{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T02:54:58Z","timestamp":1775098498299,"version":"3.50.1"},"reference-count":41,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100006229","name":"Oak Ridge Institute for Science and Education","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006229","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000038","name":"U.S. Food and Drug Administration","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journalofhospitalinfection.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hospital Infection"],"published-print":{"date-parts":[[2026,2]]},"DOI":"10.1016\/j.jhin.2025.10.034","type":"journal-article","created":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T13:50:10Z","timestamp":1763646610000},"page":"23-30","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Comparison of two models of biofilm formation on reusable stainless steel medical device material"],"prefix":"10.1016","volume":"168","author":[{"given":"G.G.","family":"Anderson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"James","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Kovvali","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.W.","family":"Dang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Vishwakarma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.-C.","family":"Gagnon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Goulet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Racine","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Labrie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Eppihimer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.W.","family":"Weeks","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Haas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Pandey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhin.2025.10.034_bib1","series-title":"Disinfection, sterilization, and preservation","first-page":"517","article-title":"Chemical disinfection of medical and surgical materials","author":"Spaulding","year":"1968"},{"key":"10.1016\/j.jhin.2025.10.034_bib2","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.jhin.2023.11.018","article-title":"A proposed cleaning classification system for reusable medical devices to complement the Spaulding classification","volume":"145","author":"Kremer","year":"2024","journal-title":"J Hosp Infect"},{"issue":"11S","key":"10.1016\/j.jhin.2025.10.034_bib3","doi-asserted-by":"crossref","first-page":"A114","DOI":"10.1016\/j.ajic.2023.04.158","article-title":"Biofilms on medical instruments and surfaces: do they interfere with instrument reprocessing and surface disinfection","volume":"51","author":"Weber","year":"2023","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2025.10.034_bib4","series-title":"Flexible and semi-rigid endoscope processing in health care facilities","year":"2021"},{"key":"10.1016\/j.jhin.2025.10.034_bib5","series-title":"Reprocessing medical devices in health care settings: validation methods and labeling; guidance for industry and food and drug administration staff","year":"2015"},{"key":"10.1016\/j.jhin.2025.10.034_bib6","series-title":"Processing of health care products \u2013 information to be provided by the medical device manufacturer for the processing of medical devices \u2013 Part 2: non-critical medical devices","year":"2021"},{"key":"10.1016\/j.jhin.2025.10.034_bib7","series-title":"Processing of health care products \u2013 information to be provided by the medical device manufacturer for the processing of medical devices \u2013 Part 1: critical and semi-critical medical devices","year":"2021"},{"key":"10.1016\/j.jhin.2025.10.034_bib8","series-title":"Cleaning validation of health care products \u2013 requirements for development and validation of a cleaning process for medical devices","year":"2022"},{"key":"10.1016\/j.jhin.2025.10.034_bib9","unstructured":"US Food & Drug Administration. Use duodenoscopes with innovative designs to enhance safety: FDA safety communication. Available at: https:\/\/www.fda.gov\/medical-devices\/safety-communications\/use-duodenoscopes-innovative-designs-enhance-safety-fda-safety-communication2022 [last accessed November 2025]."},{"issue":"5","key":"10.1016\/j.jhin.2025.10.034_bib10","doi-asserted-by":"crossref","DOI":"10.1128\/spectrum.01897-22","article-title":"High prevalence rate of microbial contamination in patient-ready gastrointestinal endoscopes in Tehran, Iran: an alarming sign for the occurrence of severe outbreaks","volume":"10","author":"Houri","year":"2022","journal-title":"Microbiol Spectr"},{"key":"10.1016\/j.jhin.2025.10.034_bib11","doi-asserted-by":"crossref","first-page":"e26","DOI":"10.1016\/j.ajic.2016.10.017","article-title":"Longitudinal assessment of reprocessing effectiveness for colonoscopes and gastroscopes: results of visual inspections, biochemical markers, and microbial cultures","volume":"45","author":"Ofstead","year":"2017","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2025.10.034_bib12","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/j.jhin.2017.07.012","article-title":"Endoscope drying and its pitfalls","volume":"97","author":"Kovaleva","year":"2017","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.10.034_bib13","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.jhin.2016.03.020","article-title":"Staphylococcus aureus dry-surface biofilms are not killed by sodium hypochlorite: implications for infection control","volume":"93","author":"Almatroudi","year":"2016","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.10.034_bib14","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.jhin.2017.09.007","article-title":"Staphylococcus aureus dry-surface biofilms are more resistant to heat treatment than traditional hydrated biofilms","volume":"98","author":"Almatroudi","year":"2018","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.10.034_bib15","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.ajic.2019.08.024","article-title":"Effectiveness of manual versus automated cleaning on Staphylococcus epidermidis biofilm removal from the surface of surgical instruments","volume":"48","author":"Evangelista","year":"2020","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2025.10.034_bib16","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.jhin.2022.03.011","article-title":"Hinged surgical instruments: efficacy of double manual cleaning versus automated cleaning on biofilm removal","volume":"124","author":"de Melo Costa","year":"2022","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.10.034_bib17","doi-asserted-by":"crossref","first-page":"917","DOI":"10.4187\/respcare.03513","article-title":"Device cleaning and infection control in aerosol therapy","volume":"60","author":"O\u2019Malley","year":"2015","journal-title":"Respir Care"},{"issue":"7","key":"10.1016\/j.jhin.2025.10.034_bib18","article-title":"Medical device-associated infections caused by biofilm-forming microbial pathogens and controlling strategies","volume":"13","author":"Mishra","year":"2024","journal-title":"Antibiotics (Basel)"},{"key":"10.1016\/j.jhin.2025.10.034_bib19","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1128\/CMR.00085-12","article-title":"Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy","volume":"26","author":"Kovaleva","year":"2013","journal-title":"Clin Microbiol Rev"},{"key":"10.1016\/j.jhin.2025.10.034_bib20","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.jcma.2017.07.012","article-title":"Bacterial biofilm and associated infections","volume":"81","author":"Jamal","year":"2018","journal-title":"J Chin Med Assoc"},{"key":"10.1016\/j.jhin.2025.10.034_bib21","doi-asserted-by":"crossref","DOI":"10.1016\/j.bioflm.2024.100210","article-title":"Global challenges and microbial biofilms: identification of priority questions in biofilm research, innovation and policy","volume":"8","author":"Coenye","year":"2024","journal-title":"Biofilm"},{"key":"10.1016\/j.jhin.2025.10.034_bib22","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1080\/1040841X.2016.1208146","article-title":"Critical review on biofilm methods","volume":"43","author":"Azeredo","year":"2017","journal-title":"Crit Rev Microbiol"},{"key":"10.1016\/j.jhin.2025.10.034_bib23","series-title":"Standard test method for quantification of Pseudomonas aeruginosa Biofilm grown with high shear and continuous flow using CDC Biofilm Reactor","year":"2022"},{"key":"10.1016\/j.jhin.2025.10.034_bib24","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1038\/nprot.2009.59","article-title":"A method for growing a biofilm under low shear at the air-liquid interface using the drip flow biofilm reactor","volume":"4","author":"Goeres","year":"2009","journal-title":"Nat Protoc"},{"key":"10.1016\/j.jhin.2025.10.034_bib25","series-title":"Standard test method for quantification of Pseudomonas aeruginosa biofilm grown using drip flow biofilm reactor with low shear and continuous flow","year":"2020"},{"key":"10.1016\/j.jhin.2025.10.034_bib26","doi-asserted-by":"crossref","first-page":"4223","DOI":"10.1128\/JB.00107-07","article-title":"Spatial patterns of DNA replication, protein synthesis, and oxygen concentration within bacterial biofilms reveal diverse physiological states","volume":"189","author":"Rani","year":"2007","journal-title":"J Bacteriol"},{"issue":"46","key":"10.1016\/j.jhin.2025.10.034_bib27","first-page":"2470","article-title":"The use of drip flow and rotating disk reactors for Staphylococcus aureus biofilm analysis","author":"Schwartz","year":"2010","journal-title":"J Vis Exp"},{"key":"10.1016\/j.jhin.2025.10.034_bib28","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/706189","article-title":"Continuous drip flow system to develop biofilm of E. faecalis under anaerobic conditions","volume":"2014","author":"Gonzalez","year":"2014","journal-title":"ScientificWorldJournal"},{"key":"10.1016\/j.jhin.2025.10.034_bib29","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-018-30706-0","article-title":"Modelling vaporised hydrogen peroxide efficacy against mono-species biofilms","volume":"8","author":"Watson","year":"2018","journal-title":"Sci Rep"},{"key":"10.1016\/j.jhin.2025.10.034_bib30","doi-asserted-by":"crossref","DOI":"10.3389\/fmicb.2023.1100607","article-title":"A Klebsiella pneumoniae NDM-1+ bacteriophage: adaptive polyvalence and disruption of heterogenous biofilms","volume":"14","author":"Gilcrease","year":"2023","journal-title":"Front Microbiol"},{"key":"10.1016\/j.jhin.2025.10.034_bib31","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.jhin.2014.11.019","article-title":"Pseudomonas aeruginosa in hospital water systems: biofilms, guidelines, and practicalities","volume":"89","author":"Walker","year":"2015","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.10.034_bib32","doi-asserted-by":"crossref","DOI":"10.1016\/j.bioflm.2023.100163","article-title":"Comparison of quantification methods for an endoscope lumen biofilm model","volume":"6","author":"Haas","year":"2023","journal-title":"Biofilm"},{"key":"10.1016\/j.jhin.2025.10.034_bib33","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/S0966-842X(00)01913-2","article-title":"Mechanisms of biofilm resistance to antimicrobial agents","volume":"9","author":"Mah","year":"2001","journal-title":"Trends Microbiol"},{"issue":"6","key":"10.1016\/j.jhin.2025.10.034_bib34","doi-asserted-by":"crossref","DOI":"10.1099\/mic.0.001340","article-title":"Biofilms as protective cocoons against biocides: from bacterial adaptation to One Health issues","volume":"169","author":"Charron","year":"2023","journal-title":"Microbiology (Reading)"},{"issue":"5","key":"10.1016\/j.jhin.2025.10.034_bib35","doi-asserted-by":"crossref","DOI":"10.3390\/pathogens13050393","article-title":"Medical device-associated biofilm infections and multidrug-resistant pathogens","volume":"13","author":"Bouhrour","year":"2024","journal-title":"Pathogens"},{"key":"10.1016\/j.jhin.2025.10.034_bib36","doi-asserted-by":"crossref","first-page":"A39","DOI":"10.1016\/j.ajic.2019.02.027","article-title":"Biofilms on instruments and environmental surfaces: do they interfere with instrument reprocessing and surface disinfection? Review of the literature","volume":"47S","author":"Alfa","year":"2019","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2025.10.034_bib37","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.gie.2019.08.043","article-title":"Impact of wet storage and other factors on biofilm formation and contamination of patient-ready endoscopes: a narrative review","volume":"91","author":"Alfa","year":"2020","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.jhin.2025.10.034_bib38","doi-asserted-by":"crossref","first-page":"277","DOI":"10.3201\/eid0702.010226","article-title":"Biofilms and device-associated infections","volume":"7","author":"Donlan","year":"2001","journal-title":"Emerg Infect Dis"},{"key":"10.1016\/j.jhin.2025.10.034_bib39","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.jhin.2004.06.023","article-title":"Is biofilm accumulation on endoscope tubing a contributor to the failure of cleaning and decontamination?","volume":"58","author":"Pajkos","year":"2004","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.10.034_bib40","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1016\/j.ajic.2014.07.029","article-title":"Correlation between the growth of bacterial biofilm in flexible endoscopes and endoscope reprocessing methods","volume":"42","author":"Ren-Pei","year":"2014","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.jhin.2025.10.034_bib41","doi-asserted-by":"crossref","first-page":"3257","DOI":"10.1021\/acs.jpcb.2c08785","article-title":"Elucidating the mechanism for the reaction of o-phthalaldehyde with primary amines in the presence of thiols","volume":"127","author":"Rovelli","year":"2023","journal-title":"J Phys Chem B"}],"container-title":["Journal of Hospital Infection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S019567012500355X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S019567012500355X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T10:19:35Z","timestamp":1773915575000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S019567012500355X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":41,"alternative-id":["S019567012500355X"],"URL":"https:\/\/doi.org\/10.1016\/j.jhin.2025.10.034","relation":{},"ISSN":["0195-6701"],"issn-type":[{"value":"0195-6701","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of two models of biofilm formation on reusable stainless steel medical device material","name":"articletitle","label":"Article Title"},{"value":"Journal of Hospital Infection","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhin.2025.10.034","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Published by Elsevier Ltd on behalf of The Healthcare Infection Society.","name":"copyright","label":"Copyright"}]}}