{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T01:50:18Z","timestamp":1791251418209,"version":"4.1.0"},"reference-count":30,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2013,2,1]],"date-time":"2013-02-01T00:00:00Z","timestamp":1359676800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"name":"MICINN of the Spanish Government","award":["TEC2008-02754"],"award-info":[{"award-number":["TEC2008-02754"]}]},{"name":"MICINN of the Spanish Government","award":["DPI2011-22680"],"award-info":[{"award-number":["DPI2011-22680"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Electromyography and Kinesiology"],"published-print":{"date-parts":[[2013,2]]},"DOI":"10.1016\/j.jelekin.2012.06.009","type":"journal-article","created":{"date-parts":[[2012,7,20]],"date-time":"2012-07-20T22:32:07Z","timestamp":1342823527000},"page":"33-42","source":"Crossref","is-referenced-by-count":69,"title":["Identification of isometric contractions based on High Density EMG maps"],"prefix":"10.1016","volume":"23","author":[{"given":"M.","family":"Rojas-Mart\u00ednez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.A.","family":"Ma\u00f1anas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.F.","family":"Alonso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Merletti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jelekin.2012.06.009_b0005","series-title":"An introduction to multivariate statistical analysis","author":"Anderson","year":"1984"},{"key":"10.1016\/j.jelekin.2012.06.009_b0010","doi-asserted-by":"crossref","unstructured":"Andreasen DS, Alien SK, Backus DA. Exoskeleton with EMG based active assistance for rehabilitation. In: Proc. 9th International Conference on Rehabilitation Robotics, 2005. pp. 333.","DOI":"10.1109\/ICORR.2005.1501113"},{"issue":"2","key":"10.1016\/j.jelekin.2012.06.009_b0015","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.physio.2010.05.005","article-title":"Increased EMG response following electromyographic biofeedback treatment of rectus femoris muscle after spinal cord injury","volume":"97","author":"De Biase","year":"2011","journal-title":"Physiotherapy"},{"issue":"3","key":"10.1016\/j.jelekin.2012.06.009_b0020","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1109\/TNSRE.2005.850423","article-title":"Customized interactive robotic treatment for stroke: EMG-triggered therapy","volume":"13","author":"Dipietro","year":"2005","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"7","key":"10.1016\/j.jelekin.2012.06.009_b0025","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1109\/TBME.2003.813539","article-title":"A robust, real-time control scheme for multifunction myoelectric control","volume":"50","author":"Englehart","year":"2003","journal-title":"IEEE Trans Biomed Eng"},{"issue":"3","key":"10.1016\/j.jelekin.2012.06.009_b0030","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/S1050-6411(00)00051-1","article-title":"Evaluation of intra-muscular EMG signal decomposition algorithms","volume":"11","author":"Farina","year":"2001","journal-title":"J Electromyogr Kinesiol"},{"issue":"1","key":"10.1016\/j.jelekin.2012.06.009_b0035","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.jelekin.2006.08.005","article-title":"The change in spatial distribution of upper trapezius muscle activity is correlated to contraction duration","volume":"18","author":"Farina","year":"2008","journal-title":"J Electromyogr Kinesiol"},{"key":"10.1016\/j.jelekin.2012.06.009_b0040","series-title":"SENIAM 9: European Recommendations for Surface ElectroMyoGraphy, results of the SENIAM project (CD)","author":"Freriks","year":"1999"},{"issue":"5","key":"10.1016\/j.jelekin.2012.06.009_b0045","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1109\/TBME.2006.889192","article-title":"A comparison of surface and intramuscular myoelectric signal classification","volume":"54","author":"Hargrove","year":"2007","journal-title":"IEEE Trans Biomed Eng"},{"issue":"5","key":"10.1016\/j.jelekin.2012.06.009_b0050","doi-asserted-by":"crossref","first-page":"1407","DOI":"10.1109\/TBME.2008.2008171","article-title":"Principal components analysis preprocessing for improved classification accuracies in pattern-recognition-based myoelectric control","volume":"56","author":"Hargrove","year":"2009","journal-title":"IEEE Trans Biomed Eng"},{"issue":"5","key":"10.1016\/j.jelekin.2012.06.009_b0055","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1016\/j.jelekin.2011.05.008","article-title":"Differences in the log-transformed electromyographic\u2013force relationships of the plantar flexors between high- and moderate-activated subjects","volume":"21","author":"Herda","year":"2011","journal-title":"J Electromyogr Kinesiol"},{"issue":"5","key":"10.1016\/j.jelekin.2012.06.009_b0060","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1682\/JRRD.2005.06.0103","article-title":"Motions or muscles? Some behavioral factors underlying robotic assistance of motor recovery","volume":"43","author":"Hogan","year":"2006","journal-title":"J Rehabil Res Dev"},{"issue":"2","key":"10.1016\/j.jelekin.2012.06.009_b0065","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.jelekin.2004.09.003","article-title":"Inhomogeneities in muscle activation reveal motor unit recruitment","volume":"15","author":"Holtermann","year":"2005","journal-title":"J Electromyogr Kinesiol"},{"issue":"6","key":"10.1016\/j.jelekin.2012.06.009_b0070","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1162\/089976699300016304","article-title":"Algorithmic stability and sanity-check bounds for leave-one-out cross-validation","volume":"11","author":"Kearns","year":"1999","journal-title":"Neural Comput"},{"key":"10.1016\/j.jelekin.2012.06.009_b0075","series-title":"Muscles: testing and function","author":"Kendall","year":"1993"},{"key":"10.1016\/j.jelekin.2012.06.009_b0080","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/1475-925X-9-41","article-title":"Surface EMG pattern recognition for real-time control of a wrist exoskeleton","volume":"9","author":"Khokhar","year":"2010","journal-title":"Biomed Eng Online"},{"key":"10.1016\/j.jelekin.2012.06.009_b0085","series-title":"Principles of multivariate analysis: a user\u2019s perspective","author":"Krzanowski","year":"1988"},{"issue":"11","key":"10.1016\/j.jelekin.2012.06.009_b0090","doi-asserted-by":"crossref","first-page":"2436","DOI":"10.1016\/j.clinph.2006.06.753","article-title":"Experimental muscle pain changes the spatial distribution of upper trapezius muscle activity during sustained contraction","volume":"117","author":"Madeleine","year":"2006","journal-title":"Clin Neurophysiol"},{"key":"10.1016\/j.jelekin.2012.06.009_b0095","series-title":"Electromyography: physiology, engineering, and non-invasive applications","author":"Merletti","year":"2004"},{"issue":"4","key":"10.1016\/j.jelekin.2012.06.009_b0100","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1615\/CritRevBiomedEng.v38.i4.10","article-title":"Advances in surface EMG: recent progress in detection and processing techniques","volume":"38","author":"Merletti","year":"2010","journal-title":"Crit Rev Biomed Eng"},{"issue":"4","key":"10.1016\/j.jelekin.2012.06.009_b0105","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1615\/CritRevBiomedEng.v38.i4.20","article-title":"Advances in surface EMG: recent progress in clinical research applications","volume":"38","author":"Merletti","year":"2010","journal-title":"Crit Rev Biomed Eng"},{"issue":"6","key":"10.1016\/j.jelekin.2012.06.009_b0110","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1016\/j.jelekin.2006.08.006","article-title":"Myoelectric signal processing for control of powered limb prostheses","volume":"16","author":"Parker","year":"2006","journal-title":"J Electromyogr Kinesiol"},{"key":"10.1016\/j.jelekin.2012.06.009_b0115","unstructured":"Rojas-Mart\u00ednez M, Ma\u00f1anas MA, Alonso JF. High-density surface EMG maps from upper-arm and forearm muscles. J Neuroeng Rehabil, submitted for publication."},{"issue":"6","key":"10.1016\/j.jelekin.2012.06.009_b0120","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1682\/JRRD.2010.09.0177","article-title":"Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use","volume":"48","author":"Scheme","year":"2011","journal-title":"J Rehabil Res Dev"},{"issue":"5","key":"10.1016\/j.jelekin.2012.06.009_b0125","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1016\/j.jelekin.2008.04.013","article-title":"Heterogeneity of muscle activation in relation to force direction: a multi-channel surface electromyography study on the triceps surae muscle","volume":"19","author":"Staudenmann","year":"2009","journal-title":"J Electromyogr Kinesiol"},{"issue":"3","key":"10.1016\/j.jelekin.2012.06.009_b0130","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.jelekin.2009.08.005","article-title":"Methodological aspects of SEMG recordings for force estimation \u2013 a tutorial and review","volume":"20","author":"Staudenmann","year":"2010","journal-title":"J Electromyogr Kinesiol"},{"key":"10.1016\/j.jelekin.2012.06.009_b0135","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/1743-0003-7-21","article-title":"Study of stability of time-domain features for electromyographic pattern recognition","volume":"7","author":"Tkach","year":"2010","journal-title":"J Neuroeng Rehabil"},{"issue":"3","key":"10.1016\/j.jelekin.2012.06.009_b0140","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/j.jelekin.2007.10.003","article-title":"Electromyographic mapping of the erector spinae muscle with varying load and during sustained contraction","volume":"19","author":"Tucker","year":"2009","journal-title":"J Electromyogr Kinesiol"},{"issue":"2","key":"10.1016\/j.jelekin.2012.06.009_b0145","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1109\/83.217222","article-title":"Morphological grayscale reconstruction in image analysis: applications and efficient algorithms","volume":"2","author":"Vincent","year":"1993","journal-title":"IEEE Trans Image Process"},{"issue":"1","key":"10.1016\/j.jelekin.2012.06.009_b0150","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/mus.10358","article-title":"Multichannel surface EMG: basic aspects and clinical utility","volume":"28","author":"Zwarts","year":"2003","journal-title":"Muscle Nerve"}],"container-title":["Journal of Electromyography and Kinesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1050641112001198?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1050641112001198?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,11,22]],"date-time":"2018-11-22T01:23:30Z","timestamp":1542849810000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1050641112001198"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,2]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,2]]}},"alternative-id":["S1050641112001198"],"URL":"https:\/\/doi.org\/10.1016\/j.jelekin.2012.06.009","relation":{},"ISSN":["1050-6411"],"issn-type":[{"value":"1050-6411","type":"print"}],"subject":[],"published":{"date-parts":[[2013,2]]}}}