{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T17:26:50Z","timestamp":1793899610764,"version":"4.8.0"},"reference-count":40,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,12,2]],"date-time":"2025-12-02T00:00:00Z","timestamp":1764633600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100006360","name":"Bundesministerium f\u00fcr Wirtschaft und Klimaschutz","doi-asserted-by":"publisher","award":["03ET1454A"],"award-info":[{"award-number":["03ET1454A"]}],"id":[{"id":"10.13039\/501100006360","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hazardous Materials"],"published-print":{"date-parts":[[2026,1]]},"DOI":"10.1016\/j.jhazmat.2025.140712","type":"journal-article","created":{"date-parts":[[2025,12,3]],"date-time":"2025-12-03T17:09:32Z","timestamp":1764781772000},"page":"140712","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Influence of a local ventilation system on patient and personnel protection in operating rooms"],"prefix":"10.1016","volume":"501","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1449-4315","authenticated-orcid":false,"given":"Lukas","family":"Schumann","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kimberly Samanta","family":"Hoerold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert Oliver","family":"Tomaschewski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0165-2900","authenticated-orcid":false,"given":"Yunus Emre","family":"Cetin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0107-6333","authenticated-orcid":false,"given":"Martin","family":"Kriegel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhazmat.2025.140712_bib1","series-title":"Global Guidelines for the Prevention of Surgical Site Infection","author":"World Health Organization","year":"2018"},{"key":"10.1016\/j.jhazmat.2025.140712_bib2","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.jhin.2019.11.007","article-title":"Genetic relationship between bacteria isolated from intraoperative air samples and surgical site infections at a major teaching hospital in Ghana","volume":"104","author":"Stauning","year":"2020","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhazmat.2025.140712_bib3","article-title":"A systematic review of operating room ventilation","volume":"40","author":"Sadrizadeh","year":"2021","journal-title":"J Build Eng"},{"key":"10.1016\/j.jhazmat.2025.140712_bib4","article-title":"Experimental evaluation of airborne spread of contaminations in operating room air under laminar air flow and mixing ventilation","volume":"113","author":"Schumann","year":"2025","journal-title":"J Build Eng"},{"key":"10.1016\/j.jhazmat.2025.140712_bib5","doi-asserted-by":"crossref","unstructured":"DIN 1946-4:2018-09, Raumlufttechnik_- Teil_4: Raumlufttechnische Anlagen in Geb\u00e4uden und R\u00e4umen des Gesundheitswesens. doi:10.31030\/2881775.","DOI":"10.31030\/2881775"},{"key":"10.1016\/j.jhazmat.2025.140712_bib6","doi-asserted-by":"crossref","unstructured":"DAVIES, R.R. & NOBLE, W.C. Dispersal of bacteria on desquamated skin. Lancet (London, England) 2, 1295\u20131297 (1962).","DOI":"10.1016\/S0140-6736(62)90849-8"},{"key":"10.1016\/j.jhazmat.2025.140712_bib7","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1111\/j.1749-6632.1980.tb18928.x","article-title":"Documentation of airborne infection during surgery","volume":"353","author":"Kundsin","year":"1980","journal-title":"Ann N Y Acad Sci"},{"key":"10.1016\/j.jhazmat.2025.140712_bib8","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1017\/ice.2016.240","article-title":"Association of airborne microorganisms in the operating room with implant infections: a randomized controlled trial","volume":"38","author":"Darouiche","year":"2017","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jhazmat.2025.140712_bib9","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.jhin.2020.04.010","article-title":"Operating room ventilation and the risk of revision due to infection after total hip arthroplasty: assessment of validated data in the Norwegian Arthroplasty Register","volume":"105","author":"Langvatn","year":"2020","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhazmat.2025.140712_bib10","first-page":"52","article-title":"Laminar airflow and the prevention of surgical site infection. More harm than good?","volume":"13","author":"McHugh","year":"2015","journal-title":"Surg J R Coll Surg Edinb Irel"},{"key":"10.1016\/j.jhazmat.2025.140712_bib11","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1016\/S1473-3099(17)30059-2","article-title":"Effect of laminar airflow ventilation on surgical site infections: a systematic review and meta-analysis","volume":"17","author":"Bischoff","year":"2017","journal-title":"Lancet Infect Dis"},{"key":"10.1016\/j.jhazmat.2025.140712_bib12","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1002\/aorn.13327","article-title":"The role of perioperative hypothermia in the development of surgical site infection: a systematic review","volume":"113","author":"\u00d6ner Cengiz","year":"2021","journal-title":"AORN J"},{"key":"10.1016\/j.jhazmat.2025.140712_bib13","doi-asserted-by":"crossref","DOI":"10.3390\/ijerph18168749","article-title":"Perioperative hypothermia-a narrative review","volume":"18","author":"Rauch","year":"2021","journal-title":"Int J Environ Res Public Health"},{"key":"10.1016\/j.jhazmat.2025.140712_bib14","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1016\/j.bpa.2008.06.004","article-title":"Physiology of thermoregulation","volume":"22","author":"Kurz","year":"2008","journal-title":"Best Pract Res Clin Anaesthesiol"},{"key":"10.1016\/j.jhazmat.2025.140712_bib15","doi-asserted-by":"crossref","first-page":"38","DOI":"10.5603\/AIT.2013.0009","article-title":"Inadvertent intraoperative hypothermia","volume":"45","author":"Horosz","year":"2013","journal-title":"Anaesthesiol Intensive Ther"},{"key":"10.1016\/j.jhazmat.2025.140712_bib16","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1097\/01.anes.0000296719.73450.52","article-title":"The effects of mild perioperative hypothermia on blood loss and transfusion requirement","volume":"108","author":"Rajagopalan","year":"2008","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jhazmat.2025.140712_bib17","first-page":"468","article-title":"Unintentional hypothermia is associated with postoperative myocardial ischemia","volume":"78","author":"Frank","year":"1993","journal-title":"Perioper Ischemia Random Anesth Trial Study Group Anesthesiol"},{"key":"10.1016\/j.jhazmat.2025.140712_bib18","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/j.ygyno.2013.08.034","article-title":"Intraoperative hypothermia during primary surgical cytoreduction for advanced ovarian cancer: risk factors and associations with postoperative morbidity","volume":"131","author":"Long","year":"2013","journal-title":"Gynecol Oncol"},{"key":"10.1016\/j.jhazmat.2025.140712_bib19","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.1046\/j.1365-2044.2003.03444.x","article-title":"Effect of postoperative skin-surface warming on oxygen consumption and the shivering threshold","volume":"58","author":"Alfonsi","year":"2003","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jhazmat.2025.140712_bib20","doi-asserted-by":"crossref","first-page":"1209","DOI":"10.1056\/NEJM199605093341901","article-title":"Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. Study of Wound Infection and Temperature Group","volume":"334","author":"Kurz","year":"1996","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jhazmat.2025.140712_bib21","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.jhin.2010.05.016","article-title":"Assessment of horizontal laminar air flow instrument table for additional ultraclean space during surgery","volume":"76","author":"Nilsson","year":"2010","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhazmat.2025.140712_bib22","doi-asserted-by":"crossref","DOI":"10.1016\/j.buildenv.2020.106643","article-title":"Conflicting effects of a portable ultra-clean airflow unit on the sterility of operating rooms: A numerical investigation","volume":"171","author":"Casagrande","year":"2020","journal-title":"Build Environ"},{"key":"10.1016\/j.jhazmat.2025.140712_bib23","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.jse.2020.08.035","article-title":"A localized laminar flow device decreases airborne particulates during shoulder arthroplasty: a randomized controlled trial","volume":"30","author":"Morris","year":"2021","journal-title":"J Shoulder Elb Surg"},{"key":"10.1016\/j.jhazmat.2025.140712_bib24","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1007\/s10195-011-0168-5","article-title":"Mobile laminar air flow screen for additional operating room ventilation: reduction of intraoperative bacterial contamination during total knee arthroplasty","volume":"12","author":"Sossai","year":"2011","journal-title":"J Orthop Trauma J Ital Soc Orthop Trauma"},{"key":"10.1016\/j.jhazmat.2025.140712_bib25","doi-asserted-by":"crossref","DOI":"10.1016\/j.buildenv.2020.107038","article-title":"Investigating the influences of ventilation on the fate of particles generated by patient and medical staff in operating room","volume":"180","author":"Li","year":"2020","journal-title":"Build Environ"},{"key":"10.1016\/j.jhazmat.2025.140712_bib26","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.jhin.2018.03.024","article-title":"Effect of mobile laminar airflow units on airborne bacterial contamination during neurosurgical procedures","volume":"99","author":"von Vogelsang","year":"2018","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhazmat.2025.140712_bib27","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1080\/15459624.2017.1422082","article-title":"Surgical smoke control with local exhaust ventilation: Experimental study","volume":"15","author":"Lee","year":"2018","journal-title":"J Occup Environ Hyg"},{"key":"10.1016\/j.jhazmat.2025.140712_bib28","doi-asserted-by":"crossref","first-page":"06081","DOI":"10.1051\/e3sconf\/201911106081","article-title":"Local and general ventilation system for an operating room with surgeons and patient","volume":"111","author":"Tacutu","year":"2019","journal-title":"E3S Web Conf"},{"key":"10.1016\/j.jhazmat.2025.140712_bib29","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/j.partic.2014.06.002","article-title":"Effect of a portable ultra-clean exponential airflow unit on the particle distribution in an operating room","volume":"18","author":"Sadrizadeh","year":"2015","journal-title":"Particuology"},{"key":"10.1016\/j.jhazmat.2025.140712_bib30","article-title":"Thermal comfort in operating rooms with laminar airflow systems and turbulent mixing ventilation","author":"Hartmann","year":"2019","journal-title":"Int. J. Geogr. Inf. Sci."},{"key":"10.1016\/j.jhazmat.2025.140712_bib31","doi-asserted-by":"crossref","DOI":"10.1111\/ina.12947","article-title":"Exposure of operating room surgical staff to surgical smoke under different ventilation schemes","volume":"32","author":"Hofer","year":"2022","journal-title":"Indoor air"},{"key":"10.1016\/j.jhazmat.2025.140712_bib32","author":"Nilsson","year":"2007","journal-title":"Benchmark Test a Comput Simula Pers Manikin Heat Loss Therm Comf Eval"},{"key":"10.1016\/j.jhazmat.2025.140712_bib33","first-page":"358","article-title":"Experimental investigation of the spread of airborne CFU in a research-OR under different air flow regimes using tracer particles","author":"Schumann","year":"2021","journal-title":"Healthy Build 2021 Eur Proc 17th Int Healthy Build Conf 2021"},{"key":"10.1016\/j.jhazmat.2025.140712_bib34","doi-asserted-by":"crossref","first-page":"05072","DOI":"10.1051\/e3sconf\/202235605072","article-title":"Investigation of methods regarding the effectiveness of ventilation strategies in an operating room on the removal of airborne germs using tracer particles","volume":"356","author":"Schumann","year":"2022","journal-title":"E3S Web Conf"},{"key":"10.1016\/j.jhazmat.2025.140712_bib35","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jhin.2005.01.014","article-title":"Surgical smoke and infection control","volume":"62","author":"Alp","year":"2006","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhazmat.2025.140712_bib36","author":"DIN EN ISO 7730:2006-05","year":"2006","journal-title":"Ergon Therm Environ Anal Determ Interpret Therm Comf Using Calc PMV PPD Indices Local Therm Comf Criteria"},{"key":"10.1016\/j.jhazmat.2025.140712_bib37","doi-asserted-by":"crossref","unstructured":"Physiologie: \u2026 68 Tabellen . (Thieme, Stuttgart, 2005). doi:10.1055\/b-002-46974.","DOI":"10.1055\/b-002-46974"},{"key":"10.1016\/j.jhazmat.2025.140712_bib38","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1080\/10789669.2013.838438","article-title":"Thermal comfort and local discomfort in an operating room ventilated with spiral diffuser jet","volume":"19","author":"Vilain","year":"2013","journal-title":"HVACR Res"},{"key":"10.1016\/j.jhazmat.2025.140712_bib39","series-title":"in IAQVEC 2016 - Proceedings of 9th International Conference on Indoor Air Quality Ventilation & Energy Conservation in Buildings","article-title":"The effects of the thermal environment on occupants responses in health care facilities: A literature review","author":"Salonen","year":"2016"},{"key":"10.1016\/j.jhazmat.2025.140712_bib40","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1016\/j.ajic.2018.03.005","article-title":"Door openings in the operating room are associated with increased environmental contamination","volume":"46","author":"Perez","year":"2018","journal-title":"Am J Infect Control"}],"container-title":["Journal of Hazardous Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0304389425036325?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0304389425036325?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T16:50:15Z","timestamp":1793897415000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0304389425036325"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":40,"alternative-id":["S0304389425036325"],"URL":"https:\/\/doi.org\/10.1016\/j.jhazmat.2025.140712","relation":{},"ISSN":["0304-3894"],"issn-type":[{"value":"0304-3894","type":"print"}],"subject":[],"published":{"date-parts":[[2026,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Influence of a local ventilation system on patient and personnel protection in operating rooms","name":"articletitle","label":"Article Title"},{"value":"Journal of Hazardous Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhazmat.2025.140712","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"140712"}}