{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T07:51:53Z","timestamp":1782460313333,"version":"3.54.5"},"reference-count":22,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,3,1]],"date-time":"2023-03-01T00:00:00Z","timestamp":1677628800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,3,1]],"date-time":"2023-03-01T00:00:00Z","timestamp":1677628800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journalofhospitalinfection.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hospital Infection"],"published-print":{"date-parts":[[2023,3]]},"DOI":"10.1016\/j.jhin.2022.12.015","type":"journal-article","created":{"date-parts":[[2023,1,11]],"date-time":"2023-01-11T11:11:51Z","timestamp":1673435511000},"page":"49-54","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"special_numbering":"C","title":["Improving parametric load release for steam sterilization"],"prefix":"10.1016","volume":"133","member":"78","reference":[{"key":"10.1016\/j.jhin.2022.12.015_bib1","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1016\/S0140-6736(59)92258-5","article-title":"Sterilisation by steam under increased pressure","volume":"273","author":"Working party on Pressure Steam Sterilizers of the Medical Research","year":"1959","journal-title":"The Lancet"},{"key":"10.1016\/j.jhin.2022.12.015_bib2","series-title":"International Organisation for Standardisation: sterilization of health care products - moist heat \u2013 requirements for the development, validation and routine control of a sterilization process for medical devices","year":"2006"},{"key":"10.1016\/j.jhin.2022.12.015_bib3","series-title":"Association for the Advancement of Medical Instrumentation\/American National Standards Institute: comprehensive guide to steam sterilizations and sterility assurance in health care facilities","year":"2017"},{"key":"10.1016\/j.jhin.2022.12.015_bib4","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1016\/S0140-6736(63)92519-4","article-title":"The Bowie and Dick autoclave tape test","volume":"281","author":"Bowie","year":"1963","journal-title":"The Lancet"},{"key":"10.1016\/j.jhin.2022.12.015_bib5","series-title":"EN285:2015+A1:2021 Large sterilizers","year":"2021"},{"key":"10.1016\/j.jhin.2022.12.015_bib6","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1016\/0017-9310(79)90058-9","article-title":"A\u00a0general correlation for heat transfer during film condensation inside pipes","volume":"22","author":"Shah","year":"1979","journal-title":"Int J Heat Mass Transfer"},{"key":"10.1016\/j.jhin.2022.12.015_bib7","doi-asserted-by":"crossref","DOI":"10.1063\/1.4829636","article-title":"Measuring non-condensable gases in steam","volume":"84","author":"van Doornmalen","year":"2013","journal-title":"Rev Sci Instrum"},{"key":"10.1016\/j.jhin.2022.12.015_bib8","article-title":"Penetration of water vapour into narrow channels during steam sterilization processes","volume":"46","author":"Doornmalen van","year":"2013","journal-title":"J\u00a0Physics D: Appl Phys"},{"key":"10.1016\/j.jhin.2022.12.015_bib9","series-title":"International Organization for Standardization Sterilization of health care products \u2013 chemical indicators \u2013 Part 3: class 2 indicator systems for use in the Bowie and Dick-type steam penetration test","year":"2007"},{"key":"10.1016\/j.jhin.2022.12.015_bib10","series-title":"International Organization for Standardization, Sterilization of health care products \u2013 chemical indicators \u2013 Part 4: class 2 indicators as an alternative to the Bowie and Dick-type test for detection of steam penetration","year":"2007"},{"key":"10.1016\/j.jhin.2022.12.015_bib11","series-title":"International Organization for Standardization, Sterilization of health care products \u2013 chemical indicators \u2013 Part 5: class 2 indicators for Bowie and Dick-type air removal tests","year":"2007"},{"key":"10.1016\/j.jhin.2022.12.015_bib12","unstructured":"Standard ISO\/DIS 11140-6. International Organization for Standardization, Sterilization of health care products \u2014 chemical indicators \u2014 Part 6: type 2 indicators and process challenge devices for use in performance testing of small steam sterilizers, Under Development."},{"key":"10.1016\/j.jhin.2022.12.015_bib13","doi-asserted-by":"crossref","DOI":"10.3389\/fmedt.2020.566143","article-title":"Monitoring steam penetration in channelled instruments: an evidence-based worst-case for practical situations","volume":"2","author":"Tessarolo","year":"2020","journal-title":"Front Med Technol"},{"key":"10.1016\/j.jhin.2022.12.015_bib14","series-title":"An evaluation of nine bowie and dick test products available in the United Kingdom","author":"Kirk","year":"2012"},{"key":"10.1016\/j.jhin.2022.12.015_bib15","series-title":"Steam and gas tables with computer equations","author":"Irvine","year":"1984"},{"key":"10.1016\/j.jhin.2022.12.015_bib16","unstructured":"International Association for the Properties of Water and Steam. Available at: https:\/\/www.iapws.org\/ [last accessed June-2022]."},{"key":"10.1016\/j.jhin.2022.12.015_bib18","doi-asserted-by":"crossref","first-page":"276","DOI":"10.5731\/pdajpst.2017.008490","article-title":"The relation between the load, duration and steam penetration capacity of a surface steam sterilization process; a case study","volume":"73","author":"van Doornmalen","year":"2019","journal-title":"PDA J Pharm Sci Technol"},{"key":"10.1016\/j.jhin.2022.12.015_bib19","unstructured":"3M\u2122 Electronic Test System 4308. Available at: https:\/\/www.3m.co.uk\/3M\/en_GB\/p\/d\/v101230002\/ [last accessed June 2022]."},{"key":"10.1016\/j.jhin.2022.12.015_bib20","unstructured":"NCG Sensor system. Available at: https:\/\/www.solidtoo.com\/en\/ncg-sensor-system\/ [last accessed June 2022]."},{"key":"10.1016\/j.jhin.2022.12.015_bib21","series-title":"Transport phenomena","author":"Bird","year":"2007"},{"key":"10.1016\/j.jhin.2022.12.015_bib22","first-page":"320","article-title":"A\u00a0case study of steam penetration monitoring indicates the necessity of Every Load Monitoring of steam sterilization processes","volume":"5","author":"van Doornmalen","year":"2016","journal-title":"Central Service"},{"key":"10.1016\/j.jhin.2022.12.015_bib23","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1016\/j.applthermaleng.2018.10.135","article-title":"CFD investigations of steam penetration, air-removal and condensation inside hollow loads and cavities","volume":"147","author":"Feurhuber","year":"2019","journal-title":"Appl Thermal Eng"}],"container-title":["Journal of Hospital Infection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S019567012300004X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S019567012300004X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T04:21:57Z","timestamp":1759292517000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S019567012300004X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3]]},"references-count":22,"alternative-id":["S019567012300004X"],"URL":"https:\/\/doi.org\/10.1016\/j.jhin.2022.12.015","relation":{},"ISSN":["0195-6701"],"issn-type":[{"value":"0195-6701","type":"print"}],"subject":[],"published":{"date-parts":[[2023,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Improving parametric load release for steam sterilization","name":"articletitle","label":"Article Title"},{"value":"Journal of Hospital Infection","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhin.2022.12.015","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}