{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T02:29:41Z","timestamp":1777861781583,"version":"3.51.4"},"reference-count":15,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T00:00:00Z","timestamp":1765929600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002329","name":"Bundesamt f\u00fcr Gesundheit","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002329","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journalofhospitalinfection.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hospital Infection"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1016\/j.jhin.2025.12.004","type":"journal-article","created":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T17:06:27Z","timestamp":1766163987000},"page":"93-97","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Simulated use of the water circuit disinfection device on a Mycobacterium chimaera\u2013contaminated LivaNova 3T Heater Cooler Device: results of mycobacterial and bacterial surveillance"],"prefix":"10.1016","volume":"169","author":[{"given":"C.","family":"Reiber","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Aigner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Chakrakodi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Dunic","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Ernst","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Pfister","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Klapproth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"van Tilburg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Imkamp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Schulthess","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Sander","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.D.","family":"Brugger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Rodriguez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"O.","family":"Dzemali","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W.","family":"Zingg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8123-2601","authenticated-orcid":false,"given":"P.W.","family":"Schreiber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhin.2025.12.004_bib1","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1097\/QCO.0000000000000385","article-title":"Mycobacterium chimaera infections associated with heater-cooler units in cardiac surgery","volume":"30","author":"Schreiber","year":"2017","journal-title":"Curr Opin Infect Dis"},{"key":"10.1016\/j.jhin.2025.12.004_bib2","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1093\/cid\/civ198","article-title":"Prolonged outbreak of Mycobacterium chimaera infection after open-chest heart surgery","volume":"61","author":"Sax","year":"2015","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.jhin.2025.12.004_bib3","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.3201\/eid2206.160045","article-title":"Transmission of Mycobacterium chimaera from heater-cooler units during cardiac surgery despite an ultraclean air ventilation system","volume":"22","author":"Sommerstein","year":"2016","journal-title":"Emerg Infect Dis"},{"key":"10.1016\/j.jhin.2025.12.004_bib4","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/S1473-3099(17)30324-9","article-title":"Global outbreak of severe Mycobacterium chimaera disease after cardiac surgery: a molecular epidemiological study","volume":"17","author":"van Ingen","year":"2017","journal-title":"Lancet Infect Dis"},{"key":"10.1016\/j.jhin.2025.12.004_bib5","doi-asserted-by":"crossref","DOI":"10.2807\/1560-7917.ES.2016.21.17.30215","article-title":"Contamination during production of heater-cooler units by Mycobacterium chimaera potential cause for invasive cardiovascular infections: results of an outbreak investigation in Germany, April 2015 to February 2016","volume":"21","author":"Haller","year":"2016","journal-title":"Euro Surveill"},{"key":"10.1016\/j.jhin.2025.12.004_bib6","doi-asserted-by":"crossref","first-page":"1613","DOI":"10.1016\/j.cmi.2021.07.017","article-title":"The global outbreak of Mycobacterium chimaera infections in cardiac surgery-a systematic review of whole-genome sequencing studies and joint analysis","volume":"27","author":"Schreiber","year":"2021","journal-title":"Clin Microbiol Infect"},{"key":"10.1016\/j.jhin.2025.12.004_bib7","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.jhin.2017.04.014","article-title":"Microbiological problems and biofilms associated with Mycobacterium chimaera in heater-cooler units used for cardiopulmonary bypass","volume":"96","author":"Walker","year":"2017","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.12.004_bib8","doi-asserted-by":"crossref","first-page":"1830","DOI":"10.3201\/eid2210.160925","article-title":"Reemergence of Mycobacterium chimaera in heater-cooler units despite intensified cleaning and disinfection protocol","volume":"22","author":"Schreiber","year":"2016","journal-title":"Emerg Infect Dis"},{"key":"10.1016\/j.jhin.2025.12.004_bib9","doi-asserted-by":"crossref","DOI":"10.1016\/j.jhin.2020.03.006","article-title":"Diversity of non-tuberculous mycobacteria in heater-cooler devices - results from prospective surveillance","author":"Kaelin","year":"2020","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.12.004_bib10","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.jhin.2022.11.003","article-title":"Longitudinal increase in the detection rate of Mycobacterium chimaera in heater-cooler device-derived water samples","volume":"131","author":"Schreiber","year":"2023","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.12.004_bib11","series-title":"Anweisung zur Inbetriebnahme f\u00fcr geschultes Personal","year":"2022"},{"key":"10.1016\/j.jhin.2025.12.004_bib12","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1177\/02676591211033483","article-title":"A solution for global hygienic challenges regarding the application of heater-cooler systems in cardiac surgery","volume":"38","author":"Foltan","year":"2023","journal-title":"Perfusion"},{"key":"10.1016\/j.jhin.2025.12.004_bib13","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.jhin.2017.11.007","article-title":"Detection limit of Mycobacterium chimaera in water samples for monitoring medical device safety: insights from a pilot experimental series","volume":"99","author":"Schreiber","year":"2018","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.jhin.2025.12.004_bib14","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1186\/s13756-019-0546-y","article-title":"Bacterial colonization of handheld devices in a tertiary care setting: a hygiene intervention study","volume":"8","author":"Frey","year":"2019","journal-title":"Antimicrob Resist Infect Control"},{"key":"10.1016\/j.jhin.2025.12.004_bib15","doi-asserted-by":"crossref","first-page":"i2","DOI":"10.1093\/jac\/dkae275","article-title":"Evolving strategies in microbe identification-a comprehensive review of biochemical, MALDI-TOF MS and molecular testing methods","volume":"79","author":"Arbefeville","year":"2024","journal-title":"J Antimicrob Chemother"}],"container-title":["Journal of Hospital Infection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670125004256?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0195670125004256?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T05:02:56Z","timestamp":1777525376000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0195670125004256"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":15,"alternative-id":["S0195670125004256"],"URL":"https:\/\/doi.org\/10.1016\/j.jhin.2025.12.004","relation":{},"ISSN":["0195-6701"],"issn-type":[{"value":"0195-6701","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Simulated use of the water circuit disinfection device on a Mycobacterium chimaera\u2013contaminated LivaNova 3T Heater Cooler Device: results of mycobacterial and bacterial surveillance","name":"articletitle","label":"Article Title"},{"value":"Journal of Hospital Infection","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhin.2025.12.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier Ltd on behalf of The Healthcare Infection Society.","name":"copyright","label":"Copyright"}]}}