{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T05:27:58Z","timestamp":1790141278965,"version":"4.0.1"},"reference-count":37,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,6,1]],"date-time":"2023-06-01T00:00:00Z","timestamp":1685577600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,6,1]],"date-time":"2023-06-01T00:00:00Z","timestamp":1685577600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,3,21]],"date-time":"2023-03-21T00:00:00Z","timestamp":1679356800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journalofhospitalinfection.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hospital Infection"],"published-print":{"date-parts":[[2023,6]]},"DOI":"10.1016\/j.jhin.2023.03.013","type":"journal-article","created":{"date-parts":[[2023,3,23]],"date-time":"2023-03-23T18:13:18Z","timestamp":1679595198000},"page":"100-109","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"special_numbering":"C","title":["Evaluation of cold atmospheric plasma for the decontamination of flexible endoscopes"],"prefix":"10.1016","volume":"136","author":[{"given":"R.C.","family":"Herv\u00e9","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.G.","family":"Kong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Bhatt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H-L.","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.E.","family":"Comoy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J-P.","family":"Deslys","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.J.","family":"Secker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.W.","family":"Keevil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhin.2023.03.013_bib1","series-title":"Disinfection, sterilization, and preservation","first-page":"517","article-title":"Chemical disinfection of medical and surgical materials","author":"Spaulding","year":"1968"},{"key":"10.1016\/j.jhin.2023.03.013_bib2","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.jhin.2012.08.008","article-title":"Current limitations about the cleaning of luminal endoscopes","volume":"83","author":"Herv\u00e9","year":"2013","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2023.03.013_bib3","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1016\/j.gie.2010.09.028","article-title":"Delayed reprocessing of endoscopes","volume":"73","author":"Agrawal","year":"2011","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.jhin.2023.03.013_bib4","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.ajic.2012.02.030","article-title":"Comparison of adenosine triphosphate, microbiological load, and residual protein as indicators for assessing the cleanliness of flexible gastrointestinal endoscopes","volume":"41","author":"Fushimi","year":"2013","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2023.03.013_bib5","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1016\/j.ajic.2015.03.003","article-title":"Persistent contamination on colonoscopes and gastroscopes detected by biologic cultures and rapid indicators despite reprocessing performed in accordance with guidelines","volume":"43","author":"Ofstead","year":"2015","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2023.03.013_bib6","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1055\/s-0042-105744","article-title":"Persistent residual contamination in endoscope channels; a fluorescence epimicroscopy study","volume":"48","author":"Herv\u00e9","year":"2016","journal-title":"Endoscopy"},{"key":"10.1016\/j.jhin.2023.03.013_bib7","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/j.jhin.2017.07.012","article-title":"Endoscope drying and its pitfalls","volume":"97","author":"Kovaleva","year":"2017","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2023.03.013_bib8","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1111\/jam.12837","article-title":"Improved recovery of Listeria monocytogenes from stainless steel and polytetrafluoroethylene surfaces using air\/water ablation","volume":"119","author":"Gi\u00e3o","year":"2015","journal-title":"J\u00a0Appl Microbiol"},{"key":"10.1016\/j.jhin.2023.03.013_bib9","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1016\/j.ajic.2012.07.008","article-title":"Early identification and control of carbapenemase-producing Klebsiella pneumoniae, originating from contaminated endoscopic equipment","volume":"41","author":"Alrabaa","year":"2013","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2023.03.013_bib10","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1055\/s-0030-1255647","article-title":"Multidrug-resistant Klebsiella pneumoniae outbreak after endoscopic retrograde cholangiopancreatography","volume":"42","author":"Aumeran","year":"2010","journal-title":"Endoscopy"},{"key":"10.1016\/j.jhin.2023.03.013_bib11","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.jhin.2012.10.016","article-title":"Gastroscopy-associated transmission of extended-spectrum beta-lactamase-producing Pseudomonas aeruginosa","volume":"83","author":"Bajolet","year":"2013","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2023.03.013_bib12","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.jhin.2013.06.010","article-title":"Outbreak of ertapenem-resistant Enterobacter cloacae urinary tract infections due to a contaminated ureteroscope","volume":"85","author":"Chang","year":"2013","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2023.03.013_bib13","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.1001\/jama.2014.12720","article-title":"New Delhi metallo-beta-lactamase-producing carbapenem-resistant Escherichia coli associated with exposure to duodenoscopes","volume":"312","author":"Epstein","year":"2014","journal-title":"JAMA"},{"key":"10.1016\/j.jhin.2023.03.013_bib14","first-page":"588","article-title":"Outbreak of cystoscopy related infections with Pseudomonas aeruginosa: New Mexico, 2007","volume":"180","author":"Wendelboe","year":"2008","journal-title":"J\u00a0Urol"},{"key":"10.1016\/j.jhin.2023.03.013_bib15","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1017\/ice.2015.66","article-title":"Endoscopic retrograde cholangiopancreatography-associated AmpC outbreak","volume":"36","author":"Wendorf","year":"2015","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jhin.2023.03.013_bib16","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/j.jhin.2017.07.030","article-title":"Endoscopy in the twenty-first century: minimally invasive state-of-the-art medical technology or a future main vector of hospital-acquired infections?","volume":"97","author":"Herv\u00e9","year":"2017","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2023.03.013_bib17","doi-asserted-by":"crossref","DOI":"10.1136\/bmjgast-2019-000282","article-title":"Use of ethylene-oxide gas sterilisation to terminate multidrug-resistant bacterial outbreaks linked to duodenoscopes","volume":"6","author":"Muscarella","year":"2019","journal-title":"BMJ Open Gastroenterol"},{"key":"10.1016\/j.jhin.2023.03.013_bib18","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/j.gie.2016.01.055","article-title":"Impact of ethylene oxide gas sterilization of duodenoscopes after a carbapenem-resistant Enterobacteriaceae outbreak","volume":"84","author":"Naryzhny","year":"2016","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.jhin.2023.03.013_bib19","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1126\/science.6801762","article-title":"Novel proteinaceous infectious particles cause scrapie","volume":"216","author":"Prusiner","year":"1982","journal-title":"Science"},{"key":"10.1016\/j.jhin.2023.03.013_bib20","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1055\/s-2001-18937","article-title":"Variant Creutzfeldt\u2013Jakob disease (vCJD) and gastrointestinal endoscopy","volume":"33","author":"Axon","year":"2001","journal-title":"Endoscopy"},{"key":"10.1016\/j.jhin.2023.03.013_bib21","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.jhin.2010.01.024","article-title":"Current risk of iatrogenic Creutzfeld\u2013Jakob disease in the UK: efficacy of available cleaning chemistries and reusability of neurosurgical instruments","volume":"75","author":"Herv\u00e9","year":"2010","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2023.03.013_bib22","series-title":"Health Technical Memorandum (HTM) 01-06. Management and decontamination of flexible endoscopes","year":"2016"},{"key":"10.1016\/j.jhin.2023.03.013_bib23","series-title":"Transmissible spongiform encephalopathy agents: safe working and the prevention of infection: Annex F. London","year":"2015"},{"key":"10.1016\/j.jhin.2023.03.013_bib24","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.jhin.2019.08.005","article-title":"Prion disease and recommended procedures for flexible endoscope reprocessing \u2013 a review of policies worldwide and proposal for a simplified approach","volume":"104","author":"Kampf","year":"2020","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2023.03.013_bib25","doi-asserted-by":"crossref","first-page":"24","DOI":"10.3390\/pathogens10010024","article-title":"Inactivation of prions by low-temperature sterilization technology using vaporized gas derived from a hydrogen peroxide-peracetic acid mixture","volume":"10","author":"Sakudo","year":"2020","journal-title":"Pathogens"},{"key":"10.1016\/j.jhin.2023.03.013_bib26","doi-asserted-by":"crossref","DOI":"10.3390\/ijms231810241","article-title":"Recent advances in prion inactivation by plasma sterilizer","volume":"23","author":"Sakudo","year":"2022","journal-title":"Int J Mol Sci"},{"key":"10.1016\/j.jhin.2023.03.013_bib27","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.jhin.2014.06.015","article-title":"Cold atmospheric pressure plasma and decontamination. Can it contribute to preventing hospital-acquired infections?","volume":"88","author":"O'Connor","year":"2014","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2023.03.013_bib28","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.gie.2018.08.009","article-title":"Efficacy of low-temperature plasma-activated gas disinfection against biofilm on contaminated GI endoscope channels","volume":"89","author":"Bhatt","year":"2019","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.jhin.2023.03.013_bib29","doi-asserted-by":"crossref","DOI":"10.1063\/1.2817965","article-title":"Room-temperature atmospheric argon plasma jet sustained with submicrosecond high-voltage pulses","volume":"91","author":"Walsh","year":"2007","journal-title":"Appl Phys Lett"},{"key":"10.1016\/j.jhin.2023.03.013_bib30","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.mimet.2009.01.017","article-title":"A\u00a0rapid dual staining procedure for the quantitative discrimination of prion amyloid from tissues reveals how interactions between amyloid and lipids in tissue homogenates may hinder the detection of prions","volume":"77","author":"Herv\u00e9","year":"2009","journal-title":"J\u00a0Microbiol Methods"},{"key":"10.1016\/j.jhin.2023.03.013_bib31","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.mimet.2007.06.005","article-title":"Investigations of a prion infectivity assay to evaluate methods of decontamination","volume":"70","author":"Fichet","year":"2007","journal-title":"J\u00a0Microbiol Methods"},{"key":"10.1016\/j.jhin.2023.03.013_bib32","first-page":"493","article-title":"A\u00a0simple method of estimating fifty per cent endpoints","volume":"27","author":"Reed","year":"1938","journal-title":"Am J Hyg"},{"key":"10.1016\/j.jhin.2023.03.013_bib33","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/S0014-5793(02)02338-4","article-title":"PrP-dependent cell adhesion in N2a neuroblastoma cells","volume":"514","author":"Mang\u00e9","year":"2002","journal-title":"FEBS Lett"},{"key":"10.1016\/j.jhin.2023.03.013_bib34","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.jhin.2022.09.020","article-title":"Sensitive microscopic quantification of surface bound prion infectivity for the assessment of surgical instrument decontamination procedures","volume":"132","author":"Secker","year":"2023","journal-title":"J\u00a0Hosp Infect"},{"key":"10.1016\/j.jhin.2023.03.013_bib35","doi-asserted-by":"crossref","first-page":"3479","DOI":"10.1073\/pnas.0813342106","article-title":"Highly sensitive, quantitative cell-based assay for prions adsorbed to solid surfaces","volume":"106","author":"Edgeworth","year":"2009","journal-title":"Proc Natl Acad Sci USA"},{"key":"10.1016\/j.jhin.2023.03.013_bib36","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1002\/ppap.200900121","article-title":"Inactivation of bacteria and biomolecules by low-pressure plasma discharges","volume":"7","author":"von Keudell","year":"2010","journal-title":"Plasma Process Polym"},{"key":"10.1016\/j.jhin.2023.03.013_bib37","doi-asserted-by":"crossref","first-page":"646","DOI":"10.2307\/30141493","article-title":"An evaluation of the AbTox Plazlyte Sterilization System","volume":"18","author":"Bryce","year":"1997","journal-title":"Infect Control Hosp Epidemiol"}],"container-title":["Journal of Hospital Infection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670123000993?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670123000993?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T04:22:36Z","timestamp":1759292556000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0195670123000993"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6]]},"references-count":37,"alternative-id":["S0195670123000993"],"URL":"https:\/\/doi.org\/10.1016\/j.jhin.2023.03.013","relation":{},"ISSN":["0195-6701"],"issn-type":[{"value":"0195-6701","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of cold atmospheric plasma for the decontamination of flexible endoscopes","name":"articletitle","label":"Article Title"},{"value":"Journal of Hospital Infection","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhin.2023.03.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Author(s). Published by Elsevier Ltd on behalf of The Healthcare Infection Society.","name":"copyright","label":"Copyright"}]}}