{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T01:06:46Z","timestamp":1790730406133,"version":"4.1.0"},"reference-count":38,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T00:00:00Z","timestamp":1740441600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal Fran\u00e7ais d'Ophtalmologie"],"published-print":{"date-parts":[[2025,4]]},"DOI":"10.1016\/j.jfo.2025.104469","type":"journal-article","created":{"date-parts":[[2025,3,8]],"date-time":"2025-03-08T23:44:36Z","timestamp":1741477476000},"page":"104469","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Real-world comparison of efficacy and safety of XEN45 implant with phacoemulsification versus iStent inject\u00ae W with phacoemulsification"],"prefix":"10.1016","volume":"48","author":[{"given":"A.L.","family":"Mendoza-Moreira","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.T.","family":"Marcos-Parra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"de Bari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Ezbakhe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Espa\u00f1a-Vera","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.C.","family":"Calatayud-Hern\u00e1ndez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.J.","family":"P\u00e9rez-Santonja","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"Suppl 1","key":"10.1016\/j.jfo.2025.104469_bib0005","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1136\/bjophthalmol-2021-egsguidelines","article-title":"Terminology and guidelines for glaucoma","volume":"105","author":"European Glaucoma","year":"2021","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0010","doi-asserted-by":"crossref","first-page":"2081","DOI":"10.1016\/j.ophtha.2014.05.013","article-title":"Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis","volume":"121","author":"Tham","year":"2014","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jfo.2025.104469_bib0015","doi-asserted-by":"crossref","first-page":"2551","DOI":"10.2147\/OPTH.S257361","article-title":"GlaucoMap\u00a0\u2013\u00a0distribution of glaucoma surgical procedures in the United States","volume":"14","author":"Ma","year":"2020","journal-title":"Clin Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0020","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1080\/08820538.2021.1903513","article-title":"Microinvasive glaucoma surgery: an evidence-based review","volume":"36","author":"Birnbaum","year":"2021","journal-title":"Semin Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0025","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1097\/ICU.0b013e32834ff1e7","article-title":"Micro-invasive glaucoma surgery: current perspectives and future directions","volume":"23","author":"Saheb","year":"2012","journal-title":"Curr Opin Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0030","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1097\/j.jcrs.0000000000000325","article-title":"iStent inject: comprehensive review","volume":"47","author":"Shalaby","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jfo.2025.104469_bib0035","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s12325-014-0095-y","article-title":"Prospective, unmasked evaluation of the iStent\u00ae inject system for open-angle glaucoma: synergy trial","volume":"31","author":"Voskanyan","year":"2014","journal-title":"Adv Ther"},{"key":"10.1016\/j.jfo.2025.104469_bib0040","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1016\/j.ophtha.2019.03.006","article-title":"Prospective, randomized, controlled pivotal trial of an ab interno implanted trabecular micro-bypass in primary open-angle glaucoma and cataract: two-year results","volume":"126","author":"Samuelson","year":"2019","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jfo.2025.104469_bib0045","doi-asserted-by":"crossref","first-page":"1056573","DOI":"10.1155\/2016\/1056573","article-title":"Glaukos iStent inject\u00ae trabecular micro-bypass implantation associated with cataract surgery in patients with coexisting cataract and open-angle glaucoma or ocular hypertension: a long-term study","volume":"2016","author":"Arriola-Villalobos","year":"2016","journal-title":"J Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0050","doi-asserted-by":"crossref","first-page":"4881","DOI":"10.3390\/jcm10214881","article-title":"Evaluation of the efficacy and safety of canaloplasty and istent bypass implantation in patients with open-angle glaucoma: a review of the literature","volume":"10","author":"Go\u0142aszewska","year":"2021","journal-title":"J Clin Med"},{"key":"10.1016\/j.jfo.2025.104469_bib0055","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1080\/17434440.2018.1419060","article-title":"XEN Gel Implant: a new surgical approach in glaucoma","volume":"15","author":"Chaudhary","year":"2018","journal-title":"Expert Rev Med Devices"},{"key":"10.1016\/j.jfo.2025.104469_bib0060","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1007\/s10792-017-0571-x","article-title":"Minimally invasive combined glaucoma and cataract surgery: clinical results of the smallest ab interno gel stent","volume":"38","author":"De Gregorio","year":"2018","journal-title":"Int Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0065","article-title":"A comparison of iStent combined with phacoemulsification and endocyclophotocoagulation (ICE2) with the PreserFlo MicroShunt and XEN-45 implants","volume":"14","author":"Qidwai","year":"2022","journal-title":"Ther Adv Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0070","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.2147\/OPTH.S405821","article-title":"Long-term effectiveness of XEN 45 gel-stent in open-angle glaucoma patients","volume":"17","author":"Marcos-Parra","year":"2023","journal-title":"Clin Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0075","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1097\/IJG.0000000000002090","article-title":"3-year outcomes of XEN implant compared with trabeculectomy, with or without phacoemulsification for open angle glaucoma","volume":"31","author":"Marcos-Parra","year":"2022","journal-title":"J Glaucoma"},{"key":"10.1016\/j.jfo.2025.104469_bib0080","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1001\/archophthalmol.2011.329","article-title":"Cataract surgery after trabeculectomy: the effect on trabeculectomy function","volume":"130","author":"Husain","year":"2012","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0085","doi-asserted-by":"crossref","first-page":"3209","DOI":"10.1007\/s00417-021-05189-x","article-title":"Standalone XEN45 Gel Stent implantation versus combined XEN45-phacoemulsification in the treatment of open angle glaucoma-a systematic review and meta-analysis","volume":"259","author":"Lim","year":"2021","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0090","doi-asserted-by":"crossref","first-page":"1056","DOI":"10.1097\/IJG.0000000000001954","article-title":"Comparison of efficacy and safety of XEN45 implant versus trabeculectomy in Asian eyes","volume":"30","author":"Kee","year":"2021","journal-title":"J Glaucoma"},{"key":"10.1016\/j.jfo.2025.104469_bib0095","doi-asserted-by":"crossref","first-page":"769","DOI":"10.3341\/jkos.2022.63.9.769","article-title":"Short-term outcomes and prognostic factor of cataract combined surgery with iStent Inject versus XEN","volume":"63","author":"Ma","year":"2022","journal-title":"J Korean Ophthalmol Soc"},{"key":"10.1016\/j.jfo.2025.104469_bib0100","series-title":"Guidelines on design and reporting of glaucoma surgical trials","author":"Shaarawy","year":"2009"},{"key":"10.1016\/j.jfo.2025.104469_bib0105","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1007\/s40123-018-0152-8","article-title":"Prospective, non-randomized, 36-month study of second-generation trabecular micro-bypass stents with phacoemulsification in eyes with various types of glaucoma","volume":"7","author":"Hengerer","year":"2018","journal-title":"Ophthalmol Ther"},{"key":"10.1016\/j.jfo.2025.104469_bib0110","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40662-019-0169-7","article-title":"Second-generation trabecular micro-bypass stent implantation: Retrospective analysis after 12- and 24-month follow-up","volume":"7","author":"Neuhann","year":"2020","journal-title":"Eye Vis (Lond)"},{"key":"10.1016\/j.jfo.2025.104469_bib0115","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1007\/s00417-017-3895-3","article-title":"MIGS: therapeutic success of combined Xen Gel Stent implantation with cataract surgery","volume":"256","author":"Hohberger","year":"2018","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0120","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1007\/s00417-018-3899-7","article-title":"The XEN45 Gel Stent as a minimally invasive procedure in glaucoma surgery: success rates, risk profile, and rates of re-surgery after 261 surgeries","volume":"256","author":"Widder","year":"2018","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0125","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1097\/IJG.0000000000000858","article-title":"Prospective evaluation of standalone XEN gel implant and combined phacoemulsification-XEN gel implant surgery: 1-year results","volume":"27","author":"Mansouri","year":"2018","journal-title":"J Glaucoma"},{"key":"10.1016\/j.jfo.2025.104469_bib0130","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1177\/1120672118795063","article-title":"One-year follow-up of the XEN\u00ae implant with mitomycin-C in pseudoexfoliative glaucoma patients","volume":"29","author":"Ib\u00e1\u00f1ez-Mu\u00f1oz","year":"2019","journal-title":"Eur J Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0135","doi-asserted-by":"crossref","first-page":"5457246","DOI":"10.1155\/2017\/5457246","article-title":"XEN glaucoma implant with mitomycin C 1-year follow-up: result and complications","volume":"2017","author":"Galal","year":"2017","journal-title":"J Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0140","doi-asserted-by":"crossref","first-page":"1897","DOI":"10.2147\/OPTH.S412400","article-title":"Four-year outcome of XEN 45 gel stent implantation in a Swedish population","volume":"17","author":"Busch","year":"2023","journal-title":"Clin Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0145","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1038\/s41433-023-02642-5","article-title":"Effectiveness and safety of XEN45 implant over 12 months of follow-up: data from the XEN-Glaucoma Treatment Registry","volume":"38","author":"Oddone","year":"2024","journal-title":"Eye (Lond)"},{"key":"10.1016\/j.jfo.2025.104469_bib0150","doi-asserted-by":"crossref","first-page":"3507","DOI":"10.2147\/OPTH.S271646","article-title":"Two-year multicenter outcomes of iStent inject trabecular micro-bypass stents combined with phacoemulsification in various types of glaucoma and ocular hypertension","volume":"14","author":"Clement","year":"2020","journal-title":"Clin Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0155","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1007\/s40123-019-00214-z","article-title":"One-year outcomes of second-generation trabecular micro-bypass stents (iStent Inject) implantation with cataract surgery in different glaucoma subtypes and severities","volume":"8","author":"Salimi","year":"2019","journal-title":"Ophthalmol Ther"},{"issue":"2","key":"10.1016\/j.jfo.2025.104469_bib0160","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1177\/11206721211014381","article-title":"Efficacy and safety data for the Ab interno XEN45 gel stent implant at 3 years: a retrospective analysis","volume":"32","author":"Gabbay","year":"2021","journal-title":"Eur J Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0165","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1007\/s00417-019-04251-z","article-title":"Two-year results of a multicenter study of the ab interno gelatin implant in medically uncontrolled primary open-angle glaucoma","volume":"257","author":"Reitsamer","year":"2019","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0170","doi-asserted-by":"crossref","first-page":"e531","DOI":"10.1111\/aos.14605","article-title":"Combined and stand-alone XEN 45 gel stent implantation: 3-year outcomes and success predictors","volume":"99","author":"Gillmann","year":"2021","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0185","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1016\/j.jcrs.2014.01.032","article-title":"Ab interno approach to the subconjunctival space using a collagen glaucoma stent","volume":"40","author":"Lewis","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jfo.2025.104469_bib0190","doi-asserted-by":"crossref","first-page":"1741","DOI":"10.1007\/s00417-019-04341-y","article-title":"XEN implant device versus trabeculectomy, either alone or in combination with phacoemulsification, in open-angle glaucoma patients","volume":"257","author":"Marcos Parra","year":"2019","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"10.1016\/j.jfo.2025.104469_bib0175","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1016\/j.ophtha.2017.05.004","article-title":"Efficacy, safety, and risk factors for failure of standalone ab interno gelatin microstent implantation versus standalone trabeculectomy [published correction appears in Ophthalmology. 2018 Mar;125(3):463]","volume":"124","author":"Schlenker","year":"2017","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jfo.2025.104469_bib0180","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1038\/s41433-018-0243-8","article-title":"A multi-centre interventional case series of 259 ab-interno Xen gel implants for glaucoma, with and without combined cataract surgery","volume":"33","author":"Karimi","year":"2019","journal-title":"Eye (Lond)"}],"container-title":["Journal Fran\u00e7ais d'Ophtalmologie"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0181551225000518?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0181551225000518?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,4,11]],"date-time":"2025-04-11T16:33:51Z","timestamp":1744389231000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0181551225000518"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":38,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["S0181551225000518"],"URL":"https:\/\/doi.org\/10.1016\/j.jfo.2025.104469","relation":{},"ISSN":["0181-5512"],"issn-type":[{"value":"0181-5512","type":"print"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Real-world comparison of efficacy and safety of XEN45 implant with phacoemulsification versus iStent inject\u00ae W with phacoemulsification","name":"articletitle","label":"Article Title"},{"value":"Journal Fran\u00e7ais d'Ophtalmologie","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jfo.2025.104469","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier Masson SAS.","name":"copyright","label":"Copyright"}],"article-number":"104469"}}