{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T08:46:35Z","timestamp":1772181995788,"version":"3.50.1"},"reference-count":22,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2008,3,1]],"date-time":"2008-03-01T00:00:00Z","timestamp":1204329600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Hand Surgery"],"published-print":{"date-parts":[[2008,3]]},"DOI":"10.1016\/j.jhsa.2007.09.019","type":"journal-article","created":{"date-parts":[[2008,3,15]],"date-time":"2008-03-15T10:58:19Z","timestamp":1205578699000},"page":"322-326","source":"Crossref","is-referenced-by-count":11,"title":["Biomechanical Characteristics of Nonbridging External Fixators for Distal Radius Fractures"],"prefix":"10.1016","volume":"33","author":[{"given":"Go","family":"Yamako","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinori","family":"Ishii","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshikazu","family":"Matsuda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hideo","family":"Noguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiaki","family":"Hara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhsa.2007.09.019_bib1","first-page":"181","article-title":"On the fracture of the carpal extremity of the radius","volume":"10","author":"Colles","year":"1814","journal-title":"Edinb Med Surg J"},{"issue":"Suppl","key":"10.1016\/j.jhsa.2007.09.019_bib2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3109\/ort.1959.30.suppl-41.01","article-title":"Fractures of the distal end of the radius","volume":"41","author":"Lidstrom","year":"1959","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.jhsa.2007.09.019_bib3","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/S0363-5023(97)80159-1","article-title":"Percutaneous pinning of distal radius fractures: a biomechanical study","volume":"22A","author":"Naidu","year":"1997","journal-title":"J Hand Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib4","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1016\/S0363-5023(98)80175-5","article-title":"Load relaxation and forces with activity in Hoffman external fixators: a clinical study in patients with Colles\u2019 fractures","volume":"23A","author":"Winemaker","year":"1998","journal-title":"J Hand Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib5","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1097\/00005131-199506000-00004","article-title":"A biomechanical comparison of two methods of fixation of fractures of the forearm","volume":"9","author":"Jones","year":"1995","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.jhsa.2007.09.019_bib6","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1053\/jhsu.1999.0816","article-title":"Augmentation of distal radius fracture fixation with coralline hydroxyapatite bone graft substitute","volume":"24A","author":"Wolfe","year":"1999","journal-title":"J Hand Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib7","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1302\/0301-620X.78B4.0780588","article-title":"Fractures of the distal end of the radius treated by internal fixation and early function: a preliminary report of 20 cases","volume":"78B","author":"Rikli","year":"1996","journal-title":"J Bone Joint Surg"},{"issue":"3","key":"10.1016\/j.jhsa.2007.09.019_bib8","article-title":"Surgical interventions for treating distal radial fractures in adults","author":"Handoll","year":"2003","journal-title":"Cochrane Database Syst Rev"},{"key":"10.1016\/j.jhsa.2007.09.019_bib9","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.2106\/00004623-199408000-00005","article-title":"Dynamic external fixation of unstable fractures of the distal part of the radius","volume":"76A","author":"Sommerkamp","year":"1994","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib10","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1302\/0301-620X.80B4.8150","article-title":"Redisplaced unstable fractures of the distal radius","volume":"80B","author":"McQueen","year":"1998","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib11","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1007\/s00776-004-0828-x","article-title":"Comparative study of non-bridging and bridging external fixators for unstable distal radius fractures","volume":"9","author":"Uchikura","year":"2004","journal-title":"J Orthop Sci"},{"key":"10.1016\/j.jhsa.2007.09.019_bib12","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1080\/17453670610046389","article-title":"Wrist-bridging versus non-bridging external fixation for displaced distal radius fractures","volume":"77","author":"Atroshi","year":"2006","journal-title":"Acta Orthop"},{"key":"10.1016\/j.jhsa.2007.09.019_bib13","first-page":"40","article-title":"Biomechanical comparison of five external wrist fixators","volume":"61","author":"Chang","year":"2003","journal-title":"Bull Hosp Joint Dis 2002\u2013"},{"key":"10.1016\/j.jhsa.2007.09.019_bib14","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1016\/0363-5023(92)90417-N","article-title":"Force distribution across wrist joint: application of pressure-sensitive conductive rubber","volume":"17A","author":"Hara","year":"1992","journal-title":"J Hand Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib15","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1097\/00005373-199806000-00006","article-title":"A biomechanical strength comparison of external fixators","volume":"44","author":"Sladicka","year":"1998","journal-title":"J Trauma"},{"key":"10.1016\/j.jhsa.2007.09.019_bib16","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.jhsa.2003.12.010","article-title":"Biomechanics in uniaxial compression of three distal radius volar plates","volume":"29A","author":"Osada","year":"2004","journal-title":"J Hand Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib17","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1302\/0301-620X.67B4.4030869","article-title":"The influence of induced micromovement upon the healing of experimental tibial fractures","volume":"67B","author":"Goodship","year":"1985","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib18","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1097\/00003086-200107000-00033","article-title":"Effect of early axial dynamization on tibial bone healing","volume":"388","author":"Larsson","year":"2001","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.jhsa.2007.09.019_bib19","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/S0363-5023(87)80202-2","article-title":"A biomechanical and clinical study of distal radial fractures","volume":"12A","author":"Short","year":"1987","journal-title":"J Hand Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0363-5023(88)90189-X","article-title":"Relative motion of selected carpal bones: a kinematic analysis of the normal wrist","volume":"13A","author":"Ruby","year":"1988","journal-title":"J Hand Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib21","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1016\/S0363-5023(87)80065-5","article-title":"The effect of scapholunate ligament section on scapholunate motion","volume":"12A","author":"Ruby","year":"1987","journal-title":"J Hand Surg"},{"key":"10.1016\/j.jhsa.2007.09.019_bib22","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1053\/jhsu.1999.0365","article-title":"A biomechanical comparison of different wrist external fixators with and without K-wire augmentation","volume":"24A","author":"Wolfe","year":"1999","journal-title":"J Hand Surg"}],"container-title":["The Journal of Hand Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0363502307010969?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0363502307010969?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,5,9]],"date-time":"2019-05-09T00:15:08Z","timestamp":1557360908000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0363502307010969"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,3]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2008,3]]}},"alternative-id":["S0363502307010969"],"URL":"https:\/\/doi.org\/10.1016\/j.jhsa.2007.09.019","relation":{},"ISSN":["0363-5023"],"issn-type":[{"value":"0363-5023","type":"print"}],"subject":[],"published":{"date-parts":[[2008,3]]}}}