{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T18:50:00Z","timestamp":1786992600444,"version":"build-2736575974"},"reference-count":24,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,6,28]],"date-time":"2025-06-28T00:00:00Z","timestamp":1751068800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journalofhospitalinfection.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hospital Infection"],"published-print":{"date-parts":[[2025,9]]},"DOI":"10.1016\/j.jhin.2025.06.013","type":"journal-article","created":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T02:28:10Z","timestamp":1751423290000},"page":"98-104","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Comparison of cleaning effects of vacuum-assisted boiling washer-disinfectors on rigid endoscopic instruments: impact of cleaning cycle parameters"],"prefix":"10.1016","volume":"163","author":[{"given":"H.-H.","family":"Tong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.-J.","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Y.-Y.","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.-Q.","family":"Yin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Y.","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.-H.","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhin.2025.06.013_bib1","first-page":"950","article-title":"Current status of management of central sterile supply department of 2,271 hospitals in China","author":"Kang","year":"2024","journal-title":"Chin J Nosocomiol"},{"key":"10.1016\/j.jhin.2025.06.013_bib2","doi-asserted-by":"crossref","first-page":"e53","DOI":"10.1016\/j.jhin.2018.11.001","article-title":"Complex design of surgical instruments as barrier for cleaning effectiveness, favouring biofilm formation","volume":"103","author":"Lopes","year":"2019","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.06.013_bib3","article-title":"Factors associated with cleaning quality of reusable medical devices at a single center in China","volume":"10","author":"Huang","year":"2024","journal-title":"Heliyon"},{"key":"10.1016\/j.jhin.2025.06.013_bib4","series-title":"Executive brief: top 10 Patient safety concerns","year":"2024"},{"key":"10.1016\/j.jhin.2025.06.013_bib5","doi-asserted-by":"crossref","first-page":"A114","DOI":"10.1016\/j.ajic.2023.04.158","article-title":"Biofilms on medical instruments and surfaces: do they interfere with instrument reprocessing and surface disinfection","volume":"51","author":"Weber","year":"2023","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2025.06.013_bib6","first-page":"86","article-title":"Application of pulsating vacuum cleaner in reprocessing of endoscopic instruments","volume":"35","author":"Zhou","year":"2020","journal-title":"J Nur Sci"},{"key":"10.1016\/j.jhin.2025.06.013_bib7","series-title":"Comprehensive guide to steam sterilization and sterility assurance in health care facilities. Document AAMI ST79","year":"2013"},{"key":"10.1016\/j.jhin.2025.06.013_bib8","series-title":"Health Industrial Standard (WS310.3-2016) of the People\u2019s Republic of China \u2013 central sterile supply department (CSSD) \u2013 Part 3: surveillance standard for cleaning, disinfection and sterilization","year":"2016"},{"key":"10.1016\/j.jhin.2025.06.013_bib9","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.jhin.2023.12.005","article-title":"Smart-detection approach for protein residues to evaluate the cleaning efficacy of reusable medical devices","volume":"145","author":"Ouirungroj","year":"2024","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.06.013_bib10","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.idh.2016.11.003","article-title":"A suggested sampling algorithm for use with ATP testing in cleanliness measurement","volume":"21","author":"Whiteley","year":"2016","journal-title":"Infect Dis Health"},{"key":"10.1016\/j.jhin.2025.06.013_bib11","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1093\/bjs\/znab376","article-title":"Laparoscopic versus open resection of hepatocellular carcinoma in patients with cirrhosis: meta-analysis","volume":"109","author":"Kabir","year":"2021","journal-title":"Br J Surg"},{"key":"10.1016\/j.jhin.2025.06.013_bib12","doi-asserted-by":"crossref","DOI":"10.1016\/j.scitotenv.2023.165673","article-title":"Use of real-time immersive digital training and educational technologies to improve patient safety during the processing of reusable medical devices: quo vadis?","volume":"900","author":"Kremer","year":"2023","journal-title":"Sci Total Environ"},{"key":"10.1016\/j.jhin.2025.06.013_bib13","doi-asserted-by":"crossref","DOI":"10.1016\/j.scitotenv.2023.162976","article-title":"A review of Spaulding's classification system for effective cleaning, disinfection and sterilization of reusable medical devices: viewed through a modern-day lens that will inform and enable future sustainability","volume":"878","author":"Rowan","year":"2023","journal-title":"Sci Total Environ"},{"key":"10.1016\/j.jhin.2025.06.013_bib14","first-page":"3170","article-title":"Survey on the current status of centralized handling of hard endoscopes in 348 hospitals nationwide","volume":"33","author":"Wang","year":"2023","journal-title":"Chin J Nosocomiol"},{"key":"10.1016\/j.jhin.2025.06.013_bib15","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.ajic.2019.08.024","article-title":"Effectiveness of manual versus automated cleaning on Staphylococcus epidermidis biofilm removal from the surface of surgical instruments","volume":"48","author":"Evangelista","year":"2020","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2025.06.013_bib16","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.jhin.2022.03.011","article-title":"Hinged surgical instruments: efficacy of double manual cleaning versus automated cleaning on biofilm removal","volume":"124","author":"de Melo Costa","year":"2022","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.06.013_bib17","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1166\/jbt.2022.2979","article-title":"Application of pulsating vacuum cleaning technology to medical devices cleaning","volume":"12","author":"Yang","year":"2022","journal-title":"J Biomater Tiss Eng"},{"key":"10.1016\/j.jhin.2025.06.013_bib18","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.jhin.2025.01.005","article-title":"Impact of pretreatment strategies and cleaning methods on the cleaning efficacy of electrosurgical instruments: a multi-centre study","volume":"159","author":"Li","year":"2025","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.06.013_bib19","series-title":"Reprocessing of instruments to retain value","year":"2017"},{"key":"10.1016\/j.jhin.2025.06.013_bib20","first-page":"231","article-title":"Research progress on injury of surgical instruments and surface treatment","volume":"48","author":"Di","year":"2019","journal-title":"Surf Tech"},{"key":"10.1016\/j.jhin.2025.06.013_bib21","series-title":"Washer- disinfectors \u2013 Part 1: general requirements, terms and definitions and tests","year":"2024"},{"key":"10.1016\/j.jhin.2025.06.013_bib22","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/s13756-018-0308-2","article-title":"APSIC guidelines for disinfection and sterilization of instruments in health care facilities","volume":"7","author":"Ling","year":"2018","journal-title":"Antimicrob Resist Infect Control"},{"key":"10.1016\/j.jhin.2025.06.013_bib23","first-page":"37","article-title":"Rinsing methods of ophthalmic surgical instruments under the special condition of \"Health Express\"","volume":"21","author":"Ma","year":"2022","journal-title":"Chin J Infect Control"},{"key":"10.1016\/j.jhin.2025.06.013_bib24","first-page":"7","article-title":"Comparison of \u201cChemical Reaction Rate\u201d in Chinese and British Chemistry Textbooks","volume":"39","author":"Sun","year":"2018","journal-title":"Chin J Chem Educ"}],"container-title":["Journal of Hospital Infection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670125001975?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670125001975?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,4]],"date-time":"2025-11-04T13:27:12Z","timestamp":1762262832000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0195670125001975"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9]]},"references-count":24,"alternative-id":["S0195670125001975"],"URL":"https:\/\/doi.org\/10.1016\/j.jhin.2025.06.013","relation":{},"ISSN":["0195-6701"],"issn-type":[{"value":"0195-6701","type":"print"}],"subject":[],"published":{"date-parts":[[2025,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of cleaning effects of vacuum-assisted boiling washer-disinfectors on rigid endoscopic instruments: impact of cleaning cycle parameters","name":"articletitle","label":"Article Title"},{"value":"Journal of Hospital Infection","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhin.2025.06.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier Ltd on behalf of The Healthcare Infection Society.","name":"copyright","label":"Copyright"}]}}