{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T17:36:33Z","timestamp":1791826593313,"version":"4.3.4"},"reference-count":36,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Electrocardiology"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1016\/j.jelectrocard.2026.154204","type":"journal-article","created":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T07:52:39Z","timestamp":1770277959000},"page":"154204","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Toward self-validating ECG Systems: A personalized, uncertainty-aware approach for detecting and estimating lead misplacement"],"prefix":"10.1016","volume":"95","author":[{"given":"Alireza","family":"Rafiei","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Trisha","family":"Dwivedi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-6205-6544","authenticated-orcid":false,"given":"Joel","family":"Xue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4234-2274","authenticated-orcid":false,"given":"Daphne E.","family":"Schlesinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nasim","family":"Katebi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5099-6438","authenticated-orcid":false,"given":"David E.","family":"Albert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gari D.","family":"Clifford","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jelectrocard.2026.154204_b1","series-title":"Goldberger\u2019s clinical electrocardiography","volume":"vol. 10","author":"Goldberger","year":"2018"},{"key":"10.1016\/j.jelectrocard.2026.154204_b2","series-title":"Comput cardiol","first-page":"1175","article-title":"New computer program for detecting 12 lead ECG misplacement using a 3D Kinect camera","author":"van Dam","year":"2013"},{"issue":"6","key":"10.1016\/j.jelectrocard.2026.154204_b3","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1016\/j.jelectrocard.2016.08.009","article-title":"Human factors analysis of the CardioQuick Patch\u00ae: a novel engineering solution to the problem of electrode misplacement during 12-lead electrocardiogram acquisition","volume":"49","author":"Bond","year":"2016","journal-title":"J Electrocardiol"},{"issue":"2","key":"10.1016\/j.jelectrocard.2026.154204_b4","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.ajem.2006.06.018","article-title":"Electrocardiographic artifacts due to electrode misplacement and their frequency in different clinical settings","volume":"25","author":"Rudiger","year":"2007","journal-title":"Am J Emerg Med"},{"issue":"1","key":"10.1016\/j.jelectrocard.2026.154204_b5","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1111\/j.1742-1241.2007.01390..x","article-title":"Accuracy in ECG lead placement among technicians, nurses, general physicians and cardiologists","volume":"62","author":"Rajaganeshan","year":"2008","journal-title":"Int J Clin Pract"},{"issue":"5","key":"10.1016\/j.jelectrocard.2026.154204_b6","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/j.jelectrocard.2008.06.006","article-title":"The influence of cardiograph design and automated algorithms on the incidence and detection of electrode cable reversals in an academic electrocardiogram laboratory","volume":"41","author":"Nilsson","year":"2008","journal-title":"J Electrocardiol"},{"issue":"6","key":"10.1016\/j.jelectrocard.2026.154204_b7","doi-asserted-by":"crossref","first-page":"29","DOI":"10.56068\/JGDQ2473","article-title":"Assessing the accuracy of ECG chest electrode placement by EMS and clinical personnel using two evaluation methods","author":"Clopton","year":"2024","journal-title":"Int J Paramed"},{"issue":"4","key":"10.1016\/j.jelectrocard.2026.154204_b8","doi-asserted-by":"crossref","first-page":"125","DOI":"10.54996\/anatolianjem.978965","article-title":"Evaluation of ECG recording applications of non-physician healthcare workers working in emergency departments","volume":"4","author":"Aydemir","year":"2021","journal-title":"Anatol J Emerg Med"},{"issue":"3","key":"10.1016\/j.jelectrocard.2026.154204_b9","doi-asserted-by":"crossref","first-page":"153","DOI":"10.3390\/bios14030153","article-title":"Sensitivity of electrocardiogram on electrode-pair locations for wearable devices: computational analysis of amplitude and waveform distortion","volume":"14","author":"Sanjo","year":"2024","journal-title":"Biosensors"},{"issue":"5","key":"10.1016\/j.jelectrocard.2026.154204_b10","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1016\/j.jelectrocard.2018.07.008","article-title":"Modified positioning of a smartphone based single-lead electrocardiogram device improves detection of atrial flutter","volume":"51","author":"Rajakariar","year":"2018","journal-title":"J Electrocardiol"},{"issue":"5","key":"10.1016\/j.jelectrocard.2026.154204_b11","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1016\/j.ajem.2018.02.006","article-title":"Misplacing V1 and V2 can have clinical consequences","volume":"36","author":"Walsh","year":"2018","journal-title":"Am J Emerg Med"},{"issue":"7","key":"10.1016\/j.jelectrocard.2026.154204_b12","article-title":"Precordial ECG lead mispositioning: its incidence and estimated cost to healthcare","volume":"12","author":"Rehman","year":"2020","journal-title":"Cureus"},{"issue":"2","key":"10.1016\/j.jelectrocard.2026.154204_b13","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1007\/s11517-013-1115-9","article-title":"The effect of precordial lead displacement on ECG morphology","volume":"52","author":"Kania","year":"2014","journal-title":"Med Biol Eng Comput"},{"issue":"7","key":"10.1016\/j.jelectrocard.2026.154204_b14","first-page":"1","article-title":"Examining the causes and effects of electrode misplacement during electrocardiography: a literature review","volume":"14","author":"Pearce","year":"2019","journal-title":"Br J Card Nurs"},{"issue":"11","key":"10.1016\/j.jelectrocard.2026.154204_b15","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1001\/jamainternmed.2022.3703","article-title":"Is it really alternating bundle-branch block?","volume":"182","author":"Wang","year":"2022","journal-title":"JAMA Intern Med"},{"key":"10.1016\/j.jelectrocard.2026.154204_b16","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.ajem.2023.10.009","article-title":"ECG lead misplacement in the frontal and horizontal plane mimicking a myocardial infarction","volume":"74","author":"Kaisbain","year":"2023","journal-title":"Am J Emerg Med"},{"issue":"7","key":"10.1016\/j.jelectrocard.2026.154204_b17","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1016\/j.ajem.2003.08.007","article-title":"Influence of electrode misplacement on the electrocardiographic signs of inferior myocardial ischemia","volume":"21","author":"Rudiger","year":"2003","journal-title":"Am J Emerg Med"},{"issue":"7","key":"10.1016\/j.jelectrocard.2026.154204_b18","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1016\/j.ejim.2012.03.011","article-title":"The effects of electrode misplacement on clinicians\u2019 interpretation of the standard 12-lead electrocardiogram","volume":"23","author":"Bond","year":"2012","journal-title":"Eur J Intern Med"},{"key":"10.1016\/j.jelectrocard.2026.154204_b19","series-title":"Comput cardiol","first-page":"531","article-title":"The effect of precordial lead displacement on P-wave morphology in body surface potential mapping","author":"Kania","year":"2013"},{"key":"10.1016\/j.jelectrocard.2026.154204_b20","series-title":"Ural symp biomed eng radioelectron inf technol","first-page":"40","article-title":"Effects of lead position, cardiac rhythm variation and drug-induced QT prolongation on performance of machine learning methods for ECG processing","author":"Bogdanov","year":"2020"},{"key":"10.1016\/j.jelectrocard.2026.154204_b21","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.jelectrocard.2020.08.013","article-title":"Machine learning techniques for detecting electrode misplacement and interchanges when recording ECGs: a systematic review and meta-analysis","volume":"62","author":"Rjoob","year":"2020","journal-title":"J Electrocardiol"},{"issue":"2","key":"10.1016\/j.jelectrocard.2026.154204_b22","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1054\/jelc.2001.23927","article-title":"Use of the sinus p wave in diagnosing electrocardiographic limb lead misplacement not involving the right leg (ground) lead","volume":"34","author":"Ho","year":"2001","journal-title":"J Electrocardiol"},{"key":"10.1016\/j.jelectrocard.2026.154204_b23","series-title":"Comput cardiol","first-page":"519","article-title":"Detection of electrode interchange in precordial and orthogonal ECG leads","author":"Jekova","year":"2013"},{"key":"10.1016\/j.jelectrocard.2026.154204_b24","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.cmpb.2016.06.003","article-title":"Inter-lead correlation analysis for automated detection of cable reversals in 12\/16-lead ECG","volume":"134","author":"Jekova","year":"2016","journal-title":"Comput Methods Programs Biomed"},{"issue":"6","key":"10.1016\/j.jelectrocard.2026.154204_b25","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/j.jelectrocard.2014.08.006","article-title":"Automatic detection of ECG cable interchange by analyzing both morphology and interlead relations","volume":"47","author":"Han","year":"2014","journal-title":"J Electrocardiol"},{"issue":"6","key":"10.1016\/j.jelectrocard.2026.154204_b26","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1016\/j.jelectrocard.2014.08.015","article-title":"The development and validation of an early warning system to prevent the acquisition of 12-lead resting ECGs with interchanged electrode positions","volume":"47","author":"de Bie","year":"2014","journal-title":"J Electrocardiol"},{"key":"10.1016\/j.jelectrocard.2026.154204_b27","series-title":"Philips DXL ECG algorithm for resting ECGs","author":"Philips Healthcare","year":"2025"},{"key":"10.1016\/j.jelectrocard.2026.154204_b28","series-title":"CardioVIT AT-102 G2","author":"SCHILLER","year":"2021"},{"issue":"4","key":"10.1016\/j.jelectrocard.2026.154204_b29","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/S0002-9149(01)01686-1","article-title":"Accurate automatic detection of electrode interchange in the electrocardiogram","volume":"88","author":"Kors","year":"2001","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jelectrocard.2026.154204_b30","series-title":"Comput cardiol","first-page":"1","article-title":"Machine learning improves the detection of misplaced V1 and V2 electrodes during 12-lead electrocardiogram acquisition","author":"Rjoob","year":"2019"},{"issue":"4","key":"10.1016\/j.jelectrocard.2026.154204_b31","article-title":"Reliable deep learning\u2013based detection of misplaced chest electrodes during electrocardiogram recording: algorithm development and validation","volume":"9","author":"Rjoob","year":"2021","journal-title":"JMIR Med Inf"},{"issue":"5","key":"10.1016\/j.jelectrocard.2026.154204_b32","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6579\/ad43ae","article-title":"A lightweight deep learning approach for detecting electrocardiographic lead misplacement","volume":"45","author":"Huang","year":"2024","journal-title":"Physiol Meas"},{"issue":"45","key":"10.1016\/j.jelectrocard.2026.154204_b33","doi-asserted-by":"crossref","first-page":"34195","DOI":"10.1007\/s11042-020-09054-7","article-title":"Revisiting spatial dropout for regularizing convolutional neural networks","volume":"79","author":"Lee","year":"2020","journal-title":"Multimedia Tools Appl"},{"key":"10.1016\/j.jelectrocard.2026.154204_b34","unstructured":"Ramachandran P, Zoph B, Le QV. Searching for Activation Functions. In: Int conf learn represent workshop track. 2018."},{"key":"10.1016\/j.jelectrocard.2026.154204_b35","series-title":"Int conf mach learn","first-page":"1050","article-title":"Dropout as a Bayesian approximation: representing model uncertainty in deep learning","author":"Gal","year":"2016"},{"issue":"8","key":"10.1016\/j.jelectrocard.2026.154204_b36","doi-asserted-by":"crossref","first-page":"4363","DOI":"10.3390\/app15084363","article-title":"Monte Carlo dropout neural networks for forecasting sinusoidal time series: Performance evaluation and uncertainty quantification","volume":"15","author":"Kummaraka","year":"2025","journal-title":"Appl Sci"}],"container-title":["Journal of Electrocardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002207362600021X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002207362600021X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T13:05:28Z","timestamp":1775480728000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S002207362600021X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":36,"alternative-id":["S002207362600021X"],"URL":"https:\/\/doi.org\/10.1016\/j.jelectrocard.2026.154204","relation":{},"ISSN":["0022-0736"],"issn-type":[{"value":"0022-0736","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Toward self-validating ECG Systems: A personalized, uncertainty-aware approach for detecting and estimating lead misplacement","name":"articletitle","label":"Article Title"},{"value":"Journal of Electrocardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jelectrocard.2026.154204","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"154204"}}