{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T23:37:07Z","timestamp":1790552227718,"version":"4.1.0"},"reference-count":29,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2010,1,1]],"date-time":"2010-01-01T00:00:00Z","timestamp":1262304000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Hand Surgery"],"published-print":{"date-parts":[[2010,1]]},"DOI":"10.1016\/j.jhsa.2009.10.029","type":"journal-article","created":{"date-parts":[[2009,12,26]],"date-time":"2009-12-26T09:06:19Z","timestamp":1261818379000},"page":"141-143","source":"Crossref","is-referenced-by-count":8,"title":["Distal Radius Fractures and Titanium Volar Plates: Should We Take the Plates Out?"],"prefix":"10.1016","volume":"35","author":[{"given":"David G.","family":"Dennison","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jhsa.2009.10.029_bib1","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.jhsa.2003.09.015","article-title":"Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient","volume":"29A","author":"Orbay","year":"2004","journal-title":"J Hand Surg"},{"key":"10.1016\/j.jhsa.2009.10.029_bib2","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jhsa.2005.10.010","article-title":"Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius","volume":"31A","author":"Rozental","year":"2006","journal-title":"J Hand Surg"},{"key":"10.1016\/j.jhsa.2009.10.029_bib3","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1053\/adpa.2003.50006","article-title":"Prosthetic implant associated sarcomas: a case report emphasizing surface evaluation and spectroscopic trace metal analysis","volume":"7","author":"Adams","year":"2003","journal-title":"Ann Diagn Pathol"},{"key":"10.1016\/j.jhsa.2009.10.029_bib4","doi-asserted-by":"crossref","first-page":"1052","DOI":"10.14219\/jada.archive.2008.0307","article-title":"Maxillary osteosarcoma associated with a dental implant: report of a case and review of the literature regarding implant-related sarcomas","volume":"139","author":"McGuff","year":"2008","journal-title":"J Am Dent Assoc"},{"key":"10.1016\/j.jhsa.2009.10.029_bib5","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/0272-0590(89)90257-1","article-title":"Carcinogenicity of metal alloys in orthopedic prostheses: clinical and experimental studies","volume":"13","author":"Sunderman","year":"1989","journal-title":"Fundam Appl Toxicol"},{"key":"10.1016\/j.jhsa.2009.10.029_bib6","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/S0883-5403(05)80103-2","article-title":"Intraarticular carcinogenesis bioassays of CoCrMo and TiAIV alloys in rats","volume":"10","author":"Lewis","year":"1995","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.jhsa.2009.10.029_bib7","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1002\/jbm.820280508","article-title":"Evaluation of carcinogenicity and chronic toxicity associated with orthopedic implants in mice","volume":"28","author":"Takamura","year":"1994","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.jhsa.2009.10.029_bib8","series-title":"Particular debris from medical implants: mechanisms of formation and biological consequences","first-page":"177","article-title":"Preparation, characterization, and animal testing for biocompatibility of metal particles of iron-, cobalt-, titanium-based implant alloys","author":"Buchhorn","year":"1992"},{"key":"10.1016\/j.jhsa.2009.10.029_bib9","first-page":"1","article-title":"Corrosion of surgical implants - in vivo and in vitro tests","volume":"Vol. 1","author":"Steinemann","year":"1980"},{"key":"10.1016\/j.jhsa.2009.10.029_bib10","doi-asserted-by":"crossref","first-page":"2053","DOI":"10.1007\/s10856-007-3116-4","article-title":"Microvasculatory reaction of skeletal muscle to Ti-15Mo in comparison to well-established titanium alloys","volume":"18","author":"Pennekamp","year":"2007","journal-title":"J Mater Sci Mater Med"},{"key":"10.1016\/j.jhsa.2009.10.029_bib11","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1302\/0301-620X.86B4.14368","article-title":"Wear debris from hip or knee replacements cause chromosomal damage in human cells in tissue culture","volume":"86B","author":"Daley","year":"2004","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.jhsa.2009.10.029_bib12","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1002\/jor.1100150510","article-title":"Prosthetic metals impair murine immune response and cytokine release in vivo and in vitro","volume":"15","author":"Wang","year":"1997","journal-title":"J Orthop Res"},{"key":"10.1016\/j.jhsa.2009.10.029_bib13","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.arth.2004.09.012","article-title":"Immune response correlate with serum-metal in metal-on-metal hip arthroplasty","volume":"19","author":"Hallab","year":"2004","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.jhsa.2009.10.029_bib14","series-title":"Titanium alloys in surgical implants","first-page":"206","article-title":"Surface preparation and corrosion behavior of titanium alloys for surgical implants","author":"Fraker","year":"1983"},{"key":"10.1016\/j.jhsa.2009.10.029_bib15","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1002\/jbm.820170308","article-title":"In vitro electrochemical corrosion study of coupled surgical implant materials","volume":"17","author":"Griffin","year":"1983","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.jhsa.2009.10.029_bib16","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.injury.2007.07.015","article-title":"Should the galvanic combination of titanium and stainless steel surgical implants be avoided?","volume":"39","author":"H\u00f8l","year":"2008","journal-title":"Injury"},{"key":"10.1016\/j.jhsa.2009.10.029_bib17","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1002\/jbm.820080609","article-title":"Couple corrosion among alloys for skeletal prostheses","volume":"8","author":"Rostoker","year":"1974","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.jhsa.2009.10.029_bib18","first-page":"35","article-title":"Titanium and stainless steel and their combination in bone surgery","volume":"Vol. 2","author":"R\u00fcedi","year":"1980"},{"key":"10.1016\/j.jhsa.2009.10.029_bib19","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1016\/S0142-9612(98)00225-7","article-title":"Biologic response to passive dissolution of titanium craniofacial microplates","volume":"20","author":"Jorgenson","year":"1999","journal-title":"Biomaterials"},{"key":"10.1016\/j.jhsa.2009.10.029_bib20","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/S0901-5027(05)80249-8","article-title":"Should titanium miniplates be removed after bone healing is complete?","volume":"22","author":"Rosenberg","year":"1993","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.jhsa.2009.10.029_bib21","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s11999-008-0540-9","article-title":"2008 John Charnley Award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial","volume":"467","author":"Engh","year":"2009","journal-title":"Clin Orthop"},{"key":"10.1016\/j.jhsa.2009.10.029_bib22","doi-asserted-by":"crossref","first-page":"168","DOI":"10.3109\/17453670902947408","article-title":"Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis","volume":"80","author":"Lazennec","year":"2009","journal-title":"Acta Orthop"},{"key":"10.1016\/j.jhsa.2009.10.029_bib23","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.arth.2006.05.005","article-title":"Serum metal levels and bearing surface in total hip arthroplasty","volume":"21","author":"Rasquinha","year":"2006","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.jhsa.2009.10.029_bib24","doi-asserted-by":"crossref","first-page":"1569","DOI":"10.1002\/jor.20701","article-title":"Serum ion levels after ceramic-on-ceramic and metal-on-metal total hip arthroplasty: 8-year minimum follow-up","volume":"26","author":"Savarino","year":"2008","journal-title":"J Orthop Res"},{"key":"10.1016\/j.jhsa.2009.10.029_bib25","doi-asserted-by":"crossref","first-page":"1937","DOI":"10.1016\/0142-9612(96)00023-3","article-title":"Titanium serum and urine levels in rabbits with a titanium implant in the absence of wear","volume":"17","author":"Bianco","year":"1996","journal-title":"Biomaterials"},{"key":"10.1016\/j.jhsa.2009.10.029_bib26","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1080\/17453670810016911","article-title":"Levels of systemic metal ions in patients with intramedullary nails","volume":"79","author":"Patton","year":"2008","journal-title":"Acta Orthop"},{"key":"10.1016\/j.jhsa.2009.10.029_bib27","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1097\/01.ta.0000240445.20220.54","article-title":"Serum titanium levels in individuals undergoing intramedullary femoral nailing with a titanium implant","volume":"64","author":"McGarry","year":"2008","journal-title":"J Trauma"},{"key":"10.1016\/j.jhsa.2009.10.029_bib28","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1097\/01.BRS.0000065482.41115.B4","article-title":"Metal concentration in the serum and hair of patients with titanium alloy spinal implants","volume":"28","author":"Kasai","year":"2003","journal-title":"Spine"},{"key":"10.1016\/j.jhsa.2009.10.029_bib29","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1515\/BMT.2006.006","article-title":"Titanium serum levels may remain elevated despite hip revision surgery for wear-through of an acetabular component","volume":"51","author":"Quitmann","year":"2006","journal-title":"Biomed Tech (Berl)"}],"container-title":["The Journal of Hand Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0363502309009332?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0363502309009332?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T20:39:07Z","timestamp":1558730347000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0363502309009332"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["S0363502309009332"],"URL":"https:\/\/doi.org\/10.1016\/j.jhsa.2009.10.029","relation":{},"ISSN":["0363-5023"],"issn-type":[{"value":"0363-5023","type":"print"}],"subject":[],"published":{"date-parts":[[2010,1]]}}}