{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T14:51:53Z","timestamp":1790520713309,"version":"4.1.0"},"reference-count":19,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,11,17]],"date-time":"2023-11-17T00:00:00Z","timestamp":1700179200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["jhltopen.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JHLT Open"],"published-print":{"date-parts":[[2024,2]]},"DOI":"10.1016\/j.jhlto.2023.100025","type":"journal-article","created":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T22:33:25Z","timestamp":1700346805000},"page":"100025","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"special_numbering":"C","title":["Carboxyhemoglobin and methemoglobin levels to diagnose hemolysis in patients supported with mechanical circulatory support devices"],"prefix":"10.1016","volume":"3","author":[{"given":"Ingrid L.","family":"Rodgers","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel S.","family":"Yip","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parag C.","family":"Patel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cesar A.","family":"Keller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhlto.2023.100025_bib1","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1161\/CIRCULATIONAHA.106.613596","article-title":"Cardiogenic shock: current concepts and improving outcomes","volume":"117","author":"Reynolds","year":"2008","journal-title":"Circulation"},{"key":"10.1016\/j.jhlto.2023.100025_bib2","doi-asserted-by":"crossref","first-page":"e232","DOI":"10.1161\/CIR.0000000000000525","article-title":"Contemporary management of cardiogenic shock. A scientific statement from the American Heart Association","volume":"136","author":"Van Diepen","year":"2017","journal-title":"Circulation"},{"key":"10.1016\/j.jhlto.2023.100025_bib3","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/0002-9149(67)90023-9","article-title":"Treatment of myocardial infarction in a coronary care unit. A two-year experience with 250 patients","volume":"20","author":"Killip","year":"1967","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jhlto.2023.100025_bib4","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.athoracsur.2013.07.053","article-title":"The Impella device for acute mechanical circulatory support in patients with cardiogenic shock","volume":"97","author":"Lemaire","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jhlto.2023.100025_bib5","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s11897-013-0132-1","article-title":"Defining the role for percutaneous mechanical circulatory support devices for medically refractory heart failure","volume":"10","author":"Kapur","year":"2013","journal-title":"Curr Heart Failure Rep"},{"key":"10.1016\/j.jhlto.2023.100025_bib6","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/MAT.0000000000000290","article-title":"Incidence of hemolysis in patients with cardiogenic shock treated with Impella percutaneous left ventricular assist device","volume":"62","author":"Badiye","year":"2016","journal-title":"ASAIO J"},{"key":"10.1016\/j.jhlto.2023.100025_bib7","first-page":"354","article-title":"Hemolytic anemia: evaluation and differential diagnosis","volume":"98","author":"Phillips","year":"2018","journal-title":"Am Fam Physician"},{"key":"10.1016\/j.jhlto.2023.100025_bib8","doi-asserted-by":"crossref","DOI":"10.1155\/2015\/635670","article-title":"Clinical applications of hemolytic markers in the differential diagnosis and management of hemolytic anemia","volume":"2015","author":"Barcellini","year":"2015","journal-title":"Dis Markers"},{"key":"10.1016\/j.jhlto.2023.100025_bib9","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1172\/JCI105360","article-title":"Endogenous carbon monoxide production in patients with hemolytic anemia","volume":"45","author":"Coburn","year":"1966","journal-title":"J Clin Invest"},{"key":"10.1016\/j.jhlto.2023.100025_bib10","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0124034","article-title":"Plasma free hemoglobin is an independent predictor of mortality among patients on extracorporeal membrane oxygenation support","volume":"10","author":"Omar","year":"2015","journal-title":"PLoS One"},{"key":"10.1016\/j.jhlto.2023.100025_bib11","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1177\/2150135113509818","article-title":"Hyperbilirubinemia complicating plasma-free hemoglobin and antifactor Xa level monitoring on venovenous extracorporeal membrane oxygenation","volume":"5","author":"Hayes","year":"2014","journal-title":"World J Ped Cong Heart Surg"},{"key":"10.1016\/j.jhlto.2023.100025_bib12","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1164\/rccm.201606-1275CI","article-title":"Carbon monoxide poisoning: pathogenesis, management and future directions of therapy","volume":"195","author":"Rose","year":"2017","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1016\/j.jhlto.2023.100025_bib13","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.jemermed.2006.10.004","article-title":"Carboxyhemoglobin elevation due to hemolytic anemia","volume":"33","author":"Hampson","year":"2007","journal-title":"J Emerg Med"},{"key":"10.1016\/j.jhlto.2023.100025_bib14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13054-020-03437-w","article-title":"Carboxyhemoglobin, a reliable diagnosis biomarker for hemolysis in intensive care unit: a retrospective study","volume":"25","author":"Hariri","year":"2021","journal-title":"Crit Care"},{"key":"10.1016\/j.jhlto.2023.100025_bib15","doi-asserted-by":"crossref","first-page":"1642","DOI":"10.3390\/diagnostics12071642","article-title":"Carboxyhemoglobin (CO-Hb) correlates with hemolysis and hospital mortality in extracorporeal membrane oxygenation: a retrospective registry","volume":"12","author":"Bemgten","year":"2022","journal-title":"Diagnostics"},{"key":"10.1016\/j.jhlto.2023.100025_bib16","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1097\/00000441-198505000-00004","article-title":"Review: methemoglobinemia","volume":"289","author":"Mansouri","year":"1985","journal-title":"Am J Med Sci"},{"key":"10.1016\/j.jhlto.2023.100025_bib17","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1177\/0391398820932175","article-title":"Hemolysis and methemoglobinemia in a child with left ventricular assist Levitronix PediMag","volume":"44","author":"Laiseca","year":"2021","journal-title":"Int J Art Org"},{"key":"10.1016\/j.jhlto.2023.100025_bib18","series-title":"Murray and Nadel\u2019s Textbook of Respiratory Medicine","article-title":"Pulmonary function testing: physiologic and technical principles","author":"Bhakta","year":"2021"},{"key":"10.1016\/j.jhlto.2023.100025_bib19","doi-asserted-by":"crossref","first-page":"66","DOI":"10.3410\/M1-66","article-title":"Recent advances in pulse oximetry","volume":"1","author":"Canneson","year":"2009","journal-title":"F1000 Med Rep"}],"container-title":["JHLT Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2950133423000253?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2950133423000253?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T16:19:39Z","timestamp":1757434779000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2950133423000253"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2]]},"references-count":19,"alternative-id":["S2950133423000253"],"URL":"https:\/\/doi.org\/10.1016\/j.jhlto.2023.100025","relation":{},"ISSN":["2950-1334"],"issn-type":[{"value":"2950-1334","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Carboxyhemoglobin and methemoglobin levels to diagnose hemolysis in patients supported with mechanical circulatory support devices","name":"articletitle","label":"Article Title"},{"value":"JHLT Open","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhlto.2023.100025","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Inc. on behalf of International Society for Heart and Lung Transplantation.","name":"copyright","label":"Copyright"}],"article-number":"100025"}}