{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T16:00:53Z","timestamp":1782144053909,"version":"3.54.5"},"reference-count":20,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","jenonline.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Emergency Nursing"],"published-print":{"date-parts":[[2025,5]]},"DOI":"10.1016\/j.jen.2024.11.002","type":"journal-article","created":{"date-parts":[[2024,12,9]],"date-time":"2024-12-09T20:55:00Z","timestamp":1733777700000},"page":"480-486","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Inter-Rater Reliability of Ultrasonographic Measurements of Optic Nerve Sheath Diameter Performed by Emergency Nurses"],"prefix":"10.1016","volume":"51","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3494-5120","authenticated-orcid":false,"given":"Turgay Y\u0131lmaz","family":"Kilic","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yesim","family":"Eyler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6657-5654","authenticated-orcid":false,"given":"Birdal","family":"G\u00fcll\u00fcp\u0131nar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2357-1274","authenticated-orcid":false,"given":"Murat","family":"Yesilaras","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3645-5579","authenticated-orcid":false,"given":"Serhat","family":"Koran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"10","key":"10.1016\/j.jen.2024.11.002_bib1","doi-asserted-by":"crossref","first-page":"1950","DOI":"10.1016\/j.ajem.2016.06.098","article-title":"A randomized controlled trial assessing the use of ultrasound for nurse-performed IV placement in difficult access ED patients","volume":"34","author":"Bahl","year":"2016","journal-title":"Am J Emerg Med"},{"issue":"3","key":"10.1016\/j.jen.2024.11.002_bib2","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1097\/TME.0000000000000025","article-title":"Ultrasound measurement of inferior vena cava diameters by emergency department nurses","volume":"36","author":"De Lorenzo","year":"2014","journal-title":"Adv Emerg Nurs J"},{"issue":"5","key":"10.1016\/j.jen.2024.11.002_bib3","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1016\/j.injury.2009.08.009","article-title":"Validation of nurse-performed FAST ultrasound","volume":"41","author":"Bowra","year":"2010","journal-title":"Injury"},{"issue":"1","key":"10.1016\/j.jen.2024.11.002_bib4","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/2036-7902-6-2","article-title":"Detection of soft tissue foreign bodies by nurse practitioner-performed ultrasound","volume":"6","author":"Atkinson","year":"2014","journal-title":"Crit Ultrasound J"},{"issue":"3","key":"10.1016\/j.jen.2024.11.002_bib5","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.ienj.2010.08.004","article-title":"The ability of emergency nurses to detect simulated long bone fractures with portable ultrasound","volume":"19","author":"Heiner","year":"2011","journal-title":"Int Emerg Nurs"},{"issue":"1","key":"10.1016\/j.jen.2024.11.002_bib6","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.ajem.2007.03.020","article-title":"Volumetric bladder ultrasound performed by trained nurses increases catheterization success in pediatric patients","volume":"26","author":"Baumann","year":"2008","journal-title":"Am J Emerg Med"},{"issue":"4","key":"10.1016\/j.jen.2024.11.002_bib7","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.ienj.2014.03.003","article-title":"Lung ultrasound by emergency nursing as an aid for rapid triage of dyspneic patients: a pilot study","volume":"22","author":"\u00dcnl\u00fcer","year":"2014","journal-title":"Int Emerg Nurs"},{"key":"10.1016\/j.jen.2024.11.002_bib8","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.ejim.2020.03.007","article-title":"The reliability of ultrasound compression test performed by general ICU nurses in the critically ill patients: a preliminary prospective clinical study","volume":"76","author":"Skulec","year":"2020","journal-title":"Eur J Intern Med"},{"issue":"2","key":"10.1016\/j.jen.2024.11.002_bib9","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1177\/1129729820937131","article-title":"Procedural competency for ultrasound-guided peripheral intravenous catheter insertion for nurses in a pediatric emergency department","volume":"22","author":"Blick","year":"2021","journal-title":"J Vasc Access"},{"issue":"4","key":"10.1016\/j.jen.2024.11.002_bib10","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.jemermed.2014.09.060","article-title":"Accuracy of optic nerve sheath diameter measurement by emergency physicians using bedside ultrasound","volume":"48","author":"Hassen","year":"2015","journal-title":"J Emerg Med"},{"issue":"6","key":"10.1016\/j.jen.2024.11.002_bib11","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.neuchi.2017.06.001","article-title":"Role of serial ultrasonic optic nerve sheath diameter monitoring in head injury","volume":"63","author":"Thotakura","year":"2017","journal-title":"Neurochirurgie"},{"issue":"1","key":"10.1016\/j.jen.2024.11.002_bib12","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/s40477-014-0144-z","article-title":"Intra- and interobserver reliability of transorbital sonographic assessment of the optic nerve sheath diameter and optic nerve diameter in healthy adults","volume":"19","author":"Lochner","year":"2014","journal-title":"J Ultrasound"},{"issue":"1","key":"10.1016\/j.jen.2024.11.002_bib13","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1111\/j.1552-6569.2010.00546.x","article-title":"Intra- and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults","volume":"22","author":"B\u00e4uerle","year":"2012","journal-title":"J Neuroimaging"},{"issue":"8","key":"10.1016\/j.jen.2024.11.002_bib14","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1016\/j.kjms.2015.06.004","article-title":"Assessment of intra-interobserver reliability of the sonographic optic nerve sheath diameter measurement","volume":"31","author":"Cimilli Ozturk","year":"2015","journal-title":"Kaohsiung J Med Sci"},{"issue":"2","key":"10.1016\/j.jen.2024.11.002_bib15","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"issue":"5","key":"10.1016\/j.jen.2024.11.002_bib16","doi-asserted-by":"crossref","first-page":"e27","DOI":"10.1016\/j.annemergmed.2016.08.457","article-title":"Ultrasound guidelines: emergency, point-of-care, and clinical ultrasound guidelines in medicine","volume":"69","year":"2017","journal-title":"Ann Emerg Med"},{"issue":"3","key":"10.1016\/j.jen.2024.11.002_bib17","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/S0929-8266(02)00036-8","article-title":"Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults","volume":"15","author":"Ballantyne","year":"2002","journal-title":"Eur J Ultrasound"},{"issue":"1","key":"10.1016\/j.jen.2024.11.002_bib18","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s13089-016-0044-x","article-title":"A unique method for estimating the reliability learning curve of optic nerve sheath diameter ultrasound measurement","volume":"8","author":"Zeiler","year":"2016","journal-title":"Crit Ultrasound J"},{"issue":"7","key":"10.1016\/j.jen.2024.11.002_bib19","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1111\/j.1745-7599.2010.00518.x","article-title":"Emergency department ultrasound by nurse practitioners","volume":"22","author":"Henderson","year":"2010","journal-title":"J Am Acad Nurse Pract"},{"issue":"2","key":"10.1016\/j.jen.2024.11.002_bib20","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.jen.2022.01.002","article-title":"Verification of endotracheal tube position by emergency nurses using ultrasound: a repeated measures cadaver study","volume":"48","author":"Sa\u011flam","year":"2022","journal-title":"J Emerg Nurs"}],"container-title":["Journal of Emergency Nursing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0099176724003325?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0099176724003325?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T05:47:08Z","timestamp":1750225628000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0099176724003325"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["S0099176724003325"],"URL":"https:\/\/doi.org\/10.1016\/j.jen.2024.11.002","relation":{},"ISSN":["0099-1767"],"issn-type":[{"value":"0099-1767","type":"print"}],"subject":[],"published":{"date-parts":[[2025,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Inter-Rater Reliability of Ultrasonographic Measurements of Optic Nerve Sheath Diameter Performed by Emergency Nurses","name":"articletitle","label":"Article Title"},{"value":"Journal of Emergency Nursing","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jen.2024.11.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Emergency Nurses Association. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}