{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T10:51:14Z","timestamp":1792839074276,"version":"4.5.0"},"reference-count":29,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,9,24]],"date-time":"2020-09-24T00:00:00Z","timestamp":1600905600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"Stiftung f\u00fcr Leberkrankheiten"},{"DOI":"10.13039\/501100004587","name":"Instituto de Salud Carlos III","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004587","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Ministry of Health, Spain"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal-of-hepatology.eu","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hepatology"],"published-print":{"date-parts":[[2021,1]]},"DOI":"10.1016\/j.jhep.2020.09.018","type":"journal-article","created":{"date-parts":[[2020,9,26]],"date-time":"2020-09-26T00:33:00Z","timestamp":1601080380000},"page":"230-234","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":63,"title":["Small diameter shunts should lead to safe expansion of the use of TIPS"],"prefix":"10.1016","volume":"74","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3414-0055","authenticated-orcid":false,"given":"Jaume","family":"Bosch","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhep.2020.09.018_bib1","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1056\/NEJMra0901512","article-title":"Management of varices and variceal hemorrhage in cirrhosis","volume":"362","author":"Garcia-Tsao","year":"2010","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jhep.2020.09.018_bib2","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/j.jhep.2015.05.022","article-title":"Expanding consensus in portal hypertension: report of the Baveno VI Consensus Workshop: stratifying risk and individualizing care for portal hypertension","volume":"63","author":"de Franchis","year":"2015","journal-title":"J\u00a0Hepatol"},{"key":"10.1016\/j.jhep.2020.09.018_bib3","doi-asserted-by":"crossref","first-page":"100122","DOI":"10.1016\/j.jhepr.2020.100122","article-title":"Where does TIPS fit in the management of patients with cirrhosis?","volume":"2","author":"Garcia-Pagan","year":"2020","journal-title":"JHEP Rep"},{"key":"10.1016\/j.jhep.2020.09.018_bib4","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1097\/00000658-198610000-00003","article-title":"A\u00a0systematic appraisal of portacaval H-graft diameters. Clinical and hemodynamic perspectives","volume":"204","author":"Sarfeh","year":"1986","journal-title":"Ann Surg"},{"key":"10.1016\/j.jhep.2020.09.018_bib5","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1007\/s11605-006-0056-0","article-title":"Survival and variceal rehemorrhage after shunting support small-diameter prosthetic H-graft portacaval shunt","volume":"11","author":"Rosemurgy","year":"2007","journal-title":"J\u00a0Gastrointest Surg"},{"key":"10.1016\/j.jhep.2020.09.018_bib6","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1097\/00000658-198304000-00008","article-title":"Portacaval H-graft: relationships of shunt diameter, portal flow patterns and encephalopathy","volume":"197","author":"Sarfeh","year":"1983","journal-title":"Ann Surg"},{"key":"10.1016\/j.jhep.2020.09.018_bib7","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/S1091-255X(98)80061-9","article-title":"Small-diameter prosthetic H-graft portacaval shunt: definitive therapy for variceal bleeding","volume":"2","author":"Rosemurgy","year":"1998","journal-title":"J\u00a0Gastrointest Surg"},{"key":"10.1016\/j.jhep.2020.09.018_bib8","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1016\/0002-9610(71)90147-4","article-title":"Transjugular intrahepatic portacaval shunt. An experimental work","volume":"121","author":"Rosch","year":"1971","journal-title":"Am J Surg"},{"key":"10.1016\/j.jhep.2020.09.018_bib9","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1056\/NEJM199401203300303","article-title":"The transjugular intrahepatic portosystemic stent-shunt procedure for variceal bleeding","volume":"330","author":"Rossle","year":"1994","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jhep.2020.09.018_bib10","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1053\/j.gastro.2003.11.016","article-title":"Improved clinical outcome using polytetrafluoroethylene-coated stents for TIPS: results of a randomized study","volume":"126","author":"Bureau","year":"2004","journal-title":"Gastroenterology"},{"key":"10.1016\/j.jhep.2020.09.018_bib11","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1016\/S0016-5085(98)70436-6","article-title":"Clinical events after transjugular intrahepatic portosystemic shunt: correlation with hemodynamic findings","volume":"114","author":"Casado","year":"1998","journal-title":"Gastroenterology"},{"key":"10.1016\/j.jhep.2020.09.018_bib12","doi-asserted-by":"crossref","first-page":"1197","DOI":"10.1002\/hep.20436","article-title":"PTFE-covered stents improve TIPS patency in Budd-Chiari syndrome","volume":"40","author":"Hernandez-Guerra","year":"2004","journal-title":"Hepatology"},{"key":"10.1016\/j.jhep.2020.09.018_bib13","doi-asserted-by":"crossref","first-page":"2108","DOI":"10.1002\/hep.23612","article-title":"Right atrial pressure is not adequate to calculate portal pressure gradient in cirrhosis: a clinical-hemodynamic correlation study","volume":"51","author":"La Mura","year":"2010","journal-title":"Hepatology"},{"key":"10.1016\/j.jhep.2020.09.018_bib14","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1111\/liv.12229","article-title":"Impact of deep sedation on the accuracy of hepatic and portal venous pressure measurements in patients with cirrhosis","volume":"34","author":"Reverter","year":"2014","journal-title":"Liver Int"},{"key":"10.1016\/j.jhep.2020.09.018_bib15","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1053\/j.gastro.2017.01.011","article-title":"Timing affects measurement of portal pressure gradient after placement of transjugular intrahepatic portosystemic shunts in patients with portal hypertension","volume":"152","author":"Silva-Junior","year":"2017","journal-title":"Gastroenterology"},{"key":"10.1016\/j.jhep.2020.09.018_bib16","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1007\/s00270-017-1807-x","article-title":"Transjugular intrahepatic portosystemic shunt reduction using the GORE VIATORR controlled expansion endoprosthesis: Hemodynamics of reducing an established 10-mm TIPS to 8-mm in diameter","volume":"41","author":"Srinivasa","year":"2018","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jhep.2020.09.018_bib17","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1038\/nrgastro.2009.149","article-title":"The clinical use of HVPG measurements in chronic liver disease","volume":"6","author":"Bosch","year":"2009","journal-title":"Nat Rev Gastroenterol Hepatol"},{"key":"10.1016\/j.jhep.2020.09.018_bib18","doi-asserted-by":"crossref","first-page":"2793","DOI":"10.1016\/j.cgh.2019.03.042","article-title":"Smaller-diameter covered transjugular intrahepatic portosystemic shunt stents are associated with increased survival","volume":"17","author":"Trebicka","year":"2019","journal-title":"Clin Gastroenterol Hepatol"},{"key":"10.1016\/j.jhep.2020.09.018_bib19","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.jvir.2016.06.023","article-title":"Prospective evaluation of passive expansion of partially dilated transjugular intrahepatic portosystemic shunt stent grafts-a three-dimensional sonography study","volume":"28","author":"Pieper","year":"2017","journal-title":"J\u00a0Vasc Interv Radiol"},{"key":"10.1016\/j.jhep.2020.09.018_bib20","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1007\/s00270-018-2040-y","article-title":"Transjugular intrahepatic portosystemic shunt using the new gore viatorr controlled expansion endoprosthesis: prospective, single-center, preliminary experience","volume":"42","author":"Miraglia","year":"2019","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jhep.2020.09.018_bib21","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.jhep.2017.05.006","article-title":"Eight millimetre covered TIPS does not compromise shunt function but reduces hepatic encephalopathy in preventing variceal rebleeding","volume":"67","author":"Wang","year":"2017","journal-title":"J\u00a0Hepatol"},{"key":"10.1016\/j.jhep.2020.09.018_bib22","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1016\/j.cgh.2018.01.029","article-title":"Under-dilated TIPS associate with efficacy and reduced encephalopathy in a prospective, non-randomized study of patients with cirrhosis","volume":"16","author":"Schepis","year":"2018","journal-title":"Clin Gastroenterol Hepatol"},{"key":"10.1016\/j.jhep.2020.09.018_bib23","doi-asserted-by":"crossref","first-page":"438","DOI":"10.2214\/AJR.17.18222","article-title":"Incrementally expandable transjugular intrahepatic portosystemic shunts: single-center experience","volume":"210","author":"Cui","year":"2018","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.jhep.2020.09.018_bib24","doi-asserted-by":"crossref","first-page":"1928","DOI":"10.1002\/hep.30934","article-title":"A\u00a0prospective study identifying predictive factors of cardiac decompensation after transjugular intrahepatic portosystemic shunt: the Toulouse algorithm","volume":"70","author":"Billey","year":"2019","journal-title":"Hepatology"},{"key":"10.1016\/j.jhep.2020.09.018_bib25","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1016\/j.jhep.2018.03.024","article-title":"EASL clinical practice guidelines for the management of patients with decompensated cirrhosis","volume":"69","year":"2018","journal-title":"J\u00a0Hepatol"},{"key":"10.1016\/j.jhep.2020.09.018_bib26","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1136\/gut.52.1.130","article-title":"Acute propranolol administration effectively decreases portal pressure in patients with TIPS dysfunction. Transjugular intrahepatic portosystemic shunt","volume":"52","author":"Bellis","year":"2003","journal-title":"Gut"},{"key":"10.1016\/j.jhep.2020.09.018_bib27","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1007\/s002709900118","article-title":"Embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy","volume":"20","author":"Sakurabayashi","year":"1997","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.jhep.2020.09.018_bib28","first-page":"10A","article-title":"Rifaximin for the prevention of hepatic encephalopathy in patients treated by TIPS: a multicentric randomized placebo-controlled trial","volume":"70","author":"Bureau","year":"2019","journal-title":"Hepatology"},{"key":"10.1016\/j.jhep.2020.09.018_bib29","doi-asserted-by":"crossref","first-page":"2757","DOI":"10.1007\/s10620-019-05615-5","article-title":"Management of thrombocytopenia in patients with chronic liver disease","volume":"64","author":"Saab","year":"2019","journal-title":"Dig Dis Sci"}],"container-title":["Journal of Hepatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S016882782033662X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S016882782033662X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T19:41:58Z","timestamp":1759174918000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S016882782033662X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["S016882782033662X"],"URL":"https:\/\/doi.org\/10.1016\/j.jhep.2020.09.018","relation":{},"ISSN":["0168-8278"],"issn-type":[{"value":"0168-8278","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Small diameter shunts should lead to safe expansion of the use of TIPS","name":"articletitle","label":"Article Title"},{"value":"Journal of Hepatology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhep.2020.09.018","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 European Association for the Study of the Liver. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}