{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T22:41:13Z","timestamp":1760654473199,"version":"build-2065373602"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journalofhospitalinfection.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hospital Infection"],"published-print":{"date-parts":[[2025,7]]},"DOI":"10.1016\/j.jhin.2025.04.012","type":"journal-article","created":{"date-parts":[[2025,4,25]],"date-time":"2025-04-25T19:01:56Z","timestamp":1745607716000},"page":"114-118","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Comparative in-vitro antimicrobial activity of silver- and minocycline\u2013rifampin\u2013chlorhexidine-coated needle-free connectors"],"prefix":"10.1016","volume":"161","author":[{"given":"Y.","family":"Truong","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Rosenblatt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Gerges","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I.","family":"Raad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhin.2025.04.012_bib1","article-title":"Disinfection of needleless connector hubs: clinical evidence systematic review","volume":"2015","author":"Moureau","year":"2015","journal-title":"Nurs Res Pract"},{"key":"10.1016\/j.jhin.2025.04.012_bib2","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1177\/0885066618795126","article-title":"Anatomic site-specific complication rates for central venous catheter insertions","volume":"35","author":"Bell","year":"2020","journal-title":"J Intensive Care Med"},{"key":"10.1016\/j.jhin.2025.04.012_bib3","article-title":"Prevalence of central line-associated bloodstream infections (CLABSI) in intensive care and medical-surgical units","volume":"14","author":"Toor","year":"2022","journal-title":"Cureus"},{"key":"10.1016\/j.jhin.2025.04.012_bib4","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.jhin.2021.03.005","article-title":"Challenges in reducing the risk of infection when accessing vascular catheters","volume":"113","author":"Greene","year":"2021","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.04.012_bib5","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1128\/JCM.02220-13","article-title":"Microbial biofilms on needleless connectors for central venous catheters: comparison of standard and silver-coated devices collected from patients in an acute care hospital","volume":"52","author":"Perez","year":"2014","journal-title":"J Clin Microbiol"},{"key":"10.1016\/j.jhin.2025.04.012_bib6","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.ajic.2012.03.020","article-title":"In vitro study assessing the antibacterial activity of three silver-impregnated\/coated mechanical valve needleless connectors after blood exposure","volume":"41","author":"Chernecky","year":"2013","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2025.04.012_bib7","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1016\/j.ajic.2019.01.002","article-title":"Methods for microbial needleless connector decontamination: a systematic review and meta-analysis","volume":"47","author":"Flynn","year":"2019","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2025.04.012_bib8","doi-asserted-by":"crossref","first-page":"1179","DOI":"10.1128\/AAC.01959-13","article-title":"Prevention of biofilm colonization by Gram-negative bacteria on minocycline\u2013rifampin-impregnated catheters sequentially coated with chlorhexidine","volume":"58","author":"Jamal","year":"2014","journal-title":"Antimicrob Agents Chemother"},{"key":"10.1016\/j.jhin.2025.04.012_bib9","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1017\/ice.2021.150","article-title":"Review of allergic reactions from use of chlorhexidine on medical products in clinical settings over 40 years: risks and mitigations","volume":"43","author":"Gerges","year":"2022","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jhin.2025.04.012_bib10","doi-asserted-by":"crossref","DOI":"10.1093\/jacamr\/dlaa002","article-title":"The potential for developing new antimicrobial resistance from the use of medical devices containing chlorhexidine, minocycline, rifampicin and their combinations: a systematic review","volume":"2","author":"Reitzel","year":"2020","journal-title":"JAC Antimicrob Resist"},{"key":"10.1016\/j.jhin.2025.04.012_bib11","doi-asserted-by":"crossref","DOI":"10.1128\/AAC.00040-19","article-title":"Assessment of the potential for inducing resistance in multidrug-resistant organisms from exposure to minocycline, rifampin, and chlorhexidine used to treat intravascular devices","volume":"63","author":"Rosenblatt","year":"2019","journal-title":"Antimicrob Agents Chemother"},{"year":"2024","series-title":"K241115 SV spectrum MRC central venous catheter; SV spectrum MR central venous catheter; SV central venous catheter","author":"Wolloscheck","key":"10.1016\/j.jhin.2025.04.012_bib12"},{"issue":"Suppl. 1","key":"10.1016\/j.jhin.2025.04.012_bib13","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/NAN.0000000000000396","article-title":"Infusion therapy standards of practice, 8th edition","volume":"44","author":"Gorski","year":"2021","journal-title":"J Infus Nurs"},{"key":"10.1016\/j.jhin.2025.04.012_bib14","doi-asserted-by":"crossref","DOI":"10.1016\/j.iccn.2023.103414","article-title":"Determination of microbial contamination on the outer surface of needleless connectors before and after disinfection","volume":"77","author":"Akb\u0131y\u0131k","year":"2023","journal-title":"Intensive Crit Care Nurs"},{"key":"10.1016\/j.jhin.2025.04.012_bib15","article-title":"A protocol to set up needle-free connector with positive displacement on central venous catheter in intensive care unit","volume":"149","author":"Clavier","year":"2019","journal-title":"J Visual Exp"},{"key":"10.1016\/j.jhin.2025.04.012_bib16","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.addr.2016.07.011","article-title":"Drug eluting antimicrobial vascular catheters: progress and promise","volume":"112","author":"Viola","year":"2017","journal-title":"Adv Drug Deliv Rev"},{"key":"10.1016\/j.jhin.2025.04.012_bib17","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.ijid.2014.09.018","article-title":"Effectiveness of silver-impregnated central venous catheters for preventing catheter-related blood stream infections: a meta-analysis","volume":"29","author":"Chen","year":"2014","journal-title":"Int J Infect Dis"},{"key":"10.1016\/j.jhin.2025.04.012_bib18","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/0040-6031(83)80324-4","article-title":"Thermodynamic properties of the silver ion in alcohol + water solvent mixtures from electromotive force measurements and thermodynamic solubility product constants of AgX (X = Cl, Br, I or CNS) at different temperatures","volume":"63","author":"Dash","year":"1983","journal-title":"Thermochim Acta"},{"key":"10.1016\/j.jhin.2025.04.012_bib19","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/S0099-5428(08)60328-7","volume":"5","author":"Gallo","year":"1976","journal-title":"Rifampin. Anal Profiles Drug Subst"},{"key":"10.1016\/j.jhin.2025.04.012_bib20","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1111\/j.1600-0765.1973.tb02158.x","article-title":"Chlorhexidine\u2013protein interactions","volume":"12","author":"Hjeljord","year":"1973","journal-title":"J Periodontal Res Suppl"},{"key":"10.1016\/j.jhin.2025.04.012_bib21","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/S0099-5428(08)60348-2","article-title":"Minocycline","volume":"6","author":"Zbinovsky","year":"1977","journal-title":"Anal Profiles Drug Subst"},{"key":"10.1016\/j.jhin.2025.04.012_bib22","doi-asserted-by":"crossref","first-page":"1611","DOI":"10.1097\/01.ju.0000118245.66976.e1","article-title":"Efficacy of antibiotic impregnation of inflatable penile prostheses in decreasing infection in original implants","volume":"171","author":"Carson","year":"2004","journal-title":"J Urol"},{"key":"10.1016\/j.jhin.2025.04.012_bib23","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1177\/1553350616656280","article-title":"Evaluation of the antimicrobial efficacy of a novel rifampin\/minocycline-coated, noncrosslinked porcine acellular dermal matrix compared with uncoated scaffolds for soft tissue repair","volume":"23","author":"Majumder","year":"2016","journal-title":"Surg Innov"},{"key":"10.1016\/j.jhin.2025.04.012_bib24","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1056\/NEJMoa1901111","article-title":"Antibacterial envelope to prevent cardiac implantable device infection","volume":"380","author":"Tarakji","year":"2019","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jhin.2025.04.012_bib25","doi-asserted-by":"crossref","first-page":"725","DOI":"10.3171\/jns.2003.98.4.0725","article-title":"Efficacy of antimicrobial-impregnated external ventricular drain catheters: a prospective, randomized, controlled trial","volume":"98","author":"Zabramski","year":"2003","journal-title":"J Neurosurg"},{"key":"10.1016\/j.jhin.2025.04.012_bib26","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1128\/AAC.05836-11","article-title":"Improved antibiotic-impregnated catheters with extended-spectrum activity against resistant bacteria and fungi","volume":"56","author":"Raad","year":"2012","journal-title":"Antimicrob Agents Chemother"}],"container-title":["Journal of Hospital Infection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670125001021?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670125001021?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T21:58:41Z","timestamp":1760651921000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0195670125001021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":26,"alternative-id":["S0195670125001021"],"URL":"https:\/\/doi.org\/10.1016\/j.jhin.2025.04.012","relation":{},"ISSN":["0195-6701"],"issn-type":[{"type":"print","value":"0195-6701"}],"subject":[],"published":{"date-parts":[[2025,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparative in-vitro antimicrobial activity of silver- and minocycline\u2013rifampin\u2013chlorhexidine-coated needle-free connectors","name":"articletitle","label":"Article Title"},{"value":"Journal of Hospital Infection","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhin.2025.04.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Healthcare Infection Society. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}