{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T12:28:45Z","timestamp":1763641725599,"version":"build-2065373602"},"reference-count":24,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jem-journal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Emergency Medicine"],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1016\/j.jemermed.2013.08.075","type":"journal-article","created":{"date-parts":[[2013,11,22]],"date-time":"2013-11-22T08:45:47Z","timestamp":1385109947000},"page":"335-340","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Hard to Diagnose and Potentially Fatal: Slow Aortic Erosion Post Spinal Fusion"],"prefix":"10.1016","volume":"46","author":[{"given":"Edmond W.K.","family":"Ip","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Victor C.","family":"Bourke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael C.","family":"Stacey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"Begley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jens C.","family":"Ritter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jemermed.2013.08.075_bib1","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1016\/j.jvs.2007.11.005","article-title":"Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature","volume":"47","author":"Kakkos","year":"2008","journal-title":"J Vasc Surg"},{"issue":"Suppl. 2","key":"10.1016\/j.jemermed.2013.08.075_bib2","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1007\/s00586-009-0974-0","article-title":"Delayed-iatrogenic injury of the thoracic aorta by an anterior spinal instrumentation","volume":"18","author":"Lavigne","year":"2009","journal-title":"Eur Spine J"},{"key":"10.1016\/j.jemermed.2013.08.075_bib3","doi-asserted-by":"crossref","first-page":"E1064","DOI":"10.1097\/BRS.0b013e3181ed29c1","article-title":"Descending aortic injury by a thoracic pedicle screw during posterior reconstructive surgery: a case report","volume":"35","author":"Watanabe","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"year":"1997","series-title":"Atlas of Human Anatomy","author":"Netter","key":"10.1016\/j.jemermed.2013.08.075_bib4"},{"key":"10.1016\/j.jemermed.2013.08.075_bib5","doi-asserted-by":"crossref","first-page":"492","DOI":"10.3928\/01477447-20090527-12","article-title":"Posterior versus anterior lumbar interbody fusion with anterior tension band plating: retrospective analysis","volume":"32","author":"Freudenberger","year":"2009","journal-title":"Orthopedics"},{"key":"10.1016\/j.jemermed.2013.08.075_bib6","first-page":"631","article-title":"Spontaneous abdominal aortic rupture from erosion by a lumbar spine fixation device: a case report","volume":"99","author":"Jendrisak","year":"1986","journal-title":"Surgery"},{"key":"10.1016\/j.jemermed.2013.08.075_bib7","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/0090-3019(86)90237-5","article-title":"Aortic laceration after anterior spinal fusion","volume":"25","author":"Woolsey","year":"1986","journal-title":"Surg Neurol"},{"key":"10.1016\/j.jemermed.2013.08.075_bib8","first-page":"136","article-title":"Extrinsic erosion of the descending aorta by a vertebral fixator","volume":"18","author":"Sokoli\u0107","year":"1991","journal-title":"Tex Heart Inst J"},{"key":"10.1016\/j.jemermed.2013.08.075_bib9","doi-asserted-by":"crossref","first-page":"2327","DOI":"10.1097\/00007632-199311000-00033","article-title":"Penetration of a screw into the thoracic aorta in anterior spinal instrumentation. A case report","volume":"18","author":"Matsuzaki","year":"1993","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.jemermed.2013.08.075_bib10","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1097\/00005373-199904000-00032","article-title":"Iatrogenic upper abdominal aortic injury with pseudoaneurysm during spinal surgery","volume":"46","author":"Lim","year":"1999","journal-title":"J Trauma"},{"issue":"2 Suppl.","key":"10.1016\/j.jemermed.2013.08.075_bib11","first-page":"253","article-title":"Delayed aortic rupture caused by an implanted anterior spinal device. Case report","volume":"95","author":"Ohnishi","year":"2001","journal-title":"J Neurosurg"},{"key":"10.1016\/j.jemermed.2013.08.075_bib12","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1097\/00005373-200101000-00029","article-title":"False aneurysm of the thoracic aorta associated with an aorto-chest wall fistula after spinal instrumentation","volume":"50","author":"Choi","year":"2001","journal-title":"J Trauma"},{"key":"10.1016\/j.jemermed.2013.08.075_bib13","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1016\/j.jvs.2003.10.056","article-title":"Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report","volume":"39","author":"Minor","year":"2004","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jemermed.2013.08.075_bib14","doi-asserted-by":"crossref","first-page":"E856","DOI":"10.1097\/01.brs.0000240761.13090.a9","article-title":"Endovascular graft for late iatrogenic vascular complication after anterior spinal instrumentation: a case report","volume":"31","author":"Been","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.jemermed.2013.08.075_bib15","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1016\/j.spinee.2007.03.007","article-title":"Pseudoaneurysm of the thoracoabdominal aorta caused by a severe migration of an anterior spinal device","volume":"8","author":"Higashino","year":"2008","journal-title":"Spine J"},{"key":"10.1016\/j.jemermed.2013.08.075_bib16","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1097\/BRS.0b013e3180592c4a","article-title":"The position of the aorta relative to the spine: is it mobile or not?","volume":"32","author":"Huitema","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.jemermed.2013.08.075_bib17","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.jtcvs.2006.03.052","article-title":"Surgical treatment of pseudoaneurysm of the thoracic aorta","volume":"132","author":"Atik","year":"2006","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jemermed.2013.08.075_bib18","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/0003-4975(91)90888-W","article-title":"Fistulas between the aorta and tracheobronchial tree","volume":"51","author":"MacIntosh","year":"1991","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jemermed.2013.08.075_bib19","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1097\/00004836-198706000-00020","article-title":"Aortoesophageal fistula. Review of clinical, radiographic, and endoscopic features","volume":"9","author":"Khawaja","year":"1987","journal-title":"J Clin Gastroenterol"},{"key":"10.1016\/j.jemermed.2013.08.075_bib20","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1097\/00000658-198203000-00011","article-title":"Aortoenteric fistula: incidence, presentation recognition, and management","volume":"195","author":"Champion","year":"1982","journal-title":"Ann Surg"},{"key":"10.1016\/j.jemermed.2013.08.075_bib21","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1016\/j.jvs.2011.05.010","article-title":"Emergency procedures on the descending thoracic aorta in the endovascular era","volume":"54","author":"Mitchell","year":"2011","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jemermed.2013.08.075_bib22","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1016\/j.jvs.2010.10.103","article-title":"Thoracic endovascular repair as a safe management strategy for aortobronchial fistulas","volume":"53","author":"Bailey","year":"2011","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jemermed.2013.08.075_bib23","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1016\/j.jvs.2009.03.001","article-title":"Thoracic endovascular aortic repair of aortobronchial fistulas","volume":"50","author":"Riesenman","year":"2009","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.jemermed.2013.08.075_bib24","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1016\/j.jtcvs.2006.11.066","article-title":"Have we gone too far? Endovascular stent-graft repair of aortobronchial fistulas","volume":"133","author":"Wheatley","year":"2007","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["The Journal of Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0736467913010664?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0736467913010664?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:29:28Z","timestamp":1760027368000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0736467913010664"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,3]]}},"alternative-id":["S0736467913010664"],"URL":"https:\/\/doi.org\/10.1016\/j.jemermed.2013.08.075","relation":{},"ISSN":["0736-4679"],"issn-type":[{"type":"print","value":"0736-4679"}],"subject":[],"published":{"date-parts":[[2014,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Hard to Diagnose and Potentially Fatal: Slow Aortic Erosion Post Spinal Fusion","name":"articletitle","label":"Article Title"},{"value":"The Journal of Emergency Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jemermed.2013.08.075","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Crown copyright \u00a9 2014 Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}