{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T06:10:29Z","timestamp":1781071829883,"version":"3.54.1"},"reference-count":20,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T00:00:00Z","timestamp":1635724800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T00:00:00Z","timestamp":1635724800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100012317","name":"UCLH Biomedical Research Centre","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100012317","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journalofhospitalinfection.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hospital Infection"],"published-print":{"date-parts":[[2021,11]]},"DOI":"10.1016\/j.jhin.2021.08.016","type":"journal-article","created":{"date-parts":[[2021,8,21]],"date-time":"2021-08-21T10:27:37Z","timestamp":1629541657000},"page":"103-110","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"special_numbering":"C","title":["Thermal disinfection at suboptimal temperature of Pseudomonas aeruginosa biofilm on copper pipe and shower hose materials"],"prefix":"10.1016","volume":"117","author":[{"given":"S.","family":"Yui","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Karia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Ali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Muzslay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhin.2021.08.016_bib1","series-title":"Pseudomonas aeruginosa bacteraemia: annual data","year":"2019"},{"key":"10.1016\/j.jhin.2021.08.016_bib2","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.jhin.2016.11.014","article-title":"Long-term mortality following Pseudomonas aeruginosa bloodstream infection","volume":"95","author":"McCarthy","year":"2017","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2021.08.016_bib3","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jhin.2007.06.019","article-title":"Contribution of tap water to patient colonisation with Pseudomonas aeruginosa in a medical intensive care unit","volume":"67","author":"Rogues","year":"2007","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2021.08.016_bib4","doi-asserted-by":"crossref","first-page":"937","DOI":"10.1002\/mbo3.391","article-title":"Pseudomonas aeruginosa in premise plumbing of large buildings","volume":"5","author":"B\u00e9dard","year":"2016","journal-title":"Microbiol Open"},{"key":"10.1016\/j.jhin.2021.08.016_bib5","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1016\/j.watres.2017.12.027","article-title":"Biofilms in shower hoses","volume":"131","author":"Proctor","year":"2018","journal-title":"Water Res"},{"key":"10.1016\/j.jhin.2021.08.016_bib6","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.jhin.2013.10.003","article-title":"Investigation of healthcare-acquired infections associated with Pseudomonas aeruginosa biofilms in taps in neonatal units in Northern Ireland","volume":"86","author":"Walker","year":"2014","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2021.08.016_bib7","series-title":"Health Technical Memorandum (HTM) 04-01: Part B","year":"2016"},{"key":"10.1016\/j.jhin.2021.08.016_bib8","series-title":"Boil water. Technical Brief","year":"2015"},{"key":"10.1016\/j.jhin.2021.08.016_bib9","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.jhin.2010.09.012","article-title":"Effectiveness of different methods to control legionella in the water supply: ten-year experience in an Italian university hospital","volume":"77","author":"Marchesi","year":"2011","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2021.08.016_bib10","series-title":"ISO\/IEC 17025:2017: general requirements for the competence of testing and calibration laboratories","year":"2017"},{"key":"10.1016\/j.jhin.2021.08.016_bib11","series-title":"Technical Bulletin \u2013 guidance on water matrices definitions for sampling and testing to ISO\/IEC 17025","year":"2019"},{"key":"10.1016\/j.jhin.2021.08.016_bib12","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1016\/j.watres.2006.01.032","article-title":"Thermal inactivation of water-borne pathogenic and indicator bacteria at sub-boiling temperatures","volume":"40","author":"Spinks","year":"2006","journal-title":"Water Res"},{"key":"10.1016\/j.jhin.2021.08.016_bib13","doi-asserted-by":"crossref","first-page":"282","DOI":"10.5301\/ijao.5000590","article-title":"Stopping conventional showering decreases pseudomonas infections in left ventricular assist device patients","volume":"40","author":"Aburjania","year":"2017","journal-title":"Int J Artif Organs"},{"key":"10.1016\/j.jhin.2021.08.016_bib14","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.ijheh.2010.05.003","article-title":"Integration of Pseudomonas aeruginosa and Legionella pneumophila in drinking water biofilms grown on domestic plumbing materials","volume":"213","author":"Moritz","year":"2010","journal-title":"Int J Hyg Environ Health"},{"key":"10.1016\/j.jhin.2021.08.016_bib15","series-title":"Thermal conductivity of selected materials and gases","year":"2003"},{"key":"10.1016\/j.jhin.2021.08.016_bib16","series-title":"Thermal conductivity of metals, metallic elements and alloys","year":"2005"},{"key":"10.1016\/j.jhin.2021.08.016_bib17","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1016\/j.jhin.2011.03.019","article-title":"Disinfection of meticillin-resistant Staphylococcus aureus and Staphylococcus epidermidis biofilms using a remote non-thermal gas plasma","volume":"78","author":"Cotter","year":"2011","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2021.08.016_bib18","doi-asserted-by":"crossref","first-page":"2959","DOI":"10.1128\/AEM.03873-15","article-title":"Control of legionella contamination and risk of\u00a0corrosion in hospital water networks following various disinfection procedures","volume":"82","author":"Marchesi","year":"2016","journal-title":"Appl Environ Microbiol"},{"key":"10.1016\/j.jhin.2021.08.016_bib19","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1016\/j.watres.2017.12.027","article-title":"Biofilms in shower hoses","volume":"131","author":"Proctor","year":"2017","journal-title":"Water Res"},{"key":"10.1016\/j.jhin.2021.08.016_bib20","doi-asserted-by":"crossref","first-page":"2872","DOI":"10.1128\/AEM.03529-15","article-title":"Biofilms on hospital shower hoses: characterization and implications for nosocomial infections","volume":"82","author":"Soto-Giron","year":"2016","journal-title":"Appl Environ Microbiol"}],"container-title":["Journal of Hospital Infection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670121003017?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670121003017?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T04:19:56Z","timestamp":1759292396000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0195670121003017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11]]},"references-count":20,"alternative-id":["S0195670121003017"],"URL":"https:\/\/doi.org\/10.1016\/j.jhin.2021.08.016","relation":{},"ISSN":["0195-6701"],"issn-type":[{"value":"0195-6701","type":"print"}],"subject":[],"published":{"date-parts":[[2021,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Thermal disinfection at suboptimal temperature of Pseudomonas aeruginosa biofilm on copper pipe and shower hose materials","name":"articletitle","label":"Article Title"},{"value":"Journal of Hospital Infection","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhin.2021.08.016","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}