{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T00:59:08Z","timestamp":1773622748526,"version":"3.50.1"},"reference-count":55,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2020,12,1]],"date-time":"2020-12-01T00:00:00Z","timestamp":1606780800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,12,1]],"date-time":"2020-12-01T00:00:00Z","timestamp":1606780800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100000739","name":"University of Southampton","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000739","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journalofhospitalinfection.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hospital Infection"],"published-print":{"date-parts":[[2020,12]]},"DOI":"10.1016\/j.jhin.2020.09.021","type":"journal-article","created":{"date-parts":[[2020,9,18]],"date-time":"2020-09-18T22:52:40Z","timestamp":1600469560000},"page":"649-656","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"title":["A cold water, ultrasonically activated stream efficiently removes proteins and prion-associated amyloid from surgical stainless steel"],"prefix":"10.1016","volume":"106","author":[{"given":"T.J.","family":"Secker","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.G.","family":"Leighton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.G.","family":"Offin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.R.","family":"Birkin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.C.","family":"Herv\u00e9","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.W.","family":"Keevil","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhin.2020.09.021_bib1","series-title":"Minimise transmission risk of CJD and vCJD in healthcare settings","author":"Bryant","year":"2015"},{"key":"10.1016\/j.jhin.2020.09.021_bib2","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1136\/jnnp.57.6.757","article-title":"Transmission of Creutzfeldt\u2013Jakob disease to a chimpanzee by electrodes contaminated during neurosurgery","volume":"57","author":"Gibbs","year":"1994","journal-title":"J\u00a0Neurol Neurosurg Psychiatry"},{"key":"10.1016\/j.jhin.2020.09.021_bib3","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.jhin.2010.01.024","article-title":"Current risk of iatrogenic Creutzfeld\u2013Jakob disease in the UK: efficacy of available cleaning chemistries and reusability of neurosurgical instruments","volume":"75","author":"Herv\u00e9","year":"2010","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib4","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.jhin.2006.05.011","article-title":"Diathermy forceps and pencils: reservoirs for protein and prion contamination?","volume":"64","author":"Lipscomb","year":"2006","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib5","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1016\/j.jhin.2006.02.015","article-title":"Surface decontamination of surgical instruments: an ongoing dilemma","volume":"63","author":"Murdoch","year":"2006","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib6","doi-asserted-by":"crossref","first-page":"3479","DOI":"10.1073\/pnas.0813342106","article-title":"Highly sensitive, quantitative cell-based assay for prions adsorbed to solid surfaces","volume":"106","author":"Edgeworth","year":"2009","journal-title":"Proc Natl Acad Sci USA"},{"key":"10.1016\/j.jhin.2020.09.021_bib7","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.mimet.2007.06.005","article-title":"Investigations of a prion infectivity assay to evaluate methods of decontamination","volume":"70","author":"Fichet","year":"2007","journal-title":"J\u00a0Microbiol Methods"},{"key":"10.1016\/j.jhin.2020.09.021_bib8","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1007\/BF03401958","article-title":"Transmission of scrapie by steel-surface-bound prions","volume":"7","author":"Flechsig","year":"2001","journal-title":"Mol Med"},{"key":"10.1016\/j.jhin.2020.09.021_bib9","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1086\/502392","article-title":"Infectivity of prion protein bound to stainless steel wires: a model for testing decontamination procedures for transmissible spongiform encephalopathies","volume":"25","author":"Yan","year":"2004","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jhin.2020.09.021_bib10","doi-asserted-by":"crossref","DOI":"10.1136\/bmj.f5675","article-title":"Prevalent abnormal prion protein in human appendixes after bovine spongiform encephalopathy epizootic: large scale survey","volume":"347","author":"Gill","year":"2013","journal-title":"BMJ"},{"key":"10.1016\/j.jhin.2020.09.021_bib11","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1016\/S0140-6736(10)62308-2","article-title":"Detection of prion infection in variant Creutzfeldt\u2013Jakob disease: a blood-based assay","volume":"377","author":"Edgeworth","year":"2011","journal-title":"Lancet"},{"key":"10.1016\/j.jhin.2020.09.021_bib12","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1111\/j.1423-0410.2006.00833.x","article-title":"Creutzfeldt\u2013Jakob disease and blood transfusion: results of the UK Transfusion Medicine Epidemiological Review study","volume":"91","author":"Hewitt","year":"2006","journal-title":"Vox Sang"},{"key":"10.1016\/j.jhin.2020.09.021_bib13","doi-asserted-by":"crossref","first-page":"2061","DOI":"10.1016\/S0140-6736(06)69835-8","article-title":"Clinical presentation and pre-mortem diagnosis of variant Creutzfeldt\u2013Jakob disease associated with blood transfusion: a case report","volume":"368","author":"Wroe","year":"2006","journal-title":"Lancet"},{"key":"10.1016\/j.jhin.2020.09.021_bib14","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1002\/jbm.b.30125","article-title":"Effects on instruments of the World Health Organization-recommended protocols for decontamination after possible exposure to transmissible spongiform encephalopathy-contaminated tissue","volume":"72B","author":"Brown","year":"2005","journal-title":"J\u00a0Biomed Mater Res"},{"key":"10.1016\/j.jhin.2020.09.021_bib15","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.jhin.2008.12.007","article-title":"Decontamination of prion protein (BSE301V) using a genetically engineered protease","volume":"72","author":"Dickinson","year":"2009","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib16","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1099\/vir.0.027201-0","article-title":"A\u00a0standardized comparison of commercially available prion decontamination reagents using the Standard Steel-Binding Assay","volume":"92","author":"Edgeworth","year":"2011","journal-title":"J\u00a0Gen Virol"},{"key":"10.1016\/j.jhin.2020.09.021_bib17","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.jhin.2007.08.020","article-title":"Prion inactivation using a new gaseous hydrogen peroxide sterilisation process","volume":"67","author":"Fichet","year":"2007","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib18","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1099\/vir.0.83396-0","article-title":"Decontamination of surgical instruments from prions. II. In\u00a0vivo findings with a model system for testing the removal of scrapie infectivity from steel surfaces","volume":"89","author":"Lemmer","year":"2008","journal-title":"J\u00a0Gen Virol"},{"key":"10.1016\/j.jhin.2020.09.021_bib19","doi-asserted-by":"crossref","first-page":"1152","DOI":"10.1086\/374668","article-title":"The challenge of prion decontamination","volume":"36","author":"McDonnell","year":"2003","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.jhin.2020.09.021_bib20","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.jhin.2008.09.015","article-title":"Photocatalytic degradation of prions using the photo-Fenton reagent","volume":"71","author":"Paspaltsis","year":"2009","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib21","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1080\/08927014.2012.698387","article-title":"Doped diamond-like carbon coatings for surgical instruments reduce protein and prion-amyloid biofouling and improve subsequent cleaning","volume":"28","author":"Secker","year":"2012","journal-title":"Biofouling"},{"key":"10.1016\/j.jhin.2020.09.021_bib22","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/S0195-6701(07)60007-3","article-title":"Halting the spread of human prion disease \u2013 exceptional measures for an exceptional problem","volume":"2","author":"Stephenson","year":"2007","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib23","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.jhin.2009.12.023","article-title":"Application of a fluorescent dual stain to assess decontamination of tissue protein and prion amyloid from surgical stainless steel during simulated washer\u2013disinfector cycles","volume":"75","author":"Howlin","year":"2010","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib24","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jhin.2006.09.025","article-title":"Effect of drying time, ambient temperature and pre-soaks on prion-infected tissue contamination levels on surgical stainless steel: concerns over prolonged transportation of instruments from theatre to central sterile service departments","volume":"65","author":"Lipscomb","year":"2007","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib25","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.jhin.2011.03.021","article-title":"Adsorption of prion and tissue proteins to surgical stainless steel surfaces and the efficacy of decontamination following dry and wet storage conditions","volume":"78","author":"Secker","year":"2011","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib26","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1080\/08927014.2015.1067686","article-title":"Efficacy of humidity retention bags for the reduced adsorption and improved cleaning of tissue proteins including prion-associated amyloid to surgical stainless steel surfaces","volume":"31","author":"Secker","year":"2015","journal-title":"Biofouling"},{"key":"10.1016\/j.jhin.2020.09.021_bib27","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.jhin.2009.07.023","article-title":"Quantitative measurement of the efficacy of protein removal by cleaning formulations; comparative evaluation of prion-directed cleaning chemistries","volume":"74","author":"Ungurs","year":"2010","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib28","doi-asserted-by":"crossref","DOI":"10.1121\/1.4799209","article-title":"A\u00a0new approach to ultrasonic cleaning","volume":"19","author":"Leighton","year":"2013","journal-title":"Proc Meet Acoust"},{"key":"10.1016\/j.jhin.2020.09.021_bib29","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1017\/jfm.2011.85","article-title":"The collapse of single bubbles and approximation of the far-field acoustic emissions for cavitation induced by shock wave lithotripsy","volume":"677","author":"Jamaluddin","year":"2011","journal-title":"J\u00a0Fluid Mech"},{"key":"10.1016\/j.jhin.2020.09.021_bib30","first-page":"20120538","article-title":"Prediction of far-field acoustic emissions from cavitation clouds during shock wave lithotripsy for development of a clinical device","volume":"469","author":"Leighton","year":"2013","journal-title":"Proc R Soc Lond A"},{"key":"10.1016\/j.jhin.2020.09.021_bib31","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/0041-624X(64)90224-0","article-title":"The measurement of cavitation","volume":"2","author":"Crawford","year":"1964","journal-title":"Ultrasonics"},{"key":"10.1016\/j.jhin.2020.09.021_bib32","series-title":"Bubble and particle dynamics in acoustic fields: modern trends and applications","first-page":"37","article-title":"Characterisation of measures of reference acoustic cavitation (COMORAC): an experimental feasibility trial","author":"Leighton","year":"2005"},{"key":"10.1016\/j.jhin.2020.09.021_bib33","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1016\/j.ultsonch.2015.05.004","article-title":"Ultrasonic cleaning: an historical perspective","volume":"29","author":"Mason","year":"2016","journal-title":"Ultrason Sonochem"},{"key":"10.1016\/j.jhin.2020.09.021_bib34","article-title":"Measurement of cavitation activity in ultrasonic cleaners","volume":"6","author":"Boucher","year":"1967","journal-title":"Contam Control"},{"key":"10.1016\/j.jhin.2020.09.021_bib35","article-title":"Bubble acoustics: from whales to other worlds","volume":"36","author":"Leighton","year":"2014","journal-title":"Proc Inst Acoustics"},{"key":"10.1016\/j.jhin.2020.09.021_bib36","first-page":"322","article-title":"Transient processes near the threshold of acoustically driven bubble shape oscillations","volume":"87","author":"Maksimov","year":"2001","journal-title":"Acta Acoustica"},{"key":"10.1016\/j.jhin.2020.09.021_bib37","article-title":"The acoustic bubble: oceanic bubble acoustics and ultrasonic cleaning","volume":"24","author":"Leighton","year":"2017","journal-title":"Proc Meet Acoustics"},{"key":"10.1016\/j.jhin.2020.09.021_bib38","doi-asserted-by":"crossref","first-page":"21709","DOI":"10.1039\/C5CP02933C","article-title":"Electrochemical \u2018bubble swarm\u2019 enhancement of ultrasonic surface cleaning","volume":"17","author":"Birkin","year":"2015","journal-title":"Phys Chem Chem Phys"},{"key":"10.1016\/j.jhin.2020.09.021_bib39","doi-asserted-by":"crossref","first-page":"20574","DOI":"10.1039\/C5CP02406D","article-title":"Cold water cleaning of brain proteins, biofilm and bone \u2013 harnessing an ultrasonically activated stream","volume":"17","author":"Birkin","year":"2015","journal-title":"Phys Chem Chem Phys"},{"key":"10.1016\/j.jhin.2020.09.021_bib40","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1177\/0022034515589284","article-title":"Removal of dental biofilms with an ultrasonically activated water stream","volume":"94","author":"Howlin","year":"2015","journal-title":"J\u00a0Dental Res"},{"key":"10.1016\/j.jhin.2020.09.021_bib41","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/2051-672X\/4\/3\/034009","article-title":"Bubbles vs biofilms: a novel method for the removal of marine biofilms attached on antifouling coatings using an ultrasonically activated water stream","volume":"4","author":"Salta","year":"2016","journal-title":"Surface Topogr Metrol Prop"},{"key":"10.1016\/j.jhin.2020.09.021_bib42","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/2051-672X\/4\/3\/034003","article-title":"A\u00a0comparison of ultrasonically activated water stream and ultrasonic bath immersion cleaning of railhead leaf-film contaminant","volume":"4","author":"Goodes","year":"2016","journal-title":"Surface Topogr Metrol Prop"},{"key":"10.1016\/j.jhin.2020.09.021_bib43","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1121\/1.5020786","article-title":"Acoustic radiation force on a parametrically distorted bubble","volume":"143","author":"Maksimov","year":"2018","journal-title":"J\u00a0Acoust Soc Amer"},{"key":"10.1016\/j.jhin.2020.09.021_bib44","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.idh.2017.08.004","article-title":"Evaluation of stainless steel surgical instruments subjected to multiple use\/processing","volume":"23","author":"Costa","year":"2018","journal-title":"Infect Dis Health"},{"key":"10.1016\/j.jhin.2020.09.021_bib45","doi-asserted-by":"crossref","first-page":"4982","DOI":"10.1039\/c3cp55088e","article-title":"An electrochemical and high-speed imaging study of micropore decontamination by acoustic bubble entrapment","volume":"16","author":"Offin","year":"2014","journal-title":"Phys Chem Chem Phys"},{"issue":"5","key":"10.1016\/j.jhin.2020.09.021_bib46","doi-asserted-by":"crossref","DOI":"10.1080\/00202967.2020.1805221","article-title":"Industrial lubricant removal using an ultrasonically activated water stream, with potential application for coronavirus decontamination and infection prevention for SARS-CoV-2","volume":"98","author":"Malakoutikhah","year":"2020","journal-title":"Trans Inst Metal Finish"},{"key":"10.1016\/j.jhin.2020.09.021_bib47","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.jhin.2012.08.008","article-title":"Current limitations about the cleaning of luminal endoscopes","volume":"83","author":"Herv\u00e9","year":"2013","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib48","first-page":"971","article-title":"A\u00a0simple method for blocking the deep cervical nerve plexus using an ultrasound-guided technique","volume":"39","author":"Saranteas","year":"2011","journal-title":"Anaesth Intens Care"},{"key":"10.1016\/j.jhin.2020.09.021_bib49","doi-asserted-by":"crossref","first-page":"2619","DOI":"10.1099\/vir.0.82228-0","article-title":"Amyloid-specific fluorophores for the rapid, sensitive in situ detection of prion contamination on surgical instruments","volume":"88","author":"Lipscomb","year":"2007","journal-title":"J\u00a0Gen Virol"},{"key":"10.1016\/j.jhin.2020.09.021_bib50","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.mimet.2009.01.017","article-title":"A\u00a0rapid dual staining procedure for the quantitative discrimination of prion amyloid from tissues reveals how interactions between amyloid and lipids in tissue homogenates may hinder the detection of prions","volume":"77","author":"Herv\u00e9","year":"2009","journal-title":"J\u00a0Microbiol Methods"},{"key":"10.1016\/j.jhin.2020.09.021_bib51","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.jhin.2005.07.008","article-title":"Rapid method for the sensitive detection of protein contamination on surgical instruments","volume":"62","author":"Lipscomb","year":"2006","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2020.09.021_bib52","doi-asserted-by":"crossref","first-page":"105","DOI":"10.2166\/wst.2003.0293","article-title":"Rapid detection of biofilms and adherent pathogens using scanning confocal laser microscopy and episcopic differential interference contrast microscopy","volume":"47","author":"Keevil","year":"2003","journal-title":"Water Sci Technol"},{"key":"10.1016\/j.jhin.2020.09.021_bib53","doi-asserted-by":"crossref","DOI":"10.1121\/2.0001260","article-title":"Analogies in contextualizing human response to airborne ultrasound and fish response to acoustic noise and deterrents","volume":"37","author":"Leighton","year":"2019","journal-title":"Proc Meet Acoust"},{"key":"10.1016\/j.jhin.2020.09.021_bib54","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jviromet.2009.10.010","article-title":"In\u00a0vitro infectivity assay for prion titration for application to the evaluation of the prion removal capacity of biological products manufacturing processes","volume":"164","author":"You","year":"2010","journal-title":"J\u00a0Virol Methods"},{"key":"10.1016\/j.jhin.2020.09.021_bib55","doi-asserted-by":"crossref","first-page":"11","DOI":"10.3310\/hta24110","article-title":"Interventions to reduce the risk of surgically transmitted Creutzfeldt\u2013Jakob disease: a cost-effective modelling review","volume":"24","author":"Stevenson","year":"2020","journal-title":"Health Technol Assess"}],"container-title":["Journal of Hospital Infection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670120304369?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670120304369?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T04:16:21Z","timestamp":1759292181000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0195670120304369"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12]]},"references-count":55,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["S0195670120304369"],"URL":"https:\/\/doi.org\/10.1016\/j.jhin.2020.09.021","relation":{},"ISSN":["0195-6701"],"issn-type":[{"value":"0195-6701","type":"print"}],"subject":[],"published":{"date-parts":[[2020,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A cold water, ultrasonically activated stream efficiently removes proteins and prion-associated amyloid from surgical stainless steel","name":"articletitle","label":"Article Title"},{"value":"Journal of Hospital Infection","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhin.2020.09.021","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}