{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T18:45:10Z","timestamp":1786992310951,"version":"build-2736575974"},"reference-count":27,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,11,1]],"date-time":"2020-11-01T00:00:00Z","timestamp":1604188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,11,1]],"date-time":"2020-11-01T00:00:00Z","timestamp":1604188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001807","name":"Funda\u00e7\u00e3o de Amparo \u00e0 Pesquisa do Estado de S\u00e3o Paulo","doi-asserted-by":"publisher","award":["11\/13913-9"],"award-info":[{"award-number":["11\/13913-9"]}],"id":[{"id":"10.13039\/501100001807","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Equine Veterinary Science"],"published-print":{"date-parts":[[2020,11]]},"DOI":"10.1016\/j.jevs.2020.103252","type":"journal-article","created":{"date-parts":[[2020,9,12]],"date-time":"2020-09-12T03:02:50Z","timestamp":1599879770000},"page":"103252","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["Comparison of a 3-hole 4.5-mm Dynamic Compression Plate and a 7-hole 5.5-mm Y Locking Compression Plate for Arthrodesis of the Proximal Interphalangeal Joint in Horses\u2014an Ex\u00a0Vivo Biomechanical Study"],"prefix":"10.1016","volume":"94","author":[{"given":"Carlos Adolfo Salazar","family":"Latorre","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8066-4787","authenticated-orcid":false,"given":"Anderson Fernando","family":"de Souza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paula Andrea Ram\u00edrez","family":"Ramos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernanda Silveira","family":"N\u00f3brega","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guilherme Maia Mulder","family":"van de Graaf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C\u00e9sar Augusto Martins","family":"Pereira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C\u00e1ssio Ricardo Auada","family":"Ferrigno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dean A.","family":"Hendrickson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andr\u00e9 Lu\u00eds do Valle","family":"De Zoppa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jevs.2020.103252_bib1","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1053\/jvet.2001.25873","article-title":"Proximal interphalangeal joint arthrodesis in 34 horses using two parallel 5.5-mm cortical bone screws","volume":"30","author":"MacLellan","year":"2001","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib2","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1111\/j.1532-950X.2005.00022.x","article-title":"Arthrodesis of the equine proximal interphalangeal joint: a mechanical comparison of 2 parallel 5.5 mm cortical screws and 3 parallel 5.5 mm cortical screws","volume":"34","author":"Read","year":"2005","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib3","first-page":"303","article-title":"A\u00a0limited surgical approach for pastern arthrodesis in horses with severe osteoarthritis","volume":"22","author":"Jones","year":"2009","journal-title":"Vet Comp Orthop Traumatol"},{"key":"10.1016\/j.jevs.2020.103252_bib4","doi-asserted-by":"crossref","first-page":"538","DOI":"10.2746\/042516406X154840","article-title":"Proximal interphalangeal joint arthrodesis using a combination plate-screw technique in 53 horses (1994-2003)","volume":"38","author":"Knox","year":"2006","journal-title":"Equine Vet J"},{"key":"10.1016\/j.jevs.2020.103252_bib5","first-page":"E3","article-title":"The equine pastern","volume":"33","author":"Carpenter","year":"2011","journal-title":"Compend Contin Educ Vet"},{"key":"10.1016\/j.jevs.2020.103252_bib6","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.cveq.2005.07.004","article-title":"Arthrodesis techniques in horses","volume":"21","author":"Zubrod","year":"2005","journal-title":"Vet Clin North Am Equine Pract"},{"key":"10.1016\/j.jevs.2020.103252_bib7","series-title":"Equine Surg","first-page":"1374","article-title":"Arthrodesis techniques","author":"Lischer","year":"2019"},{"key":"10.1016\/j.jevs.2020.103252_bib8","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1111\/j.1532-950X.1990.tb01167.x","article-title":"Proximal interphalangeal arthrodesis in the horse. A retrospective study and a modified screw technique","volume":"19","author":"Caron","year":"1990","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib9","doi-asserted-by":"crossref","DOI":"10.1053\/jvet.2001.23353","article-title":"Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of three 4.5-mm and two 5.5-mm cortical screws","volume":"30","author":"Watt","year":"2001","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib10","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1111\/j.1532-950X.2011.00817.x","article-title":"An in\u00a0vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: two parallel transarticular headless tapered variable pitch screws versus two parallel transarticular AO cortical bone screws inserted in lag fashion","volume":"40","author":"Gudehus","year":"2011","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib11","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1111\/j.1532-950X.2000.00152.x","article-title":"A\u00a0biomechanical comparison of double-plate and Y-plate fixation for comminuted equine second phalangeal fractures","volume":"29","author":"Galuppo","year":"2000","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib12","doi-asserted-by":"crossref","first-page":"1458","DOI":"10.2460\/javma.1995.207.11.1458","article-title":"Double-plate fixation of comminuted fractures of the second phalanx in horses: 10 cases (1985-1993)","volume":"207","author":"Crabill","year":"1995","journal-title":"J\u00a0Am Vet Med Assoc"},{"key":"10.1016\/j.jevs.2020.103252_bib13","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1111\/j.1532-950X.2007.00338.x","article-title":"In\u00a0vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: Prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion","volume":"36","author":"Sod","year":"2007","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib14","series-title":"Equine Fract. Repair","first-page":"277","article-title":"Arthrodesis of the proximal interphalangeal joint","author":"Watkins","year":"2020"},{"key":"10.1016\/j.jevs.2020.103252_bib15","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1111\/j.1532-950X.2010.00792.x","article-title":"Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 3-hole 4.5 mm locking compression plate and 3-hole 4.5 mm narrow dynamic compression plate, with two transarticular 5.5 mm cortex screws","volume":"40","author":"Zoppa","year":"2011","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib16","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1097\/BTO.0b013e318157822d","article-title":"Locked plating: biomechanics and biology and locked plating - clinical indications","volume":"22","author":"Raschke","year":"2007","journal-title":"Tech Orthop"},{"key":"10.1016\/j.jevs.2020.103252_bib17","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1097\/BTO.0b013e3181501047","article-title":"Biomechanics of plate osteosynthesis","volume":"22","author":"Frigg","year":"2007","journal-title":"Tech Orthop"},{"key":"10.1016\/j.jevs.2020.103252_bib18","series-title":"Locking plates Vet. Orthop","first-page":"51","article-title":"Principles of locking plate applications in large animals","author":"Gasiorowski","year":"2018"},{"key":"10.1016\/j.jevs.2020.103252_bib19","doi-asserted-by":"crossref","first-page":"246","DOI":"10.2746\/042516406776866291","article-title":"Minimally invasive plate fixation of lower limb injury in horses: 32 cases (1999-2003)","volume":"38","author":"James","year":"2010","journal-title":"Equine Vet J"},{"key":"10.1016\/j.jevs.2020.103252_bib20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1055\/s-0037-1616579","article-title":"3D kinematics of the interphalangeal joints in the forelimb of walking and trotting horses","volume":"20","author":"Clayton","year":"2007","journal-title":"Vet Comp Orthop Traumatol"},{"key":"10.1016\/j.jevs.2020.103252_bib21","first-page":"217","article-title":"Pastern joint motion in trotting horses","volume":"46","author":"Clayton","year":"2000","journal-title":"AAEP Proc"},{"key":"10.1016\/j.jevs.2020.103252_bib22","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.injury.2003.09.023","article-title":"General principles for the clinical use of the LCP","volume":"34","author":"Wagner","year":"2003","journal-title":"Injury"},{"key":"10.1016\/j.jevs.2020.103252_bib23","doi-asserted-by":"crossref","DOI":"10.1053\/jvet.2002.29457","article-title":"Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of two 7-hole 3.5-mm broad and two 5-hole 4.5-mm narrow dynamic compression plates","volume":"31","author":"Watt","year":"2002","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib24","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1111\/j.1532-950X.2010.00794.x","article-title":"Evaluation of ethyl alcohol for use in a minimally invasive technique for equine proximal interphalangeal joint arthrodesis","volume":"40","author":"Wolker","year":"2011","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib25","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1111\/j.1532-950X.2011.00830.x","article-title":"A\u00a0mechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial locking compression plate and two abaxial transarticular cortical screws versus an axial dynamic compression plate and two abaxial transarticular cortical Sc","volume":"40","author":"Sod","year":"2011","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib26","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1111\/j.1532-950X.2009.00615.x","article-title":"An in\u00a0vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular","volume":"39","author":"Sod","year":"2010","journal-title":"Vet Surg"},{"key":"10.1016\/j.jevs.2020.103252_bib27","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1111\/j.1532-950X.2010.00741.x","article-title":"Effect of a collateral ligament sparing surgical approach on mechanical properties of equine proximal interphalangeal joint arthrodesis constructs","volume":"40","author":"Bras","year":"2011","journal-title":"Vet Surg"}],"container-title":["Journal of Equine Veterinary Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0737080620303439?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0737080620303439?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:49:38Z","timestamp":1760032178000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0737080620303439"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11]]},"references-count":27,"alternative-id":["S0737080620303439"],"URL":"https:\/\/doi.org\/10.1016\/j.jevs.2020.103252","relation":{},"ISSN":["0737-0806"],"issn-type":[{"value":"0737-0806","type":"print"}],"subject":[],"published":{"date-parts":[[2020,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of a 3-hole 4.5-mm Dynamic Compression Plate and a 7-hole 5.5-mm Y Locking Compression Plate for Arthrodesis of the Proximal Interphalangeal Joint in Horses\u2014an Ex\u00a0Vivo Biomechanical Study","name":"articletitle","label":"Article Title"},{"value":"Journal of Equine Veterinary Science","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jevs.2020.103252","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"103252"}}