{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T11:28:52Z","timestamp":1784892532085,"version":"3.55.0"},"reference-count":35,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,4,1]],"date-time":"2018-04-01T00:00:00Z","timestamp":1522540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,4,1]],"date-time":"2018-04-01T00:00:00Z","timestamp":1522540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Forensic and Legal Medicine"],"published-print":{"date-parts":[[2018,4]]},"DOI":"10.1016\/j.jflm.2018.02.013","type":"journal-article","created":{"date-parts":[[2018,2,14]],"date-time":"2018-02-14T13:15:47Z","timestamp":1518614147000},"page":"52-57","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":19,"special_numbering":"C","title":["Eye injuries from electrical weapon probes: Incidents, prevalence, and legal implications"],"prefix":"10.1016","volume":"55","author":[{"given":"Mark W.","family":"Kroll","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mollie B.","family":"Ritter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric A.","family":"Kennedy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nora K.","family":"Silverman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roman","family":"Shinder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael A.","family":"Brave","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Howard E.","family":"Williams","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"12","key":"10.1016\/j.jflm.2018.02.013_bib1","doi-asserted-by":"crossref","first-page":"2268","DOI":"10.2105\/AJPH.2009.159616","article-title":"The effect of less-lethal weapons on injuries in police use-of-force events","volume":"99","author":"MacDonald","year":"2009","journal-title":"Am J Public Health"},{"key":"10.1016\/j.jflm.2018.02.013_bib2","doi-asserted-by":"crossref","DOI":"10.1177\/1098611114548098","article-title":"The influence of agency policies on conducted energy device use and police use of lethal force","author":"Ferdik","year":"2014","journal-title":"Police Q"},{"issue":"6","key":"10.1016\/j.jflm.2018.02.013_bib3","first-page":"1567","article-title":"Conductive electrical devices: a prospective, population-based study of the medical safety of law enforcement use","volume":"64","author":"Eastman","year":"2008","journal-title":"J Trauma"},{"issue":"1","key":"10.1016\/j.jflm.2018.02.013_bib4","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1161\/CIRCULATIONAHA.113.004401","article-title":"TASER electronic control devices and cardiac arrests: coincidental or causal?","volume":"129","author":"Kroll","year":"2014","journal-title":"Circulation"},{"issue":"5","key":"10.1016\/j.jflm.2018.02.013_bib5","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1007\/s00194-016-0117-y","article-title":"Welfare effects of substituting traditional police ballistic weapons with non-lethal alternatives: medico-economic comparative study","volume":"26","author":"Grove","year":"2016","journal-title":"Rechtsmedizin"},{"issue":"4","key":"10.1016\/j.jflm.2018.02.013_bib6","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1007\/s12024-012-9346-x","article-title":"Conducted electrical weapon incapacitation during a goal-directed task as a function of probe spread","volume":"8","author":"Ho","year":"2012","journal-title":"Forensic Sci Med Pathol"},{"issue":"2","key":"10.1016\/j.jflm.2018.02.013_bib7","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/s12024-014-9551-x","article-title":"Incapacitation recovery times from a conductive electrical weapon exposure","volume":"10","author":"Criscione","year":"2014","journal-title":"Forensic Sci Med Pathol"},{"key":"10.1016\/j.jflm.2018.02.013_bib8","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jflm.2016.07.001","article-title":"Fatal traumatic brain injury with electrical weapon falls","volume":"43","author":"Kroll","year":"2016","journal-title":"J Forensic Leg Med"},{"issue":"6","key":"10.1016\/j.jflm.2018.02.013_bib9","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/j.scijus.2014.04.004","article-title":"The ignitability of petrol vapours and potential for vapour phase explosion by use of TASER(R) law enforcement electronic control device","volume":"54","author":"Clarke","year":"2014","journal-title":"Sci Justice"},{"key":"10.1016\/j.jflm.2018.02.013_bib10","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.jflm.2017.06.001","article-title":"Fatal and non-fatal burn injuries with electrical weapons and explosive fumes","volume":"50","author":"Kroll","year":"2017","journal-title":"J Forensic Leg Med"},{"key":"10.1016\/j.jflm.2018.02.013_bib11","series-title":"TASER Conducted Electrical Weapons: Physiology, Pathology, and Law","article-title":"Field statistics overview","author":"Brewer","year":"2009"},{"issue":"5","key":"10.1016\/j.jflm.2018.02.013_bib12","first-page":"1239","article-title":"Conducted electrical weapon use by law enforcement: an evaluation of safety and injury","volume":"68","author":"Strote","year":"2010","journal-title":"J Trauma"},{"issue":"4","key":"10.1016\/j.jflm.2018.02.013_bib13","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1016\/j.annemergmed.2008.11.021","article-title":"Safety and injury profile of conducted electrical weapons used by law enforcement officers against criminal suspects","volume":"53","author":"Bozeman","year":"2009","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.jflm.2018.02.013_bib14","article-title":"Injuries associated with police use of force","author":"Bozeman","year":"2017","journal-title":"J Trauma Acute Care Surg"},{"key":"10.1016\/j.jflm.2018.02.013_bib15","first-page":"6505","article-title":"In silico estimates of cell electroporation by electrical incapacitation waveforms","volume":"2009","author":"Gowrishankar","year":"2009","journal-title":"Conf Proc IEEE EMBC"},{"issue":"6","key":"10.1016\/j.jflm.2018.02.013_bib16","doi-asserted-by":"crossref","first-page":"1556","DOI":"10.1111\/1556-4029.13148","article-title":"Infection risk from conducted electrical weapon probes: what do we know?","volume":"61","author":"Kroll","year":"2016","journal-title":"J Forensic Sci"},{"issue":"3","key":"10.1016\/j.jflm.2018.02.013_bib17","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1111\/j.1540-8159.2009.02612.x","article-title":"Electrical characteristics of an electronic control device under a physiologic load: a brief report. Pacing and clinical electrophysiology","volume":"33","author":"Dawes","year":"2010","journal-title":"PACE"},{"issue":"1","key":"10.1016\/j.jflm.2018.02.013_bib18","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/00005373-198501000-00003","article-title":"Cataracts: a long-term complication of electrical injury","volume":"25","author":"Saffle","year":"1985","journal-title":"J Trauma"},{"issue":"2","key":"10.1016\/j.jflm.2018.02.013_bib19","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/s10633-011-9287-9","article-title":"Diffuse retinal injury from a non-penetrating TASER dart","volume":"123","author":"Sayegh","year":"2011","journal-title":"Doc Ophthalmol"},{"issue":"9","key":"10.1016\/j.jflm.2018.02.013_bib20","doi-asserted-by":"crossref","first-page":"1664","DOI":"10.1016\/j.jcrs.2007.04.037","article-title":"Cataract secondary to electrical shock from a Taser gun","volume":"33","author":"Seth","year":"2007","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"10.1016\/j.jflm.2018.02.013_bib21","doi-asserted-by":"crossref","DOI":"10.1016\/j.ajem.2016.01.005","article-title":"Emergent diagnosis and management of TASER penetrating ocular injury","volume":"34","author":"Jey","year":"2016","journal-title":"Am J Emerg Med"},{"issue":"9","key":"10.1016\/j.jflm.2018.02.013_bib22","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1177\/000313480807400920","article-title":"Taser and Taser associated injuries: a case series","volume":"74","author":"Mangus","year":"2008","journal-title":"Am Surg"},{"key":"10.1016\/j.jflm.2018.02.013_bib23","unstructured":"Forrest v. Prine. 620 F.3d 739. 7th Cir, (Illinois); 2010."},{"key":"10.1016\/j.jflm.2018.02.013_bib24","unstructured":"Hernandez v City of Beaumont. Case No. EDCV 13\u201300967 DDP (DTBx). (US CD CA). 2016."},{"key":"10.1016\/j.jflm.2018.02.013_bib25","unstructured":"Stephens v. City of Tarrant, Slip Copy, 2017 WL 34829 (N.D.Ala. Jan. 4, 2017)."},{"key":"10.1016\/j.jflm.2018.02.013_bib26","unstructured":"Khansari v. City of Houston, 14 F.Supp.3d 842 (S.D.Tex.) Apr. 9, 2014."},{"key":"10.1016\/j.jflm.2018.02.013_bib27","unstructured":"Nelson v. City of Davis, 685 F.3d 867. 9th Cir. (Cal.) Jul. 11, 2012."},{"issue":"4","key":"10.1016\/j.jflm.2018.02.013_bib28","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1016\/j.ajo.2004.11.039","article-title":"Taser penetrating ocular injury","volume":"139","author":"Ng","year":"2005","journal-title":"Am J Ophthalmol"},{"issue":"4","key":"10.1016\/j.jflm.2018.02.013_bib29","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1111\/j.1442-9071.2006.01228.x","article-title":"Perforating ocular injury by TASER\u00ae","volume":"34","author":"Chen","year":"2006","journal-title":"Clin Experiment Ophthalmol"},{"issue":"1","key":"10.1016\/j.jflm.2018.02.013_bib30","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1017\/S1481803500010976","article-title":"Ophthalmic injuries from a TASER","volume":"11","author":"Han","year":"2009","journal-title":"Cjem"},{"issue":"5","key":"10.1016\/j.jflm.2018.02.013_bib31","first-page":"590","article-title":"A case of penetrating eye injury induced by Taser gun","volume":"20","author":"Park","year":"2009","journal-title":"J Kor Soc Emerg Med"},{"issue":"4","key":"10.1016\/j.jflm.2018.02.013_bib32","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/IOP.0b013e3181c15c36","article-title":"Perforating globe injury from Taser trauma","volume":"26","author":"Teymoorian","year":"2010","journal-title":"Ophthal Plast Reconstr Surg"},{"issue":"1","key":"10.1016\/j.jflm.2018.02.013_bib33","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.jemermed.2011.03.010","article-title":"Catastrophic globe disruption as a result of a TASER injury","volume":"44","author":"Li","year":"2013","journal-title":"The J Emerg Med"},{"issue":"3S Suppl 1","key":"10.1016\/j.jflm.2018.02.013_bib34","doi-asserted-by":"crossref","first-page":"S176","DOI":"10.1097\/IOP.0000000000000486","article-title":"Impaled orbital TASER probe injury requiring primary enucleation","volume":"33","author":"Rafailov","year":"2017","journal-title":"Ophthal Plast Reconstr Surg"},{"issue":"2","key":"10.1016\/j.jflm.2018.02.013_bib35","first-page":"1","article-title":"Penetrating ocular injury from Taser","volume":"2","author":"Cahill","year":"2015","journal-title":"Austin J Clin Ophthalmol"}],"container-title":["Journal of Forensic and Legal Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1752928X18300295?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1752928X18300295?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T00:12:46Z","timestamp":1761696766000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1752928X18300295"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4]]},"references-count":35,"alternative-id":["S1752928X18300295"],"URL":"https:\/\/doi.org\/10.1016\/j.jflm.2018.02.013","relation":{},"ISSN":["1752-928X"],"issn-type":[{"value":"1752-928X","type":"print"}],"subject":[],"published":{"date-parts":[[2018,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Eye injuries from electrical weapon probes: Incidents, prevalence, and legal implications","name":"articletitle","label":"Article Title"},{"value":"Journal of Forensic and Legal Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jflm.2018.02.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.","name":"copyright","label":"Copyright"}]}}