07.005_bib35","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1007\/s00784-011-0552-9","article-title":"Effects of orthodontic tooth movement on alveolar bone density","volume":"16","author":"Chang","year":"2012","journal-title":"Clin Oral Invest"},{"key":"10.1016\/j.jds.2024.07.005_bib36","article-title":"Does orthodontic treatment affect the alveolar bone density?","volume":"95","author":"Yu","year":"2016","journal-title":"Medicine (Baltimore)"}],"container-title":["Journal of Dental Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1991790224002253?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1991790224002253?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T07:40:37Z","timestamp":1726126837000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1991790224002253"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":36,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,10]]}},"alternative-id":["S1991790224002253"],"URL":"https:\/\/doi.org\/10.1016\/j.jds.2024.07.005","relation":{},"ISSN":["1991-7902"],"issn-type":[{"value":"1991-7902","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Optimal positions of clear aligner attachments to achieve lower canine tipping and bodily movement using finite element analysis","name":"articletitle","label":"Article Title"},{"value":"Journal of Dental Sciences","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jds.2024.07.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}