{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T15:12:55Z","timestamp":1761059575936,"version":"build-2065373602"},"reference-count":22,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jem-journal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Emergency Medicine"],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1016\/j.jemermed.2013.04.031","type":"journal-article","created":{"date-parts":[[2013,8,9]],"date-time":"2013-08-09T18:29:37Z","timestamp":1376072977000},"page":"373-377","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Focused Cardiac Ultrasound Diagnosis of Thoracic Aortic Aneurysm: Two Cases"],"prefix":"10.1016","volume":"46","author":[{"given":"Michael C.","family":"Daignault","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Turandot","family":"Saul","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Resa E.","family":"Lewiss","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jemermed.2013.04.031_bib1","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.jvs.2012.04.053","article-title":"Natural history of thoracic aortic aneurysms","volume":"56","author":"Kuzmik","year":"2012","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jemermed.2013.04.031_bib2","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1111\/j.1553-2712.2011.01279.x","article-title":"Point-of-care focused cardiac ultrasound for the assessment of thoracic aortic dimensions, dilation, and aneurysmal disease","volume":"19","author":"Taylor","year":"2012","journal-title":"Acad Emerg Med"},{"key":"10.1016\/j.jemermed.2013.04.031_bib3","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1016\/j.echo.2010.10.005","article-title":"Focused cardiac ultrasound in the emergent setting: a consensus statement of the American Society of Echocardiography and American College of Emergency Physicians","volume":"23","author":"Labovitz","year":"2010","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.jemermed.2013.04.031_bib4","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1148\/rg.292075080","article-title":"Multidetector CT of thoracic aortic aneurysms","volume":"29","author":"Agarwal","year":"2009","journal-title":"RadioGraphics"},{"key":"10.1016\/j.jemermed.2013.04.031_bib5","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1067\/mtc.2002.122310","article-title":"Diameters of the thoracic aorta throughout life as measured with helical computed tomography","volume":"123","author":"Hager","year":"2002","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jemermed.2013.04.031_bib6","unstructured":"Tseng E, Bush E. Thoracic aortic aneurysm. Medscape reference. Last updated 3 Oct 2012. Available at: http:\/\/www.emedicine.medscape.com\/article\/424904-overview. Accessed March 26,\u00a02013."},{"key":"10.1016\/j.jemermed.2013.04.031_bib7","series-title":"Diagnostic radiology: a textbook of medical imaging","first-page":"854","article-title":"The thoracic aorta","author":"Lesko","year":"1997"},{"key":"10.1016\/j.jemermed.2013.04.031_bib8","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.athoracsur.2005.06.026","article-title":"Novel measurement of relative aortic size predicts rupture of thoracic aortic aneurysms","volume":"81","author":"Davies","year":"2006","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jemermed.2013.04.031_bib9","first-page":"175","article-title":"Thoracic aortic aneurysm: reading the enemy's playbook","volume":"81","author":"Elefteriades","year":"2008","journal-title":"Yale J Biol Med"},{"key":"10.1016\/j.jemermed.2013.04.031_bib10","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/S0022-5223(94)70054-0","article-title":"The natural history of thoracic aortic aneurysms","volume":"107","author":"Dapunt","year":"1994","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jemermed.2013.04.031_bib11","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1016\/S0741-5214(95)70227-X","article-title":"Ruptured thoracic aortic aneurysms: a study of incidence and mortality rates","volume":"21","author":"Johansson","year":"1995","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jemermed.2013.04.031_bib12","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1016\/j.jemermed.2010.04.005","article-title":"Rupture of an ascending and descending thoracic aortic aneurysm causing tension hemothorax: a case report","volume":"43","author":"Pizon","year":"2012","journal-title":"J Emerg Med"},{"key":"10.1016\/j.jemermed.2013.04.031_bib13","doi-asserted-by":"crossref","first-page":"e23","DOI":"10.1111\/j.1553-2712.2010.00709.x","article-title":"Emergency ultrasound diagnosis of type A aortic dissection and apical pleural cap","volume":"17","author":"Barrett","year":"2010","journal-title":"Acad Emerg Med"},{"key":"10.1016\/j.jemermed.2013.04.031_bib14","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1001\/jama.283.7.897","article-title":"The International Registry of Acute Aortic Dissection (IRAD): new insights into an old disease","volume":"283","author":"Hagan","year":"2000","journal-title":"JAMA"},{"key":"10.1016\/j.jemermed.2013.04.031_bib15","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.jemermed.2006.07.020","article-title":"The diagnosis of aortic dissection by emergency medicine ultrasound","volume":"32","author":"Fojtik","year":"2007","journal-title":"J Emerg Med"},{"key":"10.1016\/j.jemermed.2013.04.031_bib16","series-title":"Acute aortic disease","first-page":"89","article-title":"Epidemiology, prevalence, incidence, trends","author":"Elefteriades","year":"2007"},{"key":"10.1016\/j.jemermed.2013.04.031_bib17","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1148\/radiographics.10.5.2217974","article-title":"CT of thoracic aortic aneurysms","volume":"10","author":"Posniak","year":"1990","journal-title":"RadioGraphics"},{"issue":"6 Suppl","key":"10.1016\/j.jemermed.2013.04.031_bib18","doi-asserted-by":"crossref","first-page":"S5","DOI":"10.1016\/j.jtcvs.2010.10.001","article-title":"Indications for aortic replacement","volume":"140","author":"Elefteriades","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jemermed.2013.04.031_bib19","doi-asserted-by":"crossref","first-page":"i3","DOI":"10.1093\/ejechocard\/jen243","article-title":"Structure and anatomy of the aortic root","volume":"10","author":"Yen Ho","year":"2009","journal-title":"Eur J Echocardiogr"},{"key":"10.1016\/j.jemermed.2013.04.031_bib20","series-title":"The echo manual","first-page":"20","article-title":"Transthoracic echocardiography: M-mode, two dimensional and three-dimensional","author":"Oh","year":"2006"},{"key":"10.1016\/j.jemermed.2013.04.031_bib21","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1002\/clc.20807","article-title":"Accuracy of transthoracic echocardiography for the measurement of the ascending aorta: comparison with transesophageal echocardiography","volume":"33","author":"Kabirdas","year":"2010","journal-title":"Clin Cardiol"},{"key":"10.1016\/j.jemermed.2013.04.031_bib22","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1053\/ajem.2002.33006","article-title":"Dissection of the proximal thoracic aorta: a new ultrasonographic sign in the subxiphoid view","volume":"20","author":"Blaivas","year":"2002","journal-title":"Am J Emerg Med"}],"container-title":["The Journal of Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0736467913005829?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0736467913005829?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:29:45Z","timestamp":1760027385000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0736467913005829"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,3]]}},"alternative-id":["S0736467913005829"],"URL":"https:\/\/doi.org\/10.1016\/j.jemermed.2013.04.031","relation":{},"ISSN":["0736-4679"],"issn-type":[{"type":"print","value":"0736-4679"}],"subject":[],"published":{"date-parts":[[2014,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Focused Cardiac Ultrasound Diagnosis of Thoracic Aortic Aneurysm: Two Cases","name":"articletitle","label":"Article Title"},{"value":"The Journal of Emergency Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jemermed.2013.04.031","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}