{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T08:49:36Z","timestamp":1790412576892,"version":"4.1.0"},"reference-count":8,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2019,2,1]],"date-time":"2019-02-01T00:00:00Z","timestamp":1548979200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Hand Surgery"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1016\/j.jhsa.2018.04.009","type":"journal-article","created":{"date-parts":[[2018,6,18]],"date-time":"2018-06-18T22:56:51Z","timestamp":1529362611000},"page":"163.e1-163.e5","source":"Crossref","is-referenced-by-count":30,"title":["A Novel Muscle Transfer for Independent Digital Control of a Myoelectric Prosthesis: The Starfish Procedure"],"prefix":"10.1016","volume":"44","author":[{"given":"R. Glenn","family":"Gaston","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1409-1436","authenticated-orcid":false,"given":"John W.","family":"Bracey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark A.","family":"Tait","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryan J.","family":"Loeffler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.jhsa.2018.04.009_bib1","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1109\/TNSRE.2014.2305111","article-title":"The extraction of neural information from the surface emg for the control of upper-limb prostheses: Emerging avenues and challenges","volume":"22","author":"Farina","year":"2014","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"6","key":"10.1016\/j.jhsa.2018.04.009_bib2","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1016\/0013-4694(88)90169-1","article-title":"Surface myoelectric signal cross-talk among muscles of the leg","volume":"69","author":"De Luca","year":"1988","journal-title":"Electroencephalogr Clin Neurophysiol"},{"issue":"1","key":"10.1016\/j.jhsa.2018.04.009_bib3","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.pmrj.2010.06.016","article-title":"Neural interfaces for control of upper limb prostheses: the state of the art and future possibilities","volume":"3","author":"Schultz","year":"2011","journal-title":"PM R"},{"issue":"5","key":"10.1016\/j.jhsa.2018.04.009_bib4","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1109\/TBME.2008.2005485","article-title":"Decoding of individuated finger movements using surface electromyography","volume":"56","author":"Tenore","year":"2009","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.jhsa.2018.04.009_bib5","doi-asserted-by":"crossref","first-page":"162","DOI":"10.3389\/fnsys.2015.00162","article-title":"Control capabilities of myoelectric robotic prostheses by hand amputees: a scientific research and market overview","volume":"9","author":"Atzori","year":"2015","journal-title":"Front Syst Neurosci"},{"issue":"3","key":"10.1016\/j.jhsa.2018.04.009_bib6","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1097\/PRS.0b013e3181b038c9","article-title":"Targeted reinnervation for transhumeral amputees: current surgical technique and update on results","volume":"124","author":"Dumanian","year":"2009","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.jhsa.2018.04.009_bib7","first-page":"1350","article-title":"Implantable multichannel wireless electromyography for prosthesis control","volume":"2012","author":"McDonnall","year":"2012","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"issue":"1","key":"10.1016\/j.jhsa.2018.04.009_bib8","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/PRS.0000000000001926","article-title":"Prosthesis control with an implantable multichannel wireless electromyography system for high-level amputees: a large-animal study","volume":"137","author":"Bergmeister","year":"2016","journal-title":"Plast Reconstr Surg"}],"container-title":["The Journal of Hand Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0363502317314429?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0363502317314429?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,1,31]],"date-time":"2019-01-31T20:37:07Z","timestamp":1548967027000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0363502317314429"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2]]},"references-count":8,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["S0363502317314429"],"URL":"https:\/\/doi.org\/10.1016\/j.jhsa.2018.04.009","relation":{},"ISSN":["0363-5023"],"issn-type":[{"value":"0363-5023","type":"print"}],"subject":[],"published":{"date-parts":[[2019,2]]}}}