{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T13:53:26Z","timestamp":1790085206677,"version":"4.0.1"},"reference-count":25,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2016,5,1]],"date-time":"2016-05-01T00:00:00Z","timestamp":1462060800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","journalofhospitalinfection.com","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hospital Infection"],"published-print":{"date-parts":[[2016,5]]},"DOI":"10.1016\/j.jhin.2016.01.016","type":"journal-article","created":{"date-parts":[[2016,2,9]],"date-time":"2016-02-09T01:03:15Z","timestamp":1454979795000},"page":"70-77","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":57,"title":["Efficacy of two hydrogen peroxide vapour aerial decontamination systems for enhanced disinfection of meticillin-resistant Staphylococcus aureus, Klebsiella pneumoniae and Clostridium difficile in single isolation rooms"],"prefix":"10.1016","volume":"93","author":[{"given":"S.","family":"Ali","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Muzslay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Bruce","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Jeanes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Moore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.P.R.","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhin.2016.01.016_bib1","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.jhin.2009.03.030","article-title":"The role of environmental cleaning in the control of hospital-acquired infection","volume":"73","author":"Dancer","year":"2009","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2016.01.016_bib2","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1097\/CCM.0b013e318206bc66","article-title":"The impact of enhanced cleaning within the intensive care unit on contamination of the near-patient environment with hospital pathogens: a randomized crossover study in critical care units in two hospitals","volume":"39","author":"Wilson","year":"2011","journal-title":"Crit Care Med"},{"key":"10.1016\/j.jhin.2016.01.016_bib3","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1086\/657944","article-title":"Contamination of hands with methicillin-resistant Staphylococcus aureus after contact with environmental surfaces and after contact with the skin of colonized patients","volume":"32","author":"Steifel","year":"2011","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jhin.2016.01.016_bib4","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1128\/JCM.38.2.724-726.2000","article-title":"Survival of enterococci and staphylococci on hospital fabrics and plastics","volume":"38","author":"Neely","year":"2000","journal-title":"J\u00a0Clin Microbiol"},{"key":"10.1016\/j.jhin.2016.01.016_bib5","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1186\/1471-2334-6-130","article-title":"How long do nosocomial pathogens persist on inanimate surfaces? A systematic review","volume":"6","author":"Kramer","year":"2006","journal-title":"BMC Infect Dis"},{"key":"10.1016\/j.jhin.2016.01.016_bib6","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1093\/infdis\/143.1.42","article-title":"Isolation of Clostridium difficile from the environment and contacts of patients with antibiotic-associated colitis","volume":"143","author":"Kim","year":"1981","journal-title":"J\u00a0Infect Dis"},{"key":"10.1016\/j.jhin.2016.01.016_bib7","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1001\/archinte.159.8.821","article-title":"Bacterial contamination of hands of hospital staff during routine patient care","volume":"159","author":"Pittet","year":"1999","journal-title":"Arch Intern Med"},{"key":"10.1016\/j.jhin.2016.01.016_bib8","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1086\/502369","article-title":"Acquisition of nosocomial pathogens on hands after contact with environmental surfaces near hospitalised patients","volume":"25","author":"Bhalla","year":"2004","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jhin.2016.01.016_bib9","doi-asserted-by":"crossref","first-page":"622","DOI":"10.2307\/30141488","article-title":"Environmental contamination due to methicillin-resistant Staphylococcus aureus: possible infection control implications","volume":"18","author":"Boyce","year":"1997","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jhin.2016.01.016_bib10","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1086\/524331","article-title":"Risk of glove or hand contamination after contact with patients colonized with vancomycin-resistant enterococcus or the colonized patients' environment","volume":"29","author":"Hayden","year":"2008","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jhin.2016.01.016_bib11","doi-asserted-by":"crossref","first-page":"1945","DOI":"10.1001\/archinte.166.18.1945","article-title":"Risk of acquiring antibiotic-resistant bacteria from prior room occupants","volume":"166","author":"Huang","year":"2006","journal-title":"Arch Intern Med"},{"key":"10.1016\/j.jhin.2016.01.016_bib12","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1056\/NEJMoa1216064","article-title":"Diverse sources of C.\u00a0difficile infection identified on whole-genome sequencing","volume":"369","author":"Eyre","year":"2013","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jhin.2016.01.016_bib13","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1111\/j.1472-765X.2008.02369.x","article-title":"The efficacy of the inorganic copper-based biocide CuWB50 is compromised by hard water","volume":"46","author":"Moore","year":"2008","journal-title":"Lett Appl Microbiol"},{"key":"10.1016\/j.jhin.2016.01.016_bib14","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.jhin.2011.06.010","article-title":"The spread and persistence of Clostridium difficile spores during and after cleaning with sporicidal disinfectants","volume":"79","author":"Ali","year":"2011","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2016.01.016_bib15","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1128\/CMR.12.1.147","article-title":"Antiseptics and disinfectant: activity, action and resistance","volume":"12","author":"McDonnell","year":"1999","journal-title":"Clin Microbiol Rev"},{"key":"10.1016\/j.jhin.2016.01.016_bib16","series-title":"Disinfection, sterilisation and preservation","first-page":"167","article-title":"Peroxygen compounds","author":"Block","year":"1991"},{"key":"10.1016\/j.jhin.2016.01.016_bib17","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1086\/589906","article-title":"Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in healthcare setting","volume":"29","author":"Boyce","year":"2008","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jhin.2016.01.016_bib18","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.jhin.2011.11.019","article-title":"Efficacy, efficiency and safety aspects of hydrogen peroxide vapour and aerosolized hydrogen peroxide room disinfection systems","volume":"80","author":"Fu","year":"2012","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2016.01.016_bib19","doi-asserted-by":"crossref","first-page":"2570","DOI":"10.1128\/JCM.00376-15","article-title":"A\u00a0novel quantitative sampling technique for the detection and monitoring of C.\u00a0difficile contamination in the clinical environment","volume":"53","author":"Ali","year":"2015","journal-title":"J\u00a0Clin Microbiol"},{"key":"10.1016\/j.jhin.2016.01.016_bib20","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/j.ajic.2005.04.240","article-title":"Activity of selected oxidising microbiocides against the spores of Clostridium difficile: relevance to environmental control","volume":"33","author":"Perez","year":"2005","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2016.01.016_bib21","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.ajic.2012.06.014","article-title":"Implementation of hospital-wide enhanced terminal cleaning of targeted patient rooms and its impact on endemic Clostridium difficile infection rates","volume":"41","author":"Manian","year":"2013","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2016.01.016_bib22","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/j.jhin.2010.12.013","article-title":"Impact of environmental decontamination using hydrogen peroxide vapour on the incidence of Clostridium difficile infection in one hospital trust","volume":"78","author":"Cooper","year":"2011","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2016.01.016_bib23","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.jhin.2012.06.014","article-title":"Clinical and cost effectiveness of eight disinfection methods for terminal disinfection of hospital isolation rooms contaminated with Clostridium difficile 027","volume":"82","author":"Doan","year":"2012","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2016.01.016_bib24","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.jhin.2011.11.001","article-title":"Meticillin-resistant Staphylococcus aureus is more resistant to vaporized hydrogen peroxide than commercial Geobacillus stearothermophillus biological indicators","volume":"80","author":"Pottage","year":"2012","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2016.01.016_bib25","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1016\/j.jhin.2012.08.022","article-title":"The elephant in the room: on the routine use of hydrogen peroxide vapour decontamination systems in health care","volume":"83","author":"Malik","year":"2013","journal-title":"J\u00a0Hosp Infect"}],"container-title":["Journal of Hospital Infection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670116000839?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670116000839?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,9,15]],"date-time":"2020-09-15T04:02:12Z","timestamp":1600142532000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0195670116000839"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,5]]}},"alternative-id":["S0195670116000839"],"URL":"https:\/\/doi.org\/10.1016\/j.jhin.2016.01.016","relation":{},"ISSN":["0195-6701"],"issn-type":[{"value":"0195-6701","type":"print"}],"subject":[],"published":{"date-parts":[[2016,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Efficacy of two hydrogen peroxide vapour aerial decontamination systems for enhanced disinfection of meticillin-resistant Staphylococcus aureus, Klebsiella pneumoniae and Clostridium difficile in single isolation rooms","name":"articletitle","label":"Article Title"},{"value":"Journal of Hospital Infection","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhin.2016.01.016","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2016 Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}]}}