{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T10:09:17Z","timestamp":1774951757183,"version":"3.50.1"},"reference-count":42,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T00:00:00Z","timestamp":1762819200000},"content-version":"vor","delay-in-days":10,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005790","name":"Thammasat University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005790","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Dental Sciences"],"published-print":{"date-parts":[[2025,11]]},"DOI":"10.1016\/j.jds.2025.11.009","type":"journal-article","created":{"date-parts":[[2025,11,26]],"date-time":"2025-11-26T20:27:56Z","timestamp":1764188876000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["The influence of the connector position placing, cement thickness and load direction on biomechanical performance of implant supported mesial cantilever: Finite element analysis"],"prefix":"10.1016","author":[{"given":"Bhrommin","family":"Toranathumkul","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ekachai","family":"Chaichanasiri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samroeng","family":"Inglam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jds.2025.11.009_bib1","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1111\/j.1600-0501.2008.01556.x","article-title":"Bone level changes at implants supporting crowns or fixed partial dentures with or without cantilevers","volume":"19","author":"H\u00e4lg","year":"2008","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.jds.2025.11.009_bib2","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1080\/10255842.2017.1287905","article-title":"Finite element analysis of implant-supported prosthesis with pontic and cantilever in the posterior maxilla","volume":"20","author":"de Souza Batista","year":"2017","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"10.1016\/j.jds.2025.11.009_bib3","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1016\/j.jds.2023.12.020","article-title":"Effects of diameters of implant and abutment screw on stress distribution within dental implant and alveolar bone: a three-dimensional finite element analysis","volume":"19","author":"Shen","year":"2024","journal-title":"J Dent Sci"},{"key":"10.1016\/j.jds.2025.11.009_bib4","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/j.jds.2023.11.001","article-title":"Effect of different implant locations and abutment types on stress and strain distribution under non-axial loading: a 3-dimensional finite element analysis","volume":"19","author":"Sakar","year":"2024","journal-title":"J Dent Sci"},{"key":"10.1016\/j.jds.2025.11.009_bib5","first-page":"30","article-title":"Finite element analysis on dental implant-supported prostheses without passive fit","volume":"11","author":"Kunavisarut","year":"2002","journal-title":"J Prosthodont"},{"key":"10.1016\/j.jds.2025.11.009_bib6","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.jds.2022.05.026","article-title":"Biomechanical evaluation of bridge span with three implant abutment designs and two connectors for tooth-implant supported prosthesis: a finite element analysis","volume":"18","author":"Huang","year":"2023","journal-title":"J Dent Sci"},{"key":"10.1016\/j.jds.2025.11.009_bib7","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/j.jds.2021.07.020","article-title":"Biomechanical analysis of rigid and non-rigid connection with implant abutment designs for tooth-implant supported prosthesis: a finite element analysis","volume":"17","author":"Huang","year":"2022","journal-title":"J Dent Sci"},{"key":"10.1016\/j.jds.2025.11.009_bib8","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1111\/j.1600-0501.2009.01706.x","article-title":"A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years","volume":"20","author":"Aglietta","year":"2009","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.jds.2025.11.009_bib9","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.prosdent.2020.11.005","article-title":"Patient-reported outcome measures and clinical assessment of implant-supported overdentures and fixed prostheses in mandibular edentulous patients: a systematic review and meta-analysis","volume":"127","author":"Borges","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.jds.2025.11.009_bib10","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.jds.2019.12.003","article-title":"The effect of implant neck microthread design on stress distribution of peri-implant bone with different level: a finite element analysis","volume":"15","author":"Jin","year":"2020","journal-title":"J Dent Sci"},{"key":"10.1016\/j.jds.2025.11.009_bib11","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/0022-3913(94)90189-9","article-title":"Effect of cantilever length on stress transfer by implant-supported prostheses","volume":"71","author":"White","year":"1994","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.jds.2025.11.009_bib12","first-page":"40","article-title":"Biomechanical load analysis of cantilevered implant systems","volume":"17","author":"Osier","year":"1991","journal-title":"J Oral Implantol"},{"key":"10.1016\/j.jds.2025.11.009_bib13","first-page":"1","article-title":"Compilation of stress concentration factors in the vicinity of a geometric discontinuity in structures","volume":"16","author":"Zengah","year":"2025","journal-title":"Acta Univ Sapientiae Electr Mech Eng"},{"key":"10.1016\/j.jds.2025.11.009_bib14","doi-asserted-by":"crossref","first-page":"127","DOI":"10.11607\/ijp.3947","article-title":"Screw- versus cement-retained implant prostheses: a systematic review of prosthodontic maintenance and complications","volume":"28","author":"Ma","year":"2015","journal-title":"Int J Prosthodont (IJP)"},{"key":"10.1016\/j.jds.2025.11.009_bib15","first-page":"793","article-title":"Retentiveness of dental cements used with metallic implant components","volume":"16","author":"Squier","year":"2001","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.jds.2025.11.009_bib16","doi-asserted-by":"crossref","first-page":"199","DOI":"10.3390\/jfb15070199","article-title":"The influence of cement thickness within the cap on stress distribution for dental implants","volume":"15","author":"Ceddia","year":"2024","journal-title":"J Funct Biomater"},{"key":"10.1016\/j.jds.2025.11.009_bib17","doi-asserted-by":"crossref","first-page":"315","DOI":"10.4047\/jap.2017.9.4.315","article-title":"Analysis of crown size and morphology, and gingival shape in the maxillary anterior dentition in korean young adults","volume":"9","author":"Song","year":"2017","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.jds.2025.11.009_bib18","doi-asserted-by":"crossref","first-page":"454","DOI":"10.2319\/050714-330.1","article-title":"Initial force systems during bodily tooth movement with plastic aligners and composite attachments: a three-dimensional finite element analysis","volume":"85","author":"Gomez","year":"2015","journal-title":"Angle Orthod"},{"key":"10.1016\/j.jds.2025.11.009_bib19","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.dental.2005.04.034","article-title":"The influence of different core material on the FEA-determined stress distribution in dental crowns","volume":"22","author":"De Jager","year":"2006","journal-title":"Dent Mater"},{"key":"10.1016\/j.jds.2025.11.009_bib20","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1016\/S0142-9612(97)00021-5","article-title":"Elastic modulus of the periodontal ligament","volume":"18","author":"Rees","year":"1997","journal-title":"Biomaterials"},{"key":"10.1016\/j.jds.2025.11.009_bib21","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.medengphy.2007.02.005","article-title":"A complete finite element model of a mandibular implant-retained overdenture with two implants: comparison between rigid and resilient attachment configurations","volume":"30","author":"Daas","year":"2008","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.jds.2025.11.009_bib22","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1111\/j.1532-849X.2010.00650.x","article-title":"The effects of adhesive type and thickness on stress distribution in molars restored with all-ceramic crowns","volume":"20","author":"Liu","year":"2011","journal-title":"J Prosthodont"},{"key":"10.1016\/j.jds.2025.11.009_bib23","series-title":"Dental biomechanics","first-page":"111","article-title":"Testing the reliability of dental implant devices","author":"Soncini","year":"2003"},{"key":"10.1016\/j.jds.2025.11.009_bib24","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1046\/j.0305-182X.2003.01179.x","article-title":"Single tooth bite forces in healthy young adults","volume":"31","author":"Ferrario","year":"2004","journal-title":"J Oral Rehabil"},{"key":"10.1016\/j.jds.2025.11.009_bib25","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1046\/j.1365-2842.2003.01123.x","article-title":"3-D finite element analysis of all-ceramic posterior crowns","volume":"30","author":"Imanishi","year":"2003","journal-title":"J Oral Rehabil"},{"key":"10.1016\/j.jds.2025.11.009_bib26","doi-asserted-by":"crossref","first-page":"121","DOI":"10.11607\/jomi.7744","article-title":"Effects of cantilever length and implant inclination on the stress distribution of mandibular prosthetic restorations constructed from monolithic zirconia ceramic","volume":"35","author":"Durkan","year":"2020","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.jds.2025.11.009_bib27","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2024.106872","article-title":"Biomechanical behavior of cantilevered 3-unit implant-supported prostheses made of pekk and monolithic zirconia: a finite element study","volume":"163","author":"Sadek","year":"2025","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.jds.2025.11.009_bib28","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/S0022-3913(96)90300-5","article-title":"Analysis of strain at selected bone sites of a cantilevered implant-supported prosthesis","volume":"76","author":"Tashkandi","year":"1996","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.jds.2025.11.009_bib29","doi-asserted-by":"crossref","first-page":"896","DOI":"10.3390\/prosthesis6040065","article-title":"Biomechanical factors in the prognosis of implants: a clinical study","volume":"6","author":"Ceresuela","year":"2024","journal-title":"Prosthesis"},{"key":"10.1016\/j.jds.2025.11.009_bib30","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.ijom.2014.10.023","article-title":"Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: a systematic review","volume":"44","author":"Moraschini","year":"2015","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.jds.2025.11.009_bib31","first-page":"65","article-title":"Implant occlusion: biomechanical considerations for implant-supported prostheses","volume":"3","author":"Chen","year":"2008","journal-title":"J Dent Sci"},{"key":"10.1016\/j.jds.2025.11.009_bib32","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1097\/SCS.0b013e318207477c","article-title":"Influence of implant angulation with different crowns on stress distribution","volume":"22","author":"Pellizzer","year":"2011","journal-title":"J Craniofac Surg"},{"key":"10.1016\/j.jds.2025.11.009_bib33","first-page":"8","article-title":"Stress riser in orthopedics","volume":"1","author":"Souza","year":"2022","journal-title":"Glob J Orthop Res"},{"key":"10.1016\/j.jds.2025.11.009_bib34","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1016\/0022-3913(92)90077-N","article-title":"The cantilever fixed partial denture--a literature review","volume":"67","author":"Himmel","year":"1992","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.jds.2025.11.009_bib35","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.14219\/jada.archive.2010.0049","article-title":"Cantilevers extending from unilateral implant-supported fixed prostheses: a review of the literature and presentation of practical guidelines","volume":"141","author":"Greenstein","year":"2010","journal-title":"J Am Dent Assoc"},{"key":"10.1016\/j.jds.2025.11.009_bib36","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2023.106059","article-title":"Measurement of tooth displacement","volume":"146","author":"Jansen van Vuuren","year":"2023","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.jds.2025.11.009_bib37","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1111\/j.1600-0501.2008.01699.x","article-title":"Five-year results of fixed implant-supported rehabilitations with distal cantilevers for the edentulous mandible","volume":"20","author":"Gallucci","year":"2009","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.jds.2025.11.009_bib38","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/ar.1092190104","article-title":"Bone \"mass\" and the \"mechanostat\": a proposal","volume":"219","author":"Frost","year":"1987","journal-title":"Anat Rec"},{"key":"10.1016\/j.jds.2025.11.009_bib39","doi-asserted-by":"crossref","DOI":"10.3390\/ma18143344","article-title":"Effect of crestal position on bone-implant stress interface of three-implant splinted prostheses: a finite element analysis","volume":"18","author":"Ceddia","year":"2025","journal-title":"Materials"},{"key":"10.1016\/j.jds.2025.11.009_bib40","doi-asserted-by":"crossref","DOI":"10.1111\/eos.12791","article-title":"The influence of the resin-based cement layer on ceramic-dentin bond strength","volume":"129","author":"Aker Sagen","year":"2021","journal-title":"Eur J Oral Sci"},{"key":"10.1016\/j.jds.2025.11.009_bib41","doi-asserted-by":"crossref","first-page":"99","DOI":"10.4186\/ej.2015.19.2.99","article-title":"Effect of periodontal ligament on stress distribution and displacement of tooth and bone structure using finite element simulation","volume":"19","author":"Fongsamootr","year":"2015","journal-title":"Eng J"},{"key":"10.1016\/j.jds.2025.11.009_bib42","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S1991-7902(10)60001-3","article-title":"The effects of splinting periodontally compromised removable partial denture abutments on bone stresses: a three-dimensional finite element study","volume":"5","author":"Geramy","year":"2010","journal-title":"J Dent Sci"}],"container-title":["Journal of Dental Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1991790225004088?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1991790225004088?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T09:26:01Z","timestamp":1774949161000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1991790225004088"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11]]},"references-count":42,"alternative-id":["S1991790225004088"],"URL":"https:\/\/doi.org\/10.1016\/j.jds.2025.11.009","relation":{},"ISSN":["1991-7902"],"issn-type":[{"value":"1991-7902","type":"print"}],"subject":[],"published":{"date-parts":[[2025,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The influence of the connector position placing, cement thickness and load direction on biomechanical performance of implant supported mesial cantilever: Finite element analysis","name":"articletitle","label":"Article Title"},{"value":"Journal of Dental Sciences","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jds.2025.11.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Association for Dental Sciences of the Republic of China. Publishing services by Digital Commons.","name":"copyright","label":"Copyright"}]}}