{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T23:11:05Z","timestamp":1777504265614,"version":"3.51.4"},"reference-count":20,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2018,4,1]],"date-time":"2018-04-01T00:00:00Z","timestamp":1522540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,4,1]],"date-time":"2018-04-01T00:00:00Z","timestamp":1522540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal Fran\u00e7ais d'Ophtalmologie"],"published-print":{"date-parts":[[2018,4]]},"DOI":"10.1016\/j.jfo.2017.12.006","type":"journal-article","created":{"date-parts":[[2018,4,21]],"date-time":"2018-04-21T10:57:21Z","timestamp":1524308241000},"page":"302-307","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"title":["Low-power versus medium-power toric intraocular lenses in cataract surgery, about 110 eyes"],"prefix":"10.1016","volume":"41","author":[{"given":"A.","family":"Mairot","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"El Chehab","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E.","family":"Agard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Rezkallah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"V.","family":"Bouteleux","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Dot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jfo.2017.12.006_bib0105","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/1471-2415-12-41","article-title":"Visual acuity improvements after implantation of toric intraocular lenses in cataract patients with astigmatism: a systematic review","volume":"12","author":"Agresta","year":"2012","journal-title":"BMC Ophthalmol"},{"key":"10.1016\/j.jfo.2017.12.006_bib0110","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.jcrs.2008.11.043","article-title":"Toric intraocular lens versus opposite clear corneal incisions to correct astigmatism in eyes having cataract surgery","volume":"35","author":"Mendicute","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jfo.2017.12.006_bib0115","doi-asserted-by":"crossref","first-page":"1700","DOI":"10.1016\/j.jcrs.2010.04.043","article-title":"Comparison of toric intraocular lenses and peripheral corneal relaxing incisions to treat astigmatism during cataract surgery","volume":"36","author":"Mingo-Bot\u00edn","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jfo.2017.12.006_bib0120","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1097\/APO.0000000000000112","article-title":"Evaluation of toric intraocular lenses in patients with low degrees of astigmatism","volume":"4","author":"Levitz","year":"2015","journal-title":"Asia Pac J Ophthalmol Phila Pa"},{"key":"10.1016\/j.jfo.2017.12.006_bib0125","first-page":"324","article-title":"Cataract surgery in eyes with low corneal astigmatism: implantation of the acrysof IQ toric SN6AT2 intraocular lens","volume":"9","author":"Aujla","year":"2014","journal-title":"J Ophthalmic Vis Res"},{"key":"10.1016\/j.jfo.2017.12.006_bib0130","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1097\/00006324-199707000-00020","article-title":"Effect of small focal errors on vision","volume":"74","author":"Miller","year":"1997","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.jfo.2017.12.006_bib0135","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.jcrs.2008.09.027","article-title":"Prevalence of corneal astigmatism before cataract surgery","volume":"35","author":"Ferrer-Blasco","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jfo.2017.12.006_bib0140","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1016\/j.jcrs.2010.02.025","article-title":"Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes","volume":"36","author":"Hoffmann","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jfo.2017.12.006_bib0145","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1016\/j.jfo.2013.03.006","article-title":"[Optical quality after 2.2mm microincisional cataract surgery with bimanual I\/A in 154\u00a0eyes]","volume":"36","author":"Dot","year":"2013","journal-title":"J Fr Ophtalmol"},{"key":"10.1016\/j.jfo.2017.12.006_bib0150","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.survophthal.2003.10.010","article-title":"Practical astigmatism analysis for refractive outcomes in cataract and refractive surgery","volume":"49","author":"Alpins","year":"2004","journal-title":"Surv Ophthalmol"},{"key":"10.1016\/j.jfo.2017.12.006_bib0155","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1001\/jamaophthalmol.2016.1351","article-title":"Effectiveness and safety of an intracameral injection of cefuroxime for the prevention of endophthalmitis after cataract surgery with or without perioperative capsular rupture","volume":"134","author":"Daien","year":"2016","journal-title":"JAMA Ophthalmol"},{"key":"10.1016\/j.jfo.2017.12.006_bib0160","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.ophtha.2015.10.002","article-title":"Toric intraocular lenses in the correction of astigmatism during cataract surgery: a systematic review and meta-analysis","volume":"123","author":"Kessel","year":"2016","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jfo.2017.12.006_bib0165","doi-asserted-by":"crossref","first-page":"5424713","DOI":"10.1155\/2016\/5424713","article-title":"Refractive and quality of vision outcomes with toric iol implantation in low astigmatism","volume":"2016","author":"Buscacio","year":"2016","journal-title":"J Ophthalmol"},{"key":"10.1016\/j.jfo.2017.12.006_bib0170","first-page":"703","article-title":"Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker","volume":"9","author":"Farooqui","year":"2016","journal-title":"Int J Ophthalmol"},{"key":"10.1016\/j.jfo.2017.12.006_bib0175","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1016\/j.jcrs.2017.07.030","article-title":"Comparison of visual outcomes, alignment accuracy, and surgical time between 2\u00a0methods of corneal marking for toric intraocular lens implantation","volume":"43","author":"Mayer","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jfo.2017.12.006_bib0180","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1016\/j.jcrs.2013.02.020","article-title":"Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications","volume":"39","author":"Visser","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jfo.2017.12.006_bib0185","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.1016\/j.jcrs.2011.02.024","article-title":"Accuracy of toric intraocular lens implantation in cataract and refractive surgery","volume":"37","author":"Visser","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jfo.2017.12.006_bib0190","doi-asserted-by":"crossref","first-page":"194","DOI":"10.3928\/1081597X-20130129-02","article-title":"Efficacy and stability of AT TORBI 709M toric IOL","volume":"29","author":"Bascaran","year":"2013","journal-title":"J Refract Surg"},{"key":"10.1016\/j.jfo.2017.12.006_bib0195","first-page":"796","article-title":"[Evaluation of postoperative astigmatism correction and postoperative rotational stability of two toric intraocular lenses]","volume":"234","author":"Grohlich","year":"2017","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"10.1016\/j.jfo.2017.12.006_bib0200","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.jcrs.2015.11.036","article-title":"Effect of posterior corneal astigmatism on power calculation and alignment of toric intraocular lenses: comparison of methodologies","volume":"42","author":"Reitblat","year":"2016","journal-title":"J Cataract Refract Surg"}],"container-title":["Journal Fran\u00e7ais d'Ophtalmologie"],"original-title":[],"language":"fr","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0181551218301086?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0181551218301086?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T19:08:03Z","timestamp":1759259283000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0181551218301086"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,4]]}},"alternative-id":["S0181551218301086"],"URL":"https:\/\/doi.org\/10.1016\/j.jfo.2017.12.006","relation":{},"ISSN":["0181-5512"],"issn-type":[{"value":"0181-5512","type":"print"}],"subject":[],"published":{"date-parts":[[2018,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Low-power versus medium-power toric intraocular lenses in cataract surgery, about 110 eyes","name":"articletitle","label":"Article Title"},{"value":"Journal Fran\u00e7ais d'Ophtalmologie","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jfo.2017.12.006","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Masson SAS. All rights reserved.","name":"copyright","label":"Copyright"}]}}