{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,3]],"date-time":"2026-04-03T19:04:16Z","timestamp":1775243056762,"version":"3.50.1"},"reference-count":12,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jem-journal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Emergency Medicine"],"published-print":{"date-parts":[[2018,5]]},"DOI":"10.1016\/j.jemermed.2018.02.010","type":"journal-article","created":{"date-parts":[[2018,3,27]],"date-time":"2018-03-27T00:23:31Z","timestamp":1522110211000},"page":"674-677","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Emergency Tracheal Intubation in an Ankylosing Spondylitis Patient in a Sitting Position Using an Airway Scope Combined with Face-to-Face and Digital Intubation"],"prefix":"10.1016","volume":"54","author":[{"given":"Pei-Shing","family":"Hsieh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hon-Ping","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chung-Shun","family":"Wong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiann Ruey","family":"Ong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jemermed.2018.02.010_bib1","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1016\/j.berh.2006.02.001","article-title":"Concepts and epidemiology of spondyloarthritis","volume":"20","author":"Sieper","year":"2006","journal-title":"Best Pract Res Clin Rheumatol"},{"key":"10.1016\/j.jemermed.2018.02.010_bib2","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1136\/emermed-2012-202064","article-title":"Inverse intubation in entrapped trauma casualties: a simulator based, randomised cross-over comparison of direct, indirect and video laryngoscopy","volume":"31","author":"Schober","year":"2014","journal-title":"Emerg Med J"},{"key":"10.1016\/j.jemermed.2018.02.010_bib3","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1016\/j.ajem.2006.11.045","article-title":"Digital tracheal intubation: an effective technique that should not be forgotten","volume":"25","author":"Shiber","year":"2007","journal-title":"Am J Emerg Med"},{"key":"10.1016\/j.jemermed.2018.02.010_bib4","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1016\/j.ajem.2006.03.001","article-title":"Is digital intubation an option for emergency physicians in definitive airway management?","volume":"24","author":"Young","year":"2006","journal-title":"Am J Emerg Med"},{"key":"10.1016\/j.jemermed.2018.02.010_bib5","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.aat.2010.12.004","article-title":"Pentax-airway scope for tracheal intubation breaks through the limitation of neck motion in an ankylosing spondylitis patient wearing halo vest\u2013a case report","volume":"48","author":"Cheng","year":"2010","journal-title":"Acta Anaesthesiol Taiwan"},{"key":"10.1016\/j.jemermed.2018.02.010_bib6","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/S1875-4597(08)60031-4","article-title":"Emergency tracheal intubation in an ankylosing spondylitis patient in the lateral position using the GlideScope","volume":"46","author":"Wang","year":"2008","journal-title":"Acta Anaesthesiol Taiwan"},{"key":"10.1016\/j.jemermed.2018.02.010_bib7","doi-asserted-by":"crossref","first-page":"38","DOI":"10.4103\/1658-354X.62616","article-title":"Retrograde intubation in a case of ankylosing spondylitis posted for correction of deformity of spine","volume":"4","author":"Raval","year":"2010","journal-title":"Saudi J Anaesth"},{"key":"10.1016\/j.jemermed.2018.02.010_bib8","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1093\/bja\/aep352","article-title":"McGrath videolaryngoscope for awake tracheal intubation in a patient with severe ankylosing spondylitis","volume":"104","author":"Uslu","year":"2010","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.jemermed.2018.02.010_bib9","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/ANA.0b013e31829a0491","article-title":"A comparison of the GlideScope with the Macintosh laryngoscope for nasotracheal intubation in patients with ankylosing spondylitis","volume":"26","author":"Lili","year":"2014","journal-title":"J Neurosurg Anesthesiol"},{"key":"10.1016\/j.jemermed.2018.02.010_bib10","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/j.annemergmed.2011.10.002","article-title":"Preoxygenation and prevention of desaturation during emergency airway management","volume":"59","author":"Weingart","year":"2012","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.jemermed.2018.02.010_bib11","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1080\/10903129908958911","article-title":"Inverse intubation: an important alternative for intubation in the streets","volume":"3","author":"Hilker","year":"1999","journal-title":"Prehosp Emerg Care"},{"key":"10.1016\/j.jemermed.2018.02.010_bib12","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1007\/s00134-014-3209-8","article-title":"Urgent face-to-face tracheal re-intubation using Video-Airtraq\u2122 in ICU patients placed in the sitting position","volume":"40","author":"Dhonneur","year":"2014","journal-title":"Intensive Care Med"}],"container-title":["The Journal of Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0736467918301197?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0736467918301197?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:40:22Z","timestamp":1760028022000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0736467918301197"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":12,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018,5]]}},"alternative-id":["S0736467918301197"],"URL":"https:\/\/doi.org\/10.1016\/j.jemermed.2018.02.010","relation":{},"ISSN":["0736-4679"],"issn-type":[{"value":"0736-4679","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Emergency Tracheal Intubation in an Ankylosing Spondylitis Patient in a Sitting Position Using an Airway Scope Combined with Face-to-Face and Digital Intubation","name":"articletitle","label":"Article Title"},{"value":"The Journal of Emergency Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jemermed.2018.02.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}