{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T02:44:18Z","timestamp":1768790658410,"version":"3.49.0"},"reference-count":21,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.fr","jhandsurg.org","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Hand Surgery"],"published-print":{"date-parts":[[2025,1]]},"DOI":"10.1016\/j.jhsa.2023.04.021","type":"journal-article","created":{"date-parts":[[2023,6,22]],"date-time":"2023-06-22T13:09:40Z","timestamp":1687439380000},"page":"99.e1-99.e5","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Changes in Distance Between the Flexor Pollicis Longus Tendon and Volar Locking Plate: An Ultrasonographic Study"],"prefix":"10.1016","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0938-6635","authenticated-orcid":false,"given":"Keiichiro","family":"Oura","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobumasa","family":"Matsumura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryosuke","family":"Noguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsuji","family":"Fujiwara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.jhsa.2023.04.021_bib1","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1142\/S0218810400000223","article-title":"The treatment of unstable distal radius fractures with volar fixation","volume":"5","author":"Orbay","year":"2000","journal-title":"Hand Surg"},{"issue":"4","key":"10.1016\/j.jhsa.2023.04.021_bib2","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/j.jhsa.2006.01.011","article-title":"Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction--a biomechanic study in a cadaveric model","volume":"31","author":"Drobetz","year":"2006","journal-title":"J\u00a0Hand Surg Am"},{"issue":"9","key":"10.1016\/j.jhsa.2023.04.021_bib3","doi-asserted-by":"crossref","first-page":"2051","DOI":"10.2106\/00004623-200709000-00025","article-title":"Management of distal radial fractures","volume":"89","author":"Chen","year":"2007","journal-title":"J\u00a0Bone Joint Surg Am"},{"issue":"1-2","key":"10.1016\/j.jhsa.2023.04.021_bib4","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1142\/S0218810406003048","article-title":"Delayed rupture of flexor pollicis longus tendon after volar plating of the distal radius","volume":"11","author":"Koo","year":"2006","journal-title":"Hand Surg"},{"issue":"5","key":"10.1016\/j.jhsa.2023.04.021_bib5","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/BOT.0b013e318059b993","article-title":"Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate","volume":"21","author":"Arora","year":"2007","journal-title":"J\u00a0Orthop Trauma"},{"issue":"12","key":"10.1016\/j.jhsa.2023.04.021_bib6","first-page":"669","article-title":"Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius","volume":"36","author":"Duncan","year":"2007","journal-title":"Am J Orthop (Belle Mead NJ)"},{"issue":"2","key":"10.1016\/j.jhsa.2023.04.021_bib7","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.jhsa.2007.11.011","article-title":"Flexor tendon injuries following locked volar plating of distal radius fractures","volume":"33","author":"Cross","year":"2008","journal-title":"J\u00a0Hand Surg Am"},{"issue":"6","key":"10.1016\/j.jhsa.2023.04.021_bib8","doi-asserted-by":"crossref","first-page":"369","DOI":"10.5435\/00124635-200906000-00005","article-title":"Complications of volar plate fixation for managing distal radius fractures","volume":"17","author":"Berglund","year":"2009","journal-title":"J\u00a0Am Acad Orthop Surg"},{"issue":"4","key":"10.1016\/j.jhsa.2023.04.021_bib9","doi-asserted-by":"crossref","first-page":"325","DOI":"10.4055\/cios.2012.4.4.325","article-title":"Delayed rupture of flexor pollicis longus after volar plating for a distal radius fracture","volume":"4","author":"Cho","year":"2012","journal-title":"Clin Orthop Surg"},{"issue":"4","key":"10.1016\/j.jhsa.2023.04.021_bib10","doi-asserted-by":"crossref","first-page":"328","DOI":"10.2106\/JBJS.J.00193","article-title":"Volar locking plate implant prominence and flexor tendon rupture","volume":"93","author":"Soong","year":"2011","journal-title":"J\u00a0Bone Joint Surg Am"},{"issue":"6","key":"10.1016\/j.jhsa.2023.04.021_bib11","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1053\/jhsu.1999.1279","article-title":"Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius","volume":"24","author":"Nunley","year":"1999","journal-title":"J\u00a0Hand Surg Am"},{"issue":"1","key":"10.1016\/j.jhsa.2023.04.021_bib12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00264-002-0393-x","article-title":"Osteosynthesis of distal radial fractures with a volar locking screw plate system","volume":"27","author":"Drobetz","year":"2003","journal-title":"Int Orthop"},{"issue":"2","key":"10.1016\/j.jhsa.2023.04.021_bib13","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1302\/0301-620X.80B2.0800225","article-title":"Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius","volume":"80","author":"Bell","year":"1998","journal-title":"J\u00a0Bone Joint Surg Br"},{"issue":"2","key":"10.1016\/j.jhsa.2023.04.021_bib14","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.main.2009.12.005","article-title":"Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases","volume":"29","author":"Valbuena","year":"2010","journal-title":"Chir Main"},{"issue":"6","key":"10.1016\/j.jhsa.2023.04.021_bib15","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1016\/j.jhsa.2013.03.011","article-title":"Volar plate position and flexor tendon rupture following distal radius fracture fixation","volume":"38","author":"Kitay","year":"2013","journal-title":"J\u00a0Hand Surg Am"},{"issue":"3","key":"10.1016\/j.jhsa.2023.04.021_bib16","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.jhsa.2015.11.022","article-title":"Ultrasonic evaluation of the flexor pollicis longus tendon following volar plate fixation for distal radius fractures","volume":"41","author":"Kara","year":"2016","journal-title":"J\u00a0Hand Surg Am"},{"issue":"1","key":"10.1016\/j.jhsa.2023.04.021_bib17","doi-asserted-by":"crossref","first-page":"e104","DOI":"10.3928\/01477447-20161017-01","article-title":"Ultrasonographic assessment of the flexor pollicis longus tendon after plate fixation","volume":"40","author":"Kadoma","year":"2017","journal-title":"Orthopedics"},{"issue":"10","key":"10.1016\/j.jhsa.2023.04.021_bib18","doi-asserted-by":"crossref","first-page":"2785","DOI":"10.1002\/jum.14968","article-title":"Ultrasound evaluation of the protector role of the pronator quadratus suture in volar plating","volume":"38","author":"Walch","year":"2019","journal-title":"J\u00a0Ultrasound Med"},{"issue":"1","key":"10.1016\/j.jhsa.2023.04.021_bib19","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1142\/S0218810417500137","article-title":"Asymptomatic flexor tendon damages after volar locking plate fixation of distal radius fractures","volume":"22","author":"Tokunaga","year":"2017","journal-title":"J\u00a0Hand Surg Asian-Pac Vol"},{"issue":"1","key":"10.1016\/j.jhsa.2023.04.021_bib20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12891-020-03450-8","article-title":"Do we need to suture the pronator quadratus muscle when we do open reduction and internal fixation for fracture of the distal radius","volume":"21","author":"Fang","year":"2020","journal-title":"BMC Musculoskelet Disord"},{"issue":"3","key":"10.1016\/j.jhsa.2023.04.021_bib21","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.hansur.2017.12.008","article-title":"Ultrasonographic evaluation of the distance between the flexor pollicis longus tendon and volar prominence of the plate as a function of volar plate positioning and pronator quadratus repair\u2014A cadaver study","volume":"37","author":"Goorens","year":"2018","journal-title":"Hand Surg Rehabil"}],"container-title":["The Journal of Hand Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0363502323002551?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0363502323002551?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T09:16:40Z","timestamp":1735723000000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0363502323002551"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,1]]}},"alternative-id":["S0363502323002551"],"URL":"https:\/\/doi.org\/10.1016\/j.jhsa.2023.04.021","relation":{},"ISSN":["0363-5023"],"issn-type":[{"value":"0363-5023","type":"print"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Changes in Distance Between the Flexor Pollicis Longus Tendon and Volar Locking Plate: An Ultrasonographic Study","name":"articletitle","label":"Article Title"},{"value":"The Journal of Hand Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jhsa.2023.04.021","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 by the American Society for Surgery of the Hand.","name":"copyright","label":"Copyright"}]}}